Hypoperfusion in nucleus accumbens in chronic migraine using 3D pseudo-continuous arterial spin labeling imaging MRI

被引:9
|
作者
Liu, Mengqi [1 ,2 ]
Sun, Yijie [1 ]
Li, Xin [1 ,3 ]
Chen, Zhiye [1 ,3 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Hainan Hosp, Dept Radiol, Sanya 572013, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Radiol, Beijing 100853, Peoples R China
[3] Southern Med Univ, Sch Clin Med 2, Guangzhou 510515, Peoples R China
来源
JOURNAL OF HEADACHE AND PAIN | 2022年 / 23卷 / 01期
关键词
Arterial spin labelling; Brain; Chronic migraine; Magnetic resonance imaging; Nucleus accumbens; Perfusion imaging; CEREBRAL PERFUSION; PAIN; BRAIN; INVOLVEMENT; VOLUME;
D O I
10.1186/s10194-022-01444-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Nucleus accumbens (NAcc) played an important role in pain mediation, and presents changes of neuronal plasticity and functional connectivity. However, less is known about altered perfusion of NAcc in chronic migraine (CM). The aim of this study is to investigate the altered perfusion of the NAcc in CM using a MR three-dimensional pseudo-continuous arterial spin labeling (3D PCASL) imaging. Methods Thirteen CM patients and 15 normal controls (NC) were enrolled and underwent 3D PCASL and brain structural imaging. The cerebral blood flow (CBF) images were co-registered with the brain structural images, and the volume and CBF value of NAcc were extracted from the raw brain structural images and co-registered CBF images using an individual NAcc mask, which was obtained from the AAL3 template under transformation by the inverse deformation field generated from the segmentation of the brain structural images. The independent sample t test and receiver operating characteristic (ROC) curve was used to investigate the altered volume and perfusion of the NAcc in CM patients. Results There was no significant difference for the volume of bilateral NAccs between CM and NC (p > 0.05). CM presented a lower CBF value (49.34 +/- 6.09 ml/100 mg/min) compared with that of NC (55.83 +/- 6.55 ml/100 mg/min) in left NAcc (p = 0.01), while right NAcc showed no significant difference between CM and NC (p = 0.11). ROC analysis identified that the area under the curve was 0.73 (95CI% 0.53-0.88) with cut-off value 48.63 ml/100 mg/min with sensitivity 50.00% and specificity 93.33%. The correlation analysis found a negative correlation between the CBF value of the left NAcc and VAS score (r = -0.61, p = 0.04). Conclusion Hypoperfusion of the left NAcc was observed in CM, which could be considered as a potential diagnostic imaging biomarker in CM.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] 3D time-resolved vessel-selective angiography based on pseudo-continuous arterial spin labeling
    Lindner, Thomas
    Jensen-Kondering, Ulf
    van Osch, Matthias J. P.
    Jansen, Olav
    Helle, Michael
    MAGNETIC RESONANCE IMAGING, 2015, 33 (06) : 840 - 846
  • [32] A longitudinal study of cerebral blood flow under hypoxia at high altitude using 3D pseudo-continuous arterial spin labeling
    Liu, Wenjia
    Liu, Jie
    Lou, Xin
    Zheng, Dandan
    Wu, Bing
    Wang, Danny J. J.
    Ma, Lin
    SCIENTIFIC REPORTS, 2017, 7
  • [33] Characterization of Pseudo-Continuous Arterial Spin Labeling: Simulations and Experimental Validation
    Lorenz, Kathrin
    Mildner, Toralf
    Schlumm, Torsten
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1638 - 1649
  • [34] Inter-Vendor Reproducibility of Pseudo-Continuous Arterial Spin Labeling at 3 Tesla
    Mutsaerts, Henri J. M. M.
    Steketee, Rebecca M. E.
    Heijtel, Dennis F. R.
    Kuijer, Joost P. A.
    van Osch, Matthias J. P.
    Majoie, Charles B. L. M.
    Smits, Marion
    Nederveen, Aart J.
    PLOS ONE, 2014, 9 (08):
  • [35] Cerebral Blood Flow Quantification in Swine Using Pseudo-Continuous Arterial Spin Labeling
    Johnston, Megan E.
    Zheng, Zhenlin
    Maldjian, Joseph A.
    Whitlow, Christopher T.
    Morykwas, Michael J.
    Jung, Youngkyoo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (05) : 1111 - 1118
  • [36] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    Johan N. van der Meer
    Dennis F. R. Heijtel
    Guus van Hest
    Geert-Jan Plattèl
    Matthijs J. P. van Osch
    Eus J. W. van Someren
    Ed T. vanBavel
    Aart J. Nederveen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 269 - 276
  • [37] Improved Pseudo-Continuous Arterial Spin Labeling for Mapping Brain Perfusion
    Nezamzadeh, Marzieh
    Matson, Gerald B.
    Young, Karl
    Weiner, Michael W.
    Schuff, Norbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (06) : 1419 - 1427
  • [38] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    van der Meer, Johan N.
    Heijtel, Dennis F. R.
    van Hest, Guus
    Plattel, Geert-Jan
    van Osch, Matthijs J. P.
    van Someren, Eus J. W.
    vanBavel, Ed T.
    Nederveen, Aart J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (03) : 269 - 276
  • [39] Can 3D pseudo-continuous arterial spin labeling perfusion imaging be applied to predict early response to chemoradiotherapy in patients with advanced nasopharyngeal carcinoma?
    Sun, Zongqiong
    Hu, Shudong
    Xue, Qian
    Jin, Linfang
    Huang, Jianfeng
    Dou, Weiqiang
    RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 97 - 106
  • [40] Editorial for "Can 3D Pseudo-Continuous Territorial Arterial Spin Labeling Diagnose Unilateral Middle Cerebral Artery Stenosis?"
    Fernandes, Joao Filipe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (01) : 184 - 185