Real-time dosimetry reduces radiation exposure of orthopaedic surgeons

被引:20
|
作者
Mueller, M. C. [1 ]
Welle, K. [1 ]
Strauss, A. [1 ]
Naehle, P. C. [2 ]
Pennekamp, P. H. [1 ]
Weber, O. [3 ]
Burger, C. [1 ]
机构
[1] Univ Hosp Bonn, Dept Orthopaed & Trauma Surg, D-53105 Bonn, Germany
[2] Univ Hosp Bonn, Dept Radiol, D-53105 Bonn, Germany
[3] St Martinus Hosp Olpe, Dept Orthopaed Trauma & Hand Surg, D-57462 Olpe, Germany
关键词
Occupational exposure; Radiation; Orthopaedic surgery; Dosimetry; INTERVENTIONAL RADIOLOGY; IONIZING-RADIATION; BREAST-CANCER; RISK; FLUOROSCOPY; PREVALENCE; FRACTURES;
D O I
10.1016/j.otsr.2014.09.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cancer prevalence of orthopaedic surgeons is elevated and chronic exposure to occupational ionizing radiation is seen as one reason. Hypothesis: Use of a new dosimeter enabling radiation dose monitoring in real-time may reduce radiation exposure of orthopaedic surgeons. Materials and methods: Over a period of four months, the surgeon and the C-arm operator were equipped with a novel dosimeter called DoseAware (R) (DA) while using the C-arm fluoroscope intraoperatively. Data of 68 patients DA were retrospectively compared using matched-pair analysis with 68 controls without DA. Both groups were assessed regarding fluoroscopic time (FT) and radiation dose (RD). Seven types of operative procedures were performed: internal fixation of subcapital humerus fractures, midshaft clavicular fractures, distal radius fractures, pertrochanteric femoral fractures, ankle fractures, traumatic vertebral fractures and osteoporotic vertebral fractures. Results: Concerning the FT, use of DoseAware (R) led to a significant reduction for all evaluated operation types except for internal fixation of distal radius fractures (P=0.0511). Regarding the RD, use of DoseAware (R) led to a significant reduction for all evaluated operation types except trochanteric femoral fractures with a PFNA (R) (P= 0.0841). Conclusion: DoseAware (R) allowing real-time radiation dose monitoring reduces radiation exposure of the orthopaedic surgeon and instantly demonstrates the effects of dose-reduction techniques. Level of evidence: Level III retrospective case control study. (C) 2014 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:947 / 951
页数:5
相关论文
共 50 条
  • [1] Radiation Exposure of Anaesthetists Visualised by Real-time Dosimetry
    Mueller, Marcus Christian
    Windemuth, Michael
    Frege, Sophie
    Striepens, Eva Nadine
    CURRENT MEDICAL IMAGING, 2019, 15 (02) : 220 - 226
  • [2] Reduction of Radiation Exposure From C-Arm Fluoroscopy During Orthopaedic Trauma Operations With Introduction of Real-Time Dosimetry
    Baumgartner, Rita
    Libuit, Kiley
    Ren, Dennis
    Bakr, Omar
    Singh, Nathan
    Kandemir, Utku
    Marmor, Meir Tibi
    Morshed, Saam
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (02) : E53 - E58
  • [3] Evaluation of Radiation Exposure of Personnel in an Orthopaedic and Trauma Operation Theatre Using the New Real-Time Dosimetry System "Dose Aware"
    Mueller, M. C.
    Strauss, A.
    Pflugmacher, R.
    Naehle, C. P.
    Pennekamp, P. H.
    Burger, C.
    Wirtz, D. C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2014, 152 (04): : 381 - 388
  • [4] Orthopaedic section - Risks of radiation exposure to orthopaedic surgeons
    ORourke, PJ
    Crerand, S
    Harrington, P
    Casey, M
    Quinlan, W
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 1996, 41 (01): : 40 - 43
  • [5] Effects of Real-Time Dosimetry on Staff Radiation Exposure in the Cardiac Catheterization Laboratory
    Murat, Dilschad
    Wilken-Tergau, Christian
    Gottwald, Uta
    Nemitz, Ole
    Uher, Thomas
    Schulz, Eberhard
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (05): : E337 - E341
  • [6] Examination of the real-time exposure dosimetry system using synthetic ruby on the radiation therapy
    Maruyama, A.
    Yamaguchi, T.
    Ono, D.
    Kikuchi, T.
    Kikuchi, Y.
    Sato, R.
    Watanabe, S.
    Hosokai, Y.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S916 - S917
  • [7] Characteristics of a real-time radiation exposure dosimetry system using a synthetic ruby for radiotherapy
    Kenki Matsumoto
    Ayaka Maruyama
    Satoru Watanabe
    Ryousuke Tachibana
    Toshiya Yamaguchi
    Kouki Suzuki
    Yoshiki Kurihara
    Masayoshi Maehara
    Satoshi Arakawa
    Yoshiyuki Hosokai
    Radiological Physics and Technology, 2023, 16 : 69 - 76
  • [8] Real-Time Dosimetry Measurements Reduce Surgeon Radiation Exposure During Endovascular Procedures
    Lu, Patricia G.
    Sheaffer, William
    Pierce, Austin
    Stone, William
    Davila, Victor
    Soh, Ina
    Meltzer, Andrew
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : E97 - E97
  • [9] Characteristics of a real-time radiation exposure dosimetry system using a synthetic ruby for radiotherapy
    Matsumoto, Kenki
    Maruyama, Ayaka
    Watanabe, Satoru
    Tachibana, Ryousuke
    Yamaguchi, Toshiya
    Suzuki, Kouki
    Kurihara, Yoshiki
    Maehara, Masayoshi
    Arakawa, Satoshi
    Hosokai, Yoshiyuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (01) : 69 - 76
  • [10] Radiation Exposure and Health Risks for Orthopaedic Surgeons
    Hayda, Roman A.
    Hsu, Raymond Y.
    DePasse, J. Mason
    Gil, Joseph A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2018, 26 (08) : 268 - 277