Time based measurement of the impedance of the skin-electrode interface for dry electrode ECG recording

被引:16
|
作者
Dozio, Roberta [1 ]
Baba, Adeshina [1 ]
Assambo, Cedric [1 ]
Burke, Martin J. [1 ]
机构
[1] Trinity Coll Dublin, Dept Elect & Elect Engn, Coll Green, Dublin 2, Ireland
关键词
D O I
10.1109/IEMBS.2007.4353463
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper reports the measurement of the properties of dry or pasteless conductive electrodes to be used for long-term recording of the human electrocardiogram (ECG). Knowledge of these properties is essential for the correct design of the input stage of associated recording amplifiers. Measurements were made on three commercially available conductive carbon based electrodes at pressures of 5mmHg and 20mmHg, located on the lower abdomen of the body on three subjects having different skin types. Parameter values were fitted to a two-time-constant based model of the electrode using data measured over a period of 10s. Values of resistance, ranging from 40k Omega to 1590k Omega and of capacitance ranging from 0.05 mu F to 38 mu F were obtained for the components, while the values of the time-constants varied from 0.07s to 3.9s.
引用
收藏
页码:5001 / 5004
页数:4
相关论文
共 50 条
  • [1] The Skin-Electrode Interface Impedance and the Transient Performance of ECG Recording Amplifiers
    Maji, Soumyajyoti
    Burke, Martin J.
    [J]. 2018 IEEE SENSORS, 2018, : 404 - 407
  • [2] Skin-electrode impedance measurement during ECG acquisition: method's validation
    Casal, Leonardo
    La Mura, Guillermo
    [J]. 20TH ARGENTINEAN BIOENGINEERING SOCIETY CONGRESS (XX ARGENTINE BIOENGINEERING CONGRESS AND IX CONFERENCE OF CLINICAL ENGINEERING), (SABI 2015), 2016, 705
  • [3] Time Evolution of the Skin-Electrode Interface Impedance under Different Skin Treatments
    Murphy, Brendan B.
    Scheid, Brittany H.
    Hendricks, Quincy
    Apollo, Nicholas, V
    Litt, Brian
    Vitale, Flavia
    [J]. SENSORS, 2021, 21 (15)
  • [4] ECG simulator with configurable skin-electrode impedance and artifacts emulation
    Almeida, Daniel
    Costa, Joao
    Lourenco, Andre
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (06)
  • [5] SKIN-ELECTRODE IMPEDANCE AND ITS EFFECT ON RECORDING CARDIAC POTENTIALS
    SPACH, MS
    BARR, RC
    HAVSTAD, JW
    LONG, EC
    [J]. CIRCULATION, 1966, 34 (04) : 649 - &
  • [6] SKIN-ELECTRODE IMPEDANCE AND ITS EFFECT ON RECORDING CARDIAC POTENTIALS
    SPACH, MS
    BARR, RC
    HAVSTAD, JW
    LONG, EC
    [J]. JOURNAL OF PEDIATRICS, 1966, 69 (5P2): : 963 - +
  • [7] Amplifier Input Impedance in Dry Electrode ECG Recording
    Assambo, Cedric
    Burke, Martin J.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1774 - 1777
  • [8] EFFECT OF SKIN PUNCTURE ON SKIN-ELECTRODE IMPEDANCE
    SMITH, DC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (04) : P483 - P483
  • [9] Characteristics of Skin-Electrode Impedance for a Novel Screw Electrode
    Jia, Wenyan
    Wu, Jiamin
    Gao, Di
    Sun, Mingui
    Sclabassi, Robert J.
    [J]. 2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [10] Ergonomic skin-electrode impedance testing
    Shaffer, F
    Banks, L
    Lipps, A
    Franken, F
    Steinman, S
    [J]. APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2002, 27 (04) : 314 - 314