Location of Partial Discharge Source Model Based on Transformer Single-winding

被引:1
|
作者
Song XiaoHui [1 ]
Feng Xia [2 ]
Guo ZhiZhong [1 ]
Di JunFeng [3 ]
机构
[1] Harbin Inst Technol, Inst Elect Engn & Automat, Harbin 150001, Peoples R China
[2] Shanghai Univ Elect Power, Shanghai 200090, Peoples R China
[3] Shanghai XJ Elect Co Ltd, Shanghai 200122, Peoples R China
关键词
transformer model; partial discharge; position factor;
D O I
10.4028/www.scientific.net/AMM.628.171
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a new method to locate partial discharge source of transformer single-winding with the transformer single-winding model and Matlab software simulation. This transformer single-winding model is composed of 300m long wire, which is equivalent to the parameter model composed of only capacitors and inductors through the frequency characteristic analysis of transformer winding. In the process of simulation, the bushing and neutral point current of transformer winding are measured when partial discharge occurs in different position. Then we can get position factor related to the current mean and variance measured through calculation, analysis and deduction. Accordingly the position of partial discharge can be found by corresponding relation. This simulation indicates that this method is effective and practical.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 50 条
  • [21] Transformer partial discharge location technology based on gradient oil temperature
    Yu, Ruidong
    Zhang, Zhousheng
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [22] Simulation of partial discharge propagation and location in Abetti winding based on structural data
    Naderi, Mohammad S.
    Vakilian, M.
    Blackburn, T. R.
    Phung, B. T.
    Nam, Hio
    IPEC: 2005 INTERNATIONAL POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2005, : 206 - 210
  • [23] Single-winding regulating mode and harmonic current optimization of controllable reactor of transformer type
    Liu, Yibin
    Tian, Mingxing
    Yin, Jianning
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (07): : 74 - 82
  • [24] Characteristics of Partial Discharge during its Evolution in Transformer Winding
    Zheng, Zhong
    Yang, Yuan
    Li, Chengrong
    Liu, Shaoyu
    Ma, Jixian
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [25] Partial Discharge Detection and Localization inside the Winding of Power Transformer
    Rotby, Sally N.
    El-Hag, Ayman H.
    Salama, M. M. A.
    Bartnikas, R.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 84 - 87
  • [26] Partial discharge detection in transformer winding using FRA analysis
    Aissaoui, Nassima
    Houassine, Hamza
    Kabache, Nadir
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (08): : 52 - 56
  • [27] A narrowband high frequency distributed power transformer model for partial discharge location
    Mitchell, S. D.
    Welsh, J. S.
    Middleton, R. H.
    Phung, B. T.
    2007 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING, VOLS 1-2, 2007, : 545 - +
  • [28] Location of partial discharge in transformer by energy ratio method
    School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
    不详
    Gaodianya Jishu, 2006, 1 (38-39+53):
  • [29] Partial discharge location of transformer based on robust weighted total least square
    Xiao S.
    Wang Q.
    Zhou N.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (08): : 203 - 209
  • [30] Partial Discharge Signal Propagation Characteristics inside the Winding of Oil-immersed Power Transformer - Using the Three-Winding Transformer Model in Air
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 2024 - 2031