Quality assurance of stem cell enumeration by flow cytometry

被引:0
|
作者
Chin-Yee, I
Anderson, L
Keeney, M
Sutherland, DR
机构
[1] Univ Western Ontario, London Hth Sci Ctr, London, ON N6A 4G5, Canada
[2] Toronto Hosp, Toronto, ON M5T 2S8, Canada
[3] NE Ontario Reg Canc Ctr, Sudbury, ON, Canada
[4] Canadian Red Cross Blood Transfus Serv, Ottawa Ctr, Ottawa, ON, Canada
[5] Hop Maison Neuve Rosemont, Div Hematol, Montreal, PQ, Canada
[6] Hop St Sacrement, Quebec City, PQ, Canada
[7] Univ Alberta Hosp, Dept Lab Med, Edmonton, AB T6G 2B7, Canada
[8] Hosp Sick Children, Haematol Lab, Toronto, ON M5G 1X8, Canada
[9] Foothills Hosp, Calgary, AB T2N 2T9, Canada
[10] Hotel Dieu, Lab Cytometrie, Montreal, PQ, Canada
[11] Hamilton Gen Hosp, Dept Lab Med, Hamilton, New Zealand
[12] Hop Sacre Coeur, Serv Hematol Oncol, Montreal, PQ H4J 1C5, Canada
[13] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[14] Hop Gen Juif Sir Mortimer B Davis, Special Hematol Lab, Montreal, PQ, Canada
[15] British Columbia Childrens Hosp, Immunol Lab, Vancouver, BC V6H 3V4, Canada
[16] Princess Margaret Hosp, Toronto, ON M4X 1K9, Canada
[17] Victoria Gen Hosp, Div Hematol, Halifax, NS B3H 2Y9, Canada
来源
CYTOMETRY | 1997年 / 30卷 / 06期
关键词
quality assurance; CD34; hematopoietic stem cells; standardization;
D O I
10.1002/(SICI)1097-0320(19971215)30:6<296::AID-CYTO5>3.0.CO;2-E
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The enumeration of CD34+ cells by flow cytometry is commonly employed to assess progenitor/stem cell numbers in peripheral blood, cord blood, and apheresis products used for peripheral blood stem cell transplantation (PBSCT). Until recently, the enumeration of CD34+ cells has evolved in the absence of any procedural guidelines or quality assurance programs. We established a voluntary quality assurance for stem cell enumeration (QASE) program for Canadian laboratories involved in PBSCT. The goals of this study were 1) to survey current flow cytometric procedures for CD34 enumeration; 2) to evaluate inter-institutional reproducibility of currently employed assays; and 3) to evaluate the impact of adoption of a common method on inter-laboratory variability. Fourteen to nineteen laboratories participated in this program by enumerating CD34+ cells in shared cord blood samples. The survey showed a wide variation in flow cytometric methodology which in part contributed to the wide range in results obtained between different centres. Major differences in methodology included the number of events counted, use of isotype control and gating strategy. Participation in this program and adoption of a common methodology increased level of agreement for any given result although this trend did not reach statistical significance (P = 0.13). The results of this survey emphasize the need for a quality assurance program for stem cell enumeration by flow cytometry. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [31] Advancing Diagnostic Accuracy and Quality of Patient Care Through the Implementation of a Flow Cytometry Quality Assurance Program
    Wang, D.
    Ok, C.
    Jorgensen, J.
    Medeiros, L.
    Wang, W.
    Wang, S.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2024, 162 : S84 - S84
  • [32] PNH TESTING BY FLOW CYTOMETRY: A CANADIAN MULTI-CENTRE QUALITY ASSURANCE SURVEY
    Keeney, Michael
    Kimmel, David
    Brown, Wendy
    Chin-Yee, Ian
    Sutherland, Robert
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2010, 78B (06) : 396 - 396
  • [33] Quality assurance issues in DNA image cytometry
    Marchevsky, A
    Tolmachoff, T
    Lee, S
    CYTOMETRY, 1996, 26 (02): : 101 - 107
  • [34] Insights into the enumeration of mixtures of probiotic bacteria by flow cytometry
    Tracey, Harry
    Coates, Niall
    Hulme, Eleri
    John, Daniel
    Michael, Daryn Robert
    Plummer, Susan Frances
    BMC MICROBIOLOGY, 2023, 23 (01)
  • [35] Flow Cytometry Evolution of Microbiological Methods for Probiotics Enumeration
    Pane, Marco
    Allesina, Serena
    Amoruso, Angela
    Nicola, Stefania
    Deidda, Francesca
    Mogna, Luca
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2018, 52 : S41 - S45
  • [36] Insights into the enumeration of mixtures of probiotic bacteria by flow cytometry
    Harry Tracey
    Niall Coates
    Eleri Hulme
    Daniel John
    Daryn Robert Michael
    Susan Frances Plummer
    BMC Microbiology, 23
  • [37] Routine enumeration of leukocytes in plateletpheresis concentrates by flow cytometry
    Wittmann, G
    Hahn, U
    Endres, W
    Mempel, W
    TRANSFUSION, 1998, 38 (10) : 28S - 28S
  • [38] Enumeration of bone marrow plasmacytoid dendritic cells by multiparameter flow cytometry as a prognostic marker following allogeneic hematopoietic stem cell transplantation
    Su, Ruijun Jeanna
    Green, Ralph
    Chen, Mingyi
    BLOOD CELLS MOLECULES AND DISEASES, 2018, 69 : 107 - 112
  • [39] ENUMERATION OF ANTIGEN SITES ON CELLS BY FLOW-CYTOMETRY
    DAWSON, CD
    SCHEPPLER, JA
    NICHOLSON, JKA
    HOLMAN, RC
    PATHOBIOLOGY, 1991, 59 (02) : 57 - 61
  • [40] Quality assurance of hematopoietic stem cells by macrophages determines stem cell clonality
    Wattrus, Samuel J.
    Smith, Mackenzie L.
    Rodrigues, Cecilia Pessoa
    Hagedorn, Elliott J.
    Kim, Ji Wook
    Budnik, Bogdan
    Zon, Leonard I.
    SCIENCE, 2022, 377 (6613) : 1413 - +