Measuring oxygen saturation and pulse rate in dairy cows before and after machine milking using a low-cost pulse oximeter

被引:0
|
作者
Calcante, Aldo [1 ]
Tangorra, Francesco M. [2 ]
机构
[1] Univ Milan, Dept Agr & Environm Sci, Via Celoria 2, I-20133 Milan, Italy
[2] Univ Milan, Dept Vet Sci Hlth Anim Prod & Food Safety, Milan, Italy
来源
JOURNAL OF AGRICULTURAL ENGINEERING | 2021年 / 52卷 / 02期
关键词
Dairy cows; haemoglobin oxygen saturation; machine milking; pulse oximeter; pulse rate; TEAT-END; THICKNESS;
D O I
10.4081/jae.2021.1155
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The present study was aimed at measuring the haemoglobin oxygen saturation and the pulse rate on dairy cow teats before and after milking, using a bespoke low-cost pulse oximeter. The pulse oximeter was tested in a three-day field test involving 18 Holstein Friesian cows raised in a commercial farm located in Northern Italy. The results highlighted a significant difference both in haemoglobin oxygen saturation (SpO(2)) and pulse rate before and after milking in the entire sample of animals. By dividing the sample according to the milking time (fast <8 min and slow >8 min), a significant difference between fast and slow cows was observed for SpO(2), whilst no difference was identified in relation to their lactation stage [<70 days in milking (DIM) and 71-140 DIM]. As to the pulse rate, milking time and lactation stage were not significantly different. This confirms that machine milking can create stress to the teat causing tissue circulatory impairment and pulse oximetry could be useful for detecting machine milking-induced alterations of teats. In the future, the pulse oximeter could be used as part of a milking machine monitoring system in order to change operating parameters to minimize the mechanical stress on the teats.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Design of a Low-cost Pulse Oximeter
    Gao, Xiaoming
    You, Xia
    [J]. PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 909 - 913
  • [2] BUCCAL PULSE OXIMETER IS MORE ACCURATE THAN FINGER PULSE OXIMETER IN MEASURING OXYGEN-SATURATION
    OLEARY, RJ
    LANDON, M
    BENUMOF, JL
    [J]. ANESTHESIA AND ANALGESIA, 1992, 75 (04): : 495 - 498
  • [3] Design and Evaluation of a Low-Cost Smartphone Pulse Oximeter
    Petersen, Christian L.
    Chen, Tso P.
    Ansermino, J. Mark
    Dumont, Guy A.
    [J]. SENSORS, 2013, 13 (12): : 16882 - 16893
  • [4] Low cost Pulse Oximeter using Arduino
    Castellanos Carcamo, Amanda Aracely
    Majano Reyes, Merlin Guadalupe
    Sanchez Urbina, Sophia Mariella
    [J]. 2019 IEEE CHILEAN CONFERENCE ON ELECTRICAL, ELECTRONICS ENGINEERING, INFORMATION AND COMMUNICATION TECHNOLOGIES (CHILECON), 2019,
  • [5] Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves
    Kanz, P.
    Krieger, S.
    Drillich, M.
    Iwersen, M.
    [J]. JOURNAL OF DAIRY SCIENCE, 2018, 101 (07) : 6437 - 6442
  • [6] Evaluation of a wireless pulse oximeter for measuring the arterial oxygen saturation and pulse frequency in Holstein Friesian calves
    Kanz, P.
    Iwersen, M.
    Krieger, S.
    Drillich, M.
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2018, 53 : 20 - 20
  • [7] Development of a low-cost pulse oximeter simulator for educational purposes
    Machado-Gamboa, Kevin
    Gonzalez-Vargas, Andres
    [J]. 2018 IEEE ANDESCON, 2018,
  • [8] Evaluation of a New Smartphone Powered Low-cost Pulse Oximeter Device
    Nemomssa, Hundessa Daba
    Raj, Hakkins
    [J]. ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2022, 32 (04) : 841 - 848
  • [9] ANALYSIS OF HEART RATE AND OXYGEN SATURATION USING PULSE OXIMETER BETWEEN MALE AND FEMALE AT HYDERABAD PAKISTAN
    Ali, Muhammad
    [J]. JOURNAL OF HYPERTENSION, 2021, 39 : E175 - E176
  • [10] THE EFFECT OF THE INHALATION OF HIGH AND LOW OXYGEN CONCENTRATIONS ON RESPIRATION, PULSE RATE, BALLISTOCARDIOGRAM AND ARTERIAL OXYGEN SATURATION (OXIMETER) OF NORMAL INDIVIDUALS
    DRIPPS, RD
    COMROE, JH
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1947, 149 (02): : 277 - 291