Effect of Pressure on Skin-Electrode Impedance in Wearable Biomedical Measurement Devices

被引:65
|
作者
Taji, Bahareh [1 ]
Chan, Adrian D. C. [2 ]
Shirmohammadi, Shervin [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON K1N 6N5, Canada
[2] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON, Canada
关键词
Biopotential electrodes; biosignal; Cole-Cole impedance model; impedance; pressure; signal quality; skin electrode; ELECTRICAL-PROPERTIES; MOTION ARTIFACTS; VITAL SIGNS; DRY; INTERFACE; ECG; ELECTROCARDIOGRAM; INTERFERENCE; MODEL;
D O I
10.1109/TIM.2018.2806950
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the effect of applied pressure on the skin-electrode impedance. Applied pressure, which affects the skin-electrode impedance, can fluctuate in many acquisition setups, particularly in wearable devices. The skin-electrode impedance, in turn, impacts the quality of the recorded signal in biomedical monitoring devices. Methods: Three types of electrodes were examined: Ag/AgCI electrodes, conductive textile electrodes, and dry electrodes with surface microfeatures (Orbital Research Inc.). Impedance measurements were conducted as pressure was repeatedly applied (P = 4 kPa) and removed (P = 0 kPa) over several trials. A Cole- Cole impedance model was utilized to model the skin-electrode interface. Significance and Results: Results demonstrated large decreases in the skin-electrode impedance of dry electrodes (conductive textile and orbital electrodes), especially with the initial application of the pressure. Model parameters also proved to be highly dependent on the level of pressure in dry electrodes but less dependent and more stable in wet electrodes. Decreases in skin-electrode impedance associated with applied pressure were thought to be caused by an increased effective electrode contact area. Changes in skin-electrode impedance were irreversible, lasting even after the applied pressure was released. Differences skin-electrode impedance associated with changes in applied pressure, decreased as the number of trials increased. Conclusion: Applied pressure has larger effect on dry electrodes than wet electrodes. Wearable devices that employ dry electrodes may have poorer biomedical signal quality when initially donned; however, the advantage of wet electrodes with their lower sensitivity to applied pressure is diminished in long-term monitoring applications.
引用
收藏
页码:1900 / 1912
页数:13
相关论文
共 50 条
  • [1] EFFECT OF SKIN PUNCTURE ON SKIN-ELECTRODE IMPEDANCE
    SMITH, DC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (04) : P483 - P483
  • [2] Measurement of skin-electrode impedance for a 12-lead electrocardiogram
    Zepeda-Carapia, I
    Márquez-Espinoza, A
    Alvarado-Serrano, C
    [J]. 2005 2nd International Conference on Electrical & Electronics Engineering (ICEEE), 2005, : 193 - 195
  • [3] Ergonomic skin-electrode impedance testing
    Shaffer, F
    Banks, L
    Lipps, A
    Franken, F
    Steinman, S
    [J]. APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2002, 27 (04) : 314 - 314
  • [4] SKIN-ELECTRODE IMPEDANCE PROBLEMS IN ELECTROCARDIOGRAPHY
    BERSON, AS
    PIPBERGER, HV
    [J]. AMERICAN HEART JOURNAL, 1968, 76 (04) : 514 - +
  • [5] Online Skin-Electrode Contact Quality Monitoring in Wearable Devices: An EEG Application
    Casadei, Valentina
    Ferrero, Roberto
    [J]. 2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [6] SKIN-ELECTRODE IMPEDANCE AND ITS EFFECT ON RECORDING CARDIAC POTENTIALS
    SPACH, MS
    BARR, RC
    HAVSTAD, JW
    LONG, EC
    [J]. CIRCULATION, 1966, 34 (04) : 649 - &
  • [7] SKIN-ELECTRODE IMPEDANCE AND ITS EFFECT ON RECORDING CARDIAC POTENTIALS
    SPACH, MS
    BARR, RC
    HAVSTAD, JW
    LONG, EC
    [J]. JOURNAL OF PEDIATRICS, 1966, 69 (5P2): : 963 - +
  • [8] Time based measurement of the impedance of the skin-electrode interface for dry electrode ECG recording
    Dozio, Roberta
    Baba, Adeshina
    Assambo, Cedric
    Burke, Martin J.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 5001 - 5004
  • [9] Characteristics of Skin-Electrode Impedance for a Novel Screw Electrode
    Jia, Wenyan
    Wu, Jiamin
    Gao, Di
    Sun, Mingui
    Sclabassi, Robert J.
    [J]. 2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [10] Electrochemical Characteristics Based on Skin-Electrode Contact Pressure for Dry Biomedical Electrodes and the Application to Wearable ECG Signal Acquisition
    Song, Jinzhong
    Zhou, Tianshu
    Liang, Zhonggang
    Liu, Ruoxi
    Guo, Jianping
    Yu, Xinming
    Cao, Zhongping
    Yu, Chuang
    Liu, Qingjun
    Li, Jingsong
    [J]. JOURNAL OF SENSORS, 2021, 2021