Trapping, separating, and palpating microbead clusters in droplets and flows using capacitive micromachined ultrasonic transducers (CMUTs)

被引:9
|
作者
Samarasekera, Champika [1 ]
Sun, Jame G. W. [2 ,3 ]
Zheng, Zhou [1 ]
Yeow, John T. W. [1 ]
机构
[1] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
[2] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON, Canada
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Acoustophoresis; Acoustofluidics; Actuators; Agglomeration; CMUT; Microfluidics; Separation; ACOUSTIC RADIATION FORCE; STANDING-WAVE; DIELECTROPHORETIC SEPARATION; CELLS; PARTICLES; MANIPULATION; MICROPARTICLES; MICROSPHERES; SENSITIVITY; RESONATORS;
D O I
10.1016/j.snb.2018.08.085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bead-based assays are incredibly popular in clinical and pharmacological settings for detecting single or multiple analytes. Separating and trapping beads are often integral steps, especially when such assays are conducted in microfluidic environments. Here, we report a first instance of the use of a capacitive micromachined ultrasonic transducer (CMUT) microarray for acoustically trapping silica beads within droplets into discrete, well-formed, circular clusters. We then demonstrate that the expansion and contraction of these clusters may be regulated via adjustments to the CMUT driving frequency. To our knowledge, this palpating action of aggregates has not been reported in other non-contact techniques. Bead manipulations are also replicated in a microchannel against flows with fluid velocities of 1.9 +/- 0.2 mm s(-1). The laminar flow conditions are exploited to sequentially trap bead clusters or separate large populations of beads into discrete streams by operating the CMUT microarray at threshold voltages. Unlike piezoelectric materials, CMUTs offer superior miniaturization through well established microfabrication techniques, better acoustic matching to fluids, and lower risk of sample heating. Thus, we believe this work illustrates the versatility of CMUT microarrays for use in future bead-based assays in lab-ona-chip (LOC) platforms.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 50 条
  • [21] Integral Sliding Mode Based Optimal Composite Nonlinear Feedback Control for Capacitive Micromachined Ultrasonic Transducers (CMUTs) System
    Qin, Yi
    Sun, Weijie
    Yeow, John T. W.
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 1323 - 1328
  • [22] The Design and Characterization of Capacitive Micromachined Ultrasonic Transducers (CMUTs) for Generating High-Intensity Ultrasound for Transmission of Directional Audio
    Wygant, Ira O.
    Kupnik, Mario
    Khuri-Yakub, Butrus T.
    Wochner, Mark S.
    Wright, Wayne M.
    Hamilton, Mark F.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 2100 - +
  • [23] Noninvasive Fluid Flowrate Detection Using Capacitive Micromachined Ultrasonic Transducers
    Yuan, Jiawei
    Li, Zixuan
    Ma, Qi
    Qin, Shaohui
    Shi, Xuan
    Yuan, Zheng
    Zhao, Yihe
    Wang, Xiaozhang
    Li, Zhikang
    Zhao, Libo
    2024 IEEE 19TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, NEMS 2024, 2024,
  • [24] Capacitive micromachined ultrasonic lamb wave transducers using rectangular membranes
    Badi, MH
    Yaralioglu, GG
    Ergun, AS
    Hansen, ST
    Wong, EJ
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (09) : 1191 - 1203
  • [25] Micromachined capacitive ultrasonic transducers fabricated using silicon on insulator wafers
    Cianci, E
    Foglietti, V
    Caliano, G
    Pappalardo, M
    MICROELECTRONIC ENGINEERING, 2002, 61-2 : 1025 - 1029
  • [26] Characterization of capacitive micromachined ultrasonic transducers in air using optical measurements
    Hansen, ST
    Turo, A
    Degertekin, FL
    Khuri-Yakub, BT
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 947 - 950
  • [27] Acoustic sensing using radio micromachined frequency detection and capacitive ultrasonic transducers
    Hansen, ST
    Ergun, AS
    Khuri-Yakub, BT
    2001 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2001, : 2243 - 2246
  • [28] Acoustic Energy Transfer through Skin Using Capacitive Micromachined Ultrasonic Transducers
    Roche, Paul
    Nadaud, Kevin
    Poulin-Vittrant, Guylaine
    Calle, Samuel
    Certon, Dominique
    Le Bunetel, Jean-Charles
    2024 10TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND ROBOTICS ENGINEERING, ICMRE, 2024, : 209 - 212
  • [29] Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers
    Oygard, Sigrid Husebo
    Ommen, Martin Lind
    Tomov, Borislav Gueorguiev
    Diederichsen, Soren Elmin
    Thomsen, Erik Vilain
    Stuart, Matthias Bo
    Larsen, Niels Bent
    Jensen, Jorgen Arendt
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03): : 1887 - 1897
  • [30] Fabrication of embossed capacitive micromachined ultrasonic transducers using sacrificial release process
    Yu, Yuanyu
    Wang, Jiujiang
    Pun, Sio Hang
    Cheng, Ching-Hsiang
    Lei, Kin Fong
    Vai, Mang, I
    Zhang, Shuang
    Mak, Peng Un
    IEICE ELECTRONICS EXPRESS, 2019, 16 (02):