Intraindividual In Vivo Comparison of Gadolinium Contrast Agents for Pharmacokinetic Analysis Using Dynamic Contrast Enhanced Magnetic Resonance Imaging

被引:17
|
作者
Liang, Jiachao [1 ]
Sammet, Steffen [1 ]
Yang, Xiangyu [1 ]
Jia, Guang [1 ]
Takayama, Yukihisa [1 ]
Knopp, Michael V. [1 ]
机构
[1] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
contrast agent; DCE-MRI; gadobenate dimeglumine; 7T; crossover comparison; DIMEGLUMINE GD-BOPTA; ARTERIAL INPUT FUNCTION; GADOBENATE DIMEGLUMINE; GADOPENTETATE DIMEGLUMINE; DCE-MRI; KINETIC-PARAMETERS; BRAIN; DTPA; BREAST; MEDIA;
D O I
10.1097/RLI.0b013e3181d54507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the intraindividual differences of dynamic signal characteristics for 3 gadolinium chelates (gadopentetate dimeglumine [Gd-DTPA], gadodiamide [Gd-DTPA-BMA], and gadobenate dimeglumine [Gd-BOPTA]) using dynamic contrast enhanced magnetic resonance (MR) imaging (DCE-MRI) with a preclinical beagle model at 7 Tesla. Method and Materials: Seven beagles were scanned 3 times each with a 7-day interval between the scans on a 7T whole body MRI system (Achieva, Philips) using a T/R head coil. Three different Gd contrast agents including Gd-DTPA, Gd-DTPABMA, and Gd-BOPTA were injected in a randomized order with a power injector (Spectris, MedRad, Indianola, PA) using dose of 0.1 mmol/kg body weight and flow rate of 0.06 mL/s. During image acquisition and data analysis, the identity of the specific contrast agent used for each examination was blinded. A 3D RF-spoiled fast field echo sequence was used for dynamic scans with in-plane spatial resolution 0.47 x 0.47 mm2, temporal resolution of 9.5 seconds, and a total of 60 time points. Regions of interest were drawn within the carotid arteries and muscle tissue to determine semiquantitative parameters including maximum enhancement ratio, area under the signal enhancement curve over 90 seconds after contrast injection (AUC_90), time to maximum signal enhancement (T-max), and washout_score. Additionally, quantitative pharmacokinetic parameters were measured in muscle tissues by applying 3 separate 2-compartment models; (1) artery input function (AIF) based Tofts model, (2) Brix model without AIF, and (3) AIF decomposed refined Brix model. Results: Gd-BOPTA produced higher signal to noise ratio on postcontrast T1-weighted images than the other 2 Gd based contrast agents at 7T. Quantitatively, Gd-BOPTA provided a significantly higher maximum enhancement ratio (P < 0.01), AUC_90 (P < 0.01) and washout_score (P < 0.01) in beagle musculature and cranial vasculature compared with both Gd-DTPA and Gd-DTPA-BMA. Among all the quantitative pharmacokinetic parameters, only the exchange rate constants (kep) calculated from these 3 models did not show a significant difference among the various contrast agents. Conclusions: Gd chelate containing MR contrast agents can be used at 7T for DCEMRI. Gd-BOPTA demonstrates stronger signal enhancement than standard Gd chelates, in concordance with the results of studies at lower fields. The observed enhancement characteristics for the 3 contrast agents demonstrate that the pharmacokinetic parameter kep is more robust in various models using DCE-MRI than the other pharmacokinetic parameters. This information is important relative to multisite clinical trials and long-term clinical studies that often use several different contrast agents and different models.
引用
收藏
页码:233 / 244
页数:12
相关论文
共 50 条
  • [31] Bayesian pharmacokinetic modeling of dynamic contrast-enhanced magnetic resonance imaging: validation and application
    Mittermeier, Andreas
    Ertl-Wagner, Birgit
    Ricke, Jens
    Dietrich, Olaf
    Ingrisch, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [32] Intra-individual comparison of different gadolinium-based contrast agents in the quantitative evaluation of C6 glioma with dynamic contrast-enhanced magnetic resonance imaging
    Ying Li
    Gang Liu
    Xin Lou
    Zhiye Chen
    Lin Ma
    Science China(Life Sciences), 2017, (01) : 11 - 15
  • [33] Intra-individual comparison of different gadolinium-based contrast agents in the quantitative evaluation of C6 glioma with dynamic contrast-enhanced magnetic resonance imaging
    Ying Li
    Gang Liu
    Xin Lou
    Zhiye Chen
    Lin Ma
    Science China(Life Sciences), 2017, 60 (01) : 11 - 15
  • [34] Intra-individual comparison of different gadolinium-based contrast agents in the quantitative evaluation of C6 glioma with dynamic contrast-enhanced magnetic resonance imaging
    Ying Li
    Gang Liu
    Xin Lou
    Zhiye Chen
    Lin Ma
    Science China Life Sciences, 2017, 60 : 11 - 15
  • [35] Intra-individual comparison of different gadolinium-based contrast agents in the quantitative evaluation of C6 glioma with dynamic contrast-enhanced magnetic resonance imaging
    Li, Ying
    Liu, Gang
    Lou, Xin
    Chen, Zhiye
    Ma, Lin
    SCIENCE CHINA-LIFE SCIENCES, 2017, 60 (01) : 11 - 15
  • [36] Evolution from empirical dynamic contrast-enhanced magnetic resonance imaging to pharmacokinetic MRI
    Taylor, JS
    Reddick, WE
    ADVANCED DRUG DELIVERY REVIEWS, 2000, 41 (01) : 91 - 110
  • [37] Simple Method for Quantification of Gadolinium Magnetic Resonance Imaging Contrast Agents Using ESR Spectroscopy
    Takeshita, Keizo
    Kinoshita, Shota
    Okazaki, Shoko
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2012, 60 (01) : 31 - 36
  • [38] Contrast agents in magnetic resonance imaging
    Dawson, P
    EUROPEAN JOURNAL OF RADIOLOGY, 1996, 23 (03) : 201 - 204
  • [39] Studies on polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents
    Yan, Guo-Ping
    Liu, Mai-Li
    Li, Li-Yun
    RADIOGRAPHY, 2005, 11 (02) : 117 - 122
  • [40] Gadolinium-Loaded Viral Capsids as Magnetic Resonance Imaging Contrast Agents
    Robert J. Usselman
    Shefah Qazi
    Priyanka Aggarwal
    Sandra S. Eaton
    Gareth R. Eaton
    Stephen Russek
    Trevor Douglas
    Applied Magnetic Resonance, 2015, 46 : 349 - 355