Evaluation of real-time imaging using a laparoscopic ultrasound probe during operative endoscopic procedures

被引:18
|
作者
Letterie, GS [1 ]
Marshall, L [1 ]
机构
[1] Virginia Mason Med Ctr, Ctr Fertil & Reprod Endocrinol, Seattle, WA 98110 USA
关键词
endoscopic ultrasound; hysteroscopy; laparoscopy;
D O I
10.1046/j.1469-0705.2000.00172.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To evaluate rigid and flexible ultrasound transducers introduced through a laparoscopic port to image pelvic anatomy during operative endoscopy as a means of mapping the pelvic anatomy, detecting pathology, and for real-time tracking of intra-uterine procedures. Design Prospective, descriptive, non-comparative. Materials and methods Laparoscopy, hysteroscopy and real-time, gray-scale ultrasonography were preformed simultaneously in 36 patients. Laparoscopic ultrasound was performed using 10 mm diameter, 7.5 MHz gray-scale rigid and steerable transducers for imaging of the ovaries and uterus during operative endoscopy (Aloka, Wallingford, CT, USA). All patients underwent intra-operative evaluation using this probe to assess uterine and ovarian structures and to track instruments intra-operatively during complex intra-uterine hysteroscopic procedures and for intra-operative sonohysterography. Results Laparoscopic ultrasound provided visualization of structures and delineation of ovarian anatomy needle placement for tracking microscissors and intra-operative sonohysterography. The ultrasonography provided information useful for determining the configuration of normal anatomic structures, the localization of and more precise incision placement for anatomic abnormalities and for intra-operative guidance during hysteroscopic resection of intra-uterine adhesions. The imaging also provided details of intra-uterine anatomy through sonohysterography performed during chromotubation. However, no additional information regarding ovarian or uterine abnormalities was noted beyond that detected on pre-operative transvaginal ultrasonography. No technical problems were encountered. No additional operative time was required. Conclusions Real-time laparoscopic ultrasound imaging is useful in monitoring complex intra-uterine operative procedures and in detailing intra-uterine anatomy during intra-operative sonohysterography. However, it did not provide more enhanced imaging of ovarian anatomy beyond images obtained with pre-operative transvaginal imaging. This imaging technique may have broad application for a variety of endoscopic operative procedures with the potential to impact on operative decision-making and requires further evaluation.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 50 条
  • [41] New real-time strain imaging concepts using diagnostic ultrasound
    Pesavento, A
    Lorenz, A
    Siebers, S
    Ermert, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06): : 1423 - 1435
  • [42] Real-time volumetric ultrasound imaging using free hand scanning
    Nikolaev, Anton
    Hansen, Hendrik H. G.
    de Korte, Chris L.
    MEDICAL IMAGING 2018: ULTRASONIC IMAGING AND TOMOGRAPHY, 2018, 10580
  • [43] Noninvasive real-time imaging of atherosclerosis in mice using ultrasound biomicroscopy
    Gan, LM
    Grönros, J
    Hägg, U
    Wilkström, J
    Fritsche-Danielsson, R
    CIRCULATION, 2004, 110 (17) : 374 - 375
  • [44] THE USE OF REAL-TIME ULTRASOUND AS AN AID DURING DIFFICULT THERAPEUTIC-ABORTION PROCEDURES
    GOLDENBERG, RL
    DAVIS, RO
    HILL, D
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (06) : 826 - 827
  • [45] TONGUE MOVEMENT DURING SPEECH AND SWALLOWING - A REAL-TIME ULTRASOUND EVALUATION
    SHAWKER, TH
    SONIES, BC
    HALL, TE
    ULTRASONIC IMAGING, 1982, 4 (02) : 183 - 184
  • [46] Real-Time 2-D Temperature Imaging Using Ultrasound
    Liu, Dalong
    Ebbini, Emad S.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) : 12 - 16
  • [47] Effect of ultrasound probe on dose delivery during real-time ultrasound-guided tumor tracking
    Wu, Jianzhou
    Dandekar, Omkar
    Nazareth, Daryl
    Lei, Peng
    D'Souza, Warren
    Shekhar, Raj
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4430 - +
  • [48] Evaluation of intrafractional prostate displacement during prostate radiotherapy using real-time ultrasound system
    Nur Syazana Mohd Zahir
    Marniza Saad
    Adlinda Alip
    Munira Rejab
    Zulaikha Jamalludin
    Nur Diyana Afrina Hizam
    Yih Miin Liew
    Ngie Min Ung
    Physical and Engineering Sciences in Medicine, 2023, 46 : 405 - 412
  • [49] Evaluation of intrafractional prostate displacement during prostate radiotherapy using real-time ultrasound system
    Zahir, Nur Syazana Mohd
    Saad, Marniza
    Alip, Adlinda
    Rejab, Munira
    Jamalludin, Zulaikha
    Hizam, Nur Diyana Afrina
    Liew, Yih Miin
    Ung, Ngie Min
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 405 - 412
  • [50] EVALUATION OF A REAL-TIME ULTRASOUND IMAGING-SYSTEM FOR CAROTID-ARTERY
    ACKERMAN, RH