Dynamic Supply Voltage Control for PA Output Power Correction Under Variable Loading Scenarios

被引:14
|
作者
Goncalves, Cristiano F. [1 ,2 ]
Barradas, Filipe M. [1 ,2 ]
Nunes, Luis C. [1 ,2 ]
Cabral, Pedro M. [1 ,2 ]
Pedro, Jose Carlos [1 ,2 ]
机构
[1] Inst Telecomunicacoes, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Campus Univ Santiago, P-3810193 Aveiro, Portugal
关键词
Meters; Voltage measurement; Loading; Power amplifiers; Impedance; Gallium nitride; Power generation; Load insensitivity; power amplifiers (PAs); < italic xmlns:ali="http; www; niso; org; schemas; ali; 1; 0; xmlns:mml="http; w3; 1998; Math; MathML" xmlns:xlink="http; 1999; xlink" xmlns:xsi="http; 2001; XMLSchema-instance"> V <; italic > DD modulation; IMPEDANCE; EFFICIENCY;
D O I
10.1109/TMTT.2020.3037963
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents an automatic system that is able to dynamically restore the output power capability of a power amplifier (PA) under variable loading scenarios. This is accomplished by dynamically adapting the supply voltage, VDD, of the PA according to the developed theoretical model. To dynamically vary VDD, a GaN dc-dc converter, based on the commercial EPC 9067 Demo Board, was used. The load is measured using an impedance meter, which is based on the slotted line principle and was specifically designed for low insertion loss. This impedance meter also generates a load-dependent pulsewidth modulated signal that controls the dc-dc converter switching, regulating VDD. The prototype was designed for 3.55 GHz and tested with CW and modulated signal excitations, being able to compensate the output power degradation under variable loading conditions inside a 2.1 voltage standing wave ratio circle. For a constant gain compression level, the average efficiency degradation over the tested range of impedances is less than 5%, and the average power improvement is 0.7 dB. The worst case measured output power of the PA is compensated from 37.0 to 39.9 dBm, which corresponds to a 2.9 dB improvement. Using a modulated signal excitation, the peak envelope power, which is compressed by almost 3 dB without VDD compensation, is restored, and the average output power is improved by 0.6 dB. The system can track the load and adjust VDD with a worst case step-up delay of 25 ms.
引用
收藏
页码:745 / 755
页数:11
相关论文
共 50 条
  • [31] Digital Voltage/Current Control of a High Voltage Output LCC Resonant Converter Based Power Supply for Capacitor Charging
    Ditmanson, Chester
    Gueldner, Henry
    Gleisberg, Frank
    Rentzsch, Martin
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 1210 - +
  • [32] Operating Region and Control for Power Converters Connected to a Variable Frequency and Amplitude Voltage Grid Supply
    Rohten, Jaime
    Espinoza, Jose
    Silva, Jose
    Munoz, Javier
    Sbarbaro, Daniel
    Baier, Carlos
    Espinosa, Eduardo
    2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2015, : 1094 - 1099
  • [33] Optimization Control Voltage Harmonics of PMSM Variable Frequency Power Supply Based on Boost Transform
    Tan J.
    Jing Y.
    Guo H.
    Yu Z.
    Li Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (21): : 4475 - 4482
  • [34] Ultra-Wide Output Voltage Range DC Power Supply with Multiple Power Modules Series/Parallel Variable Structure and Automatic Voltage/Current Sharing
    Li, Mengxi
    Wu, Hongfei
    Qu, Chengzhi
    Ji, Yuhui
    Lu, Yangjun
    Xing, Yan
    Sun, Kai
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 5935 - 5940
  • [35] Design of One-Cycle Control Power Factor Correction IC with Unipolar Supply Voltage
    Chang, Kai-Chi
    Chen, Kai-Hui
    Liang, Tsorng-Juu
    Liu, Bin-Da
    ISCAS: 2009 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-5, 2009, : 3078 - 3081
  • [36] DC Bus Voltage Influence and Stabilization Technology Under Servo Loading for Aerospace Combined Power Supply
    Qiu, Cheng
    Wang, Dexin
    Huang, Jing
    Tan, Qifan
    Li, Hangyu
    IEEE ACCESS, 2022, 10 : 78135 - 78147
  • [37] A single-chip variable supply voltage power amplifier
    Rippke, IA
    Duster, JS
    Kornegay, KT
    2005 IEEE RADIO FREQUENCY INTEGRATED CIRCUITS (RFIC) SYMPOSIUM, DIGEST OF PAPERS, 2005, : 255 - 258
  • [38] High-Voltage Isolated Multiple Output Auxiliary Power Supply with Output Voltage Self-Regulation
    Ai, Yu
    Shi, Yunming
    Chen, Shaoyong
    Zhang, Zehui
    Zhao, Shuai
    Liu, Jianqiang
    ENERGIES, 2022, 15 (06)
  • [39] A control method of inverter used for distributed power supply under voltage sag condition
    Hatano, Nobuhiko
    Taniguchi, Yuji
    Kouchi, Katsuhiko
    IEEJ Transactions on Industry Applications, 2008, 128 (01) : 71 - 82
  • [40] A Control Method for Inverter Used for Distributed Power Supply under Voltage Sag Condition
    Hatano, Nobuhiko
    Taniguchi, Yuji
    Kouchi, Katsuhiko
    ELECTRICAL ENGINEERING IN JAPAN, 2009, 169 (01) : 28 - 40