Application of a newly developed hydrogen peroxide vapor phase sensor to HPV sterilizer

被引:0
|
作者
Taizo, I
Sinichi, A
Kawamura, K
机构
[1] Taiyo Toyo Sanso Co Ltd, Kawaguchi, Saitama, Japan
[2] Kinki Univ, Dept Pharmaceut Sci, Higashiosaka, Osaka 577, Japan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new type of concentration sensor for hydrogen peroxide vapor has been developed by making use of a semiconductor: Output from the vapor sensor has Deer? shown to have a good linear relationship with the logarithm of the concentration of hydrogen peroxide vapor. Concentration of hydrogen peroxide vapor introduced into the sterilization chamber could be kept constant by monitoring the concentration of the hydrogen peroxide vapor continuously and controlling the vapor supply, Temperature and humidity have also been kept constant. D-values for B, stearothermophilus ATCC 12980 at various concentrations of hydrogen peroxide vapor-have been determined by using the combination system of the hydrogen peroxide vapor sensor the hydrogen pei-oxide vapor supplier thermosensor and humidity sensor D-values at the temperature of 30 degrees C and the absolute humidity of 0.7 mg H2O/L thus obtained were 0.2 minutes at hydrogen peroxide concentration of 600 ppm and 1.2 minutes at 200 ppm at the temperature of 30 degrees C and 0.7 mg/L absolute humidity. D-values for B. stearothermophilus ATCC 12980 at various temperatures, humidity and levels of hydrogen peroxide concentration have also been determined. These fundamental data indicate that the sterilization by hydrogen peroxide vapor-cart be validated as precisely as steam sterilization by measuring and controlling the concentration of hydrogen peroxide vapor using a combination of the hydrogen peroxide concentration sensor and the vapor generator. Influence of temperature and humidity have also been studied. The hydrogen peroxide sensor has been calibrated and standardized by using the standard hydrogen peroxide vapor whose concentration has been determined by calculating partial pressure of hydrogen per-oxide over the water-hydrogen peroxide solution.
引用
下载
收藏
页码:13 / 18
页数:6
相关论文
共 50 条
  • [21] Self-powered hydrogen peroxide sensor and its application as a biosensor
    Ohnuki, Hitoshi
    Wako, Takuya
    Mecheri, Barbara
    Wu, Haiyun
    Tsuya, Daiju
    Endo, Hideaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2019, 58 (SB)
  • [22] CYTOTOXICITY OF MEDICAL MATERIALS STERILIZED WITH VAPOR-PHASE HYDROGEN-PEROXIDE
    IKARASHI, Y
    TSUCHIYA, T
    NAKAMURA, A
    BIOMATERIALS, 1995, 16 (03) : 177 - 183
  • [23] Inactivation of Murine Norovirus on Fruit and Vegetable Surfaces by Vapor Phase Hydrogen Peroxide
    Becker, Barbara
    Dabisch-Ruthe, Mareike
    Pfannebecker, Jens
    JOURNAL OF FOOD PROTECTION, 2020, 83 (01) : 45 - 51
  • [24] PYRAPAK - A NEWLY DEVELOPED VERTICAL CONTACT PACKING FOR GAS VAPOR LIQUID-PHASE CONTACTING
    KULBE, B
    KUBICK, W
    HOPPE, K
    KELLER, J
    CHEMISCHE TECHNIK, 1982, 34 (04): : 214 - 214
  • [25] Trace Detection of Hydrogen Peroxide Vapor Using a Carbon-Nanotube-Based Chemical Sensor
    Lu, Yijiang
    Meyyappan, M.
    Li, Jing
    SMALL, 2011, 7 (12) : 1714 - 1718
  • [26] The intrinsic redox reactions of polyamic acid derivatives and their application in hydrogen peroxide sensor
    Hua, Mu-Yi
    Chen, Hsiao-Chien
    Chuang, Cheng-Keng
    Tsai, Rung-Ywan
    Jeng, Jyh-Long
    Yang, Hung-Wei
    Chern, Yaw-Terng
    BIOMATERIALS, 2011, 32 (21) : 4885 - 4895
  • [27] Electrochemical production of Graphene Oxide and its application as a novel Hydrogen Peroxide sensor
    Kivrak, Hilal Demir
    Aktas, Nahit
    Caglar, Aykut
    INTERNATIONAL JOURNAL OF NANO DIMENSION, 2019, 10 (03) : 252 - 259
  • [28] VAPOR-PHASE HYDROGEN-PEROXIDE INHIBITS POSTHARVEST DECAY OF TABLE GRAPES
    FORNEY, CF
    RIJ, RE
    DENISARRUE, R
    SMILANICK, JL
    HORTSCIENCE, 1991, 26 (12) : 1512 - 1514
  • [29] Application of pyrite and chalcopyrite as sensor electrode for amperometric detection and measurement of hydrogen peroxide
    Wang, Y.
    Zhao, K. J.
    Tao, D. P.
    Zhai, F. G.
    Yang, H. B.
    Zhang, Z. Q.
    RSC ADVANCES, 2018, 8 (09): : 5013 - 5019
  • [30] Hydrogen peroxide sensor based on dawson-type molybdophosphate and its application
    Du, D
    Wang, SF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (10) : 1318 - 1318