Dynamic Supply Voltage Control for PA Output Power Correction Under Variable Loading Scenarios

被引:14
|
作者
Goncalves, Cristiano F. [1 ,2 ]
Barradas, Filipe M. [1 ,2 ]
Nunes, Luis C. [1 ,2 ]
Cabral, Pedro M. [1 ,2 ]
Pedro, Jose Carlos [1 ,2 ]
机构
[1] Inst Telecomunicacoes, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Campus Univ Santiago, P-3810193 Aveiro, Portugal
关键词
Meters; Voltage measurement; Loading; Power amplifiers; Impedance; Gallium nitride; Power generation; Load insensitivity; power amplifiers (PAs); < italic xmlns:ali="http; www; niso; org; schemas; ali; 1; 0; xmlns:mml="http; w3; 1998; Math; MathML" xmlns:xlink="http; 1999; xlink" xmlns:xsi="http; 2001; XMLSchema-instance"> V <; italic > DD modulation; IMPEDANCE; EFFICIENCY;
D O I
10.1109/TMTT.2020.3037963
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents an automatic system that is able to dynamically restore the output power capability of a power amplifier (PA) under variable loading scenarios. This is accomplished by dynamically adapting the supply voltage, VDD, of the PA according to the developed theoretical model. To dynamically vary VDD, a GaN dc-dc converter, based on the commercial EPC 9067 Demo Board, was used. The load is measured using an impedance meter, which is based on the slotted line principle and was specifically designed for low insertion loss. This impedance meter also generates a load-dependent pulsewidth modulated signal that controls the dc-dc converter switching, regulating VDD. The prototype was designed for 3.55 GHz and tested with CW and modulated signal excitations, being able to compensate the output power degradation under variable loading conditions inside a 2.1 voltage standing wave ratio circle. For a constant gain compression level, the average efficiency degradation over the tested range of impedances is less than 5%, and the average power improvement is 0.7 dB. The worst case measured output power of the PA is compensated from 37.0 to 39.9 dBm, which corresponds to a 2.9 dB improvement. Using a modulated signal excitation, the peak envelope power, which is compressed by almost 3 dB without VDD compensation, is restored, and the average output power is improved by 0.6 dB. The system can track the load and adjust VDD with a worst case step-up delay of 25 ms.
引用
收藏
页码:745 / 755
页数:11
相关论文
共 50 条
  • [1] Optimal Supply Voltage for PA Output Power Correction under Load Varying Scenarios
    Goncalves, Cristiano F.
    Barradas, Filipe M.
    Nunes, Luis C.
    Cabral, Pedro M.
    Pedro, Jose C.
    PROCEEDINGS OF THE 2020 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2020, : 107 - 110
  • [2] Design of Variable Output Voltage Power Supply for Power Amplifier of Underwater Acoustic Sensor
    Choi, Seung-Soo
    Shim, Jae-Hyeok
    Kim, Jin-Yung
    Kim, In-Dong
    Nho, Eui-Cheol
    Moon, Won-Kyu
    Kim, Won-Ho
    2014 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2014, : 391 - 396
  • [3] Control Strategy of Power Factor Correction Converter for Fast Dynamic Response and Low Output Voltage Ripple
    Ren X.
    Bai L.
    Hui Q.
    Wu Y.
    Li K.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (14): : 2936 - 2945
  • [4] Variable output, soft-switching DC/DC converter for VLSI dynamic voltage scaling power supply applications
    Trescases, O
    Ng, WT
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 4149 - 4155
  • [5] A REGULATED POWER SUPPLY FOR IMAGE CONVERTERS WITH OUTPUT-VOLTAGE CONTROL
    KOROBKIN, VV
    MALYAVKI.LP
    SHCHELEV, MY
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (03): : 657 - &
  • [6] A VARIABLE VOLTAGE STABILIZED POWER SUPPLY
    SHARP, A
    WIRELESS WORLD, 1967, 73 (08): : 382 - &
  • [7] Establishing a Low and Variable Voltage Power Supply System with Digital Control
    Al-Daraje, Assim Hameed Yousif
    2019 16TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2019, : 242 - 245
  • [8] ESTIMATION OF RF PA NONLINEARITIES AFTER CROSS-CORRELATING POWER SUPPLY CURRENT AND OUTPUT VOLTAGE
    Veiga, Ricardo
    Mota, Pedro
    da Silva, Jose Machado
    2009 IEEE 15TH INTERNATIONAL MIXED-SIGNALS, SENSORS, AND SYSTEMS TEST WORKSHOPS, 2009, : 42 - 45
  • [9] Low power multiple output DC supply - Part II: crossover voltage control in multiple output DC supply
    Zajec, Peter
    Voncina, Danijel
    Nastran, Janez
    Petkovsek, Marko
    2006 12TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2006, : 969 - +
  • [10] Beat frequency oscillations in the output voltage of high voltage DC power supplies under pulsed loading
    Vishwanathan, N
    Ramanarayanan, V
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 654 - 658