摘要
The present study was aimed at measuring the haemoglobin oxygen saturation and the pulse rate on dairy cow teats before and after milking, using a bespoke low-cost pulse oximeter. The pulse oximeter was tested in a three-day field test involving 18 Holstein Friesian cows raised in a commercial farm located in Northern Italy. The results highlighted a significant difference both in haemoglobin oxygen saturation (SpO(2)) and pulse rate before and after milking in the entire sample of animals. By dividing the sample according to the milking time (fast <8 min and slow >8 min), a significant difference between fast and slow cows was observed for SpO(2), whilst no difference was identified in relation to their lactation stage [<70 days in milking (DIM) and 71-140 DIM]. As to the pulse rate, milking time and lactation stage were not significantly different. This confirms that machine milking can create stress to the teat causing tissue circulatory impairment and pulse oximetry could be useful for detecting machine milking-induced alterations of teats. In the future, the pulse oximeter could be used as part of a milking machine monitoring system in order to change operating parameters to minimize the mechanical stress on the teats.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Evaluation of Pulse Rate, Oxygen Saturation, and Respiratory Effort after Different Types of Feeding Methods in Preterm Newborns
    Patel, Dipen Vasudev
    Shah, Dharti
    Kantharia, Kunjal A.
    Shinde, Mayur K.
    Ganjiwale, Jaishree
    Shah, Kushal
    Nimbalkar, Somashekhar Marutirao
    [J]. INTERNATIONAL JOURNAL OF PEDIATRICS, 2022, 2022
  • [42] Pulse shape discrimination with a low-cost digitizer using commercial off-the-shelf components
    Recker, M. C.
    Cazalas, E. J.
    McClory, J. W.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954 (954):
  • [43] Simple Digital Pulse Width Modulator with 60 Picoseconds Resolution Using a Low-cost FPGA
    Costinett, Daniel
    Rodriguez, Miguel
    Maksimovic, Dragan
    [J]. 2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [44] Low-Cost and Portable Device to Monitor Heart Rate, Blood Oxygen Saturation and Body Temperature with Warning System
    Guo, Cong
    Ma, Qianhui
    Shen, Mingyu
    Dong, Xinghao
    Chen, Shuaifei
    Liu, Fulong
    [J]. PROCEEDINGS OF TEPEN 2022, 2023, 129 : 641 - 652
  • [45] X-RAY TRANSMISSION-RATE-MEASURING BY USING LOW-COST LABORATORY COUNTER
    Zengin, Aydin Tarik
    [J]. JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2021, 16 (01): : 52 - 64
  • [46] Low-cost analog signal generation using a pulse-density modulated digital ATE channel
    Rivoir, J
    [J]. 13TH ASIAN TEST SYMPOSIUM, PROCEEDINGS, 2004, : 290 - 295
  • [47] Low-cost and efficient digital-compatible BIST for analog circuits using pulse response sampling
    Variyam, PN
    Chatterjee, A
    Nagi, N
    [J]. 15TH IEEE VLSI TEST SYMPOSIUM, PROCEEDINGS, 1997, : 261 - 266
  • [48] Prediction of low pulse oxygen saturation in COVID-19 using remote monitoring post hospital discharge
    Doheny, Emer P.
    Flood, Matthew
    Ryan, Silke
    McCarthy, Cormac
    'Carroll, Orla
    'Seaghdha, Conall
    Mallon, Patrick W.
    Feeney, Eoin R.
    Keatings, Vera M.
    Wilson, Moya
    Kennedy, Niall
    Gannon, Avril
    Edwards, Colin
    Lowery, Madeleine M.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2023, 169
  • [49] A heat-pulse method for measuring sap flow in corn and sunflower using 3D-printed sensor bodies and low-cost electronics
    Miner, Grace Lloyd
    Ham, Jay M.
    Kluitenberg, Gerard J.
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 2017, 246 : 86 - 97
  • [50] Characterization of the emission behavior of pulse-jet cleaned filters using a low-cost particulate matter sensor
    Baechler, P.
    Meyer, J.
    Dittler, A.
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (11-12): : 443 - 450