Automated Mass Spectral Deconvolution and Identification System for GC-MS Screening for Drugs, Poisons, and Metabolites in Urine

被引:107
|
作者
Meyer, Markus R. [1 ]
Peters, Frank T. [1 ,2 ]
Maurer, Hans H. [1 ]
机构
[1] Univ Saarland, Dept Expt & Clin Toxicol, Inst Expt & Clin Pharmacol & Toxicol, D-66421 Homburg, Saar, Germany
[2] Univ Jena, Inst Forens Med, Jena, Germany
关键词
TOXICOLOGICAL ANALYSIS; FORENSIC TOXICOLOGY; LIQUID-CHROMATOGRAPHY; SPECTROMETRY; SAMPLES; TOOLS;
D O I
10.1373/clinchem.2009.135517
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: The challenge in systematic toxicological analysis using gas chromatography and/or liquid chromatography coupled to mass spectrometry is to identify compounds of interest from background noise. The large amount of spectral information collected in one full-scan MS run demands the use of automated evaluation of recorded data files. We evaluated the applicability of the freeware deconvolution software AMDIS (Automated Mass Spectral Deconvolution and Identification System) for GC-MS-based systematic toxicological analysis in urine for increasing the speed of evaluation and automating the daily routine workload. METHODS: We prepared a set of 111 urine samples for GC-MS analysis by acidic hydrolysis, liquid-liquid extraction, and acetylation. After analysis, the resulting data files were evaluated manually by an experienced toxicologist and automatically using AMDIS with deconvolution and identification settings previously optimized for this type of analysis. The results by manual and AMDIS evaluation were then compared. RESULTS: The deconvolution settings for the AMDIS evaluation were successfully optimized to obtain the highest possible number of components. Identification settings were evaluated and chosen for a compromise between most identified targets and general number of hits. With the use of these optimized settings, AMDIS-based data analysis was comparable or even superior to manual evaluation and reduced by half the overall analysis time. CONCLUSIONS: AMDIS proved to be a reliable and powerful tool for daily routine and emergency toxicology. Nevertheless, AMDIS can identify only targets present in the user-defined target library and may therefore not indicate unknown compounds that might be relevant in clinical and forensic toxicology. (C) 2009 American Association for Clinical Chemistry
引用
收藏
页码:575 / 584
页数:10
相关论文
共 50 条
  • [21] Comparison of HPLC and GC-MS for measurement of cocaine and metabolites in human urine
    Phillips, DL
    Tebbett, IR
    Bertholf, RL
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (05) : 305 - 308
  • [22] Simultaneous determination of methadone, heroin, cocaine and their metabolites in urine by GC-MS
    Alvarez, I.
    Palos, F.
    Bermejo, A. M.
    Fernandez, P.
    Tabernero, M. J.
    ANALYTICAL LETTERS, 2006, 39 (07) : 1393 - 1399
  • [23] A sensitive GC-MS procedure for the analysis of flunitrazepam and its metabolites in urine
    ElSohly, MA
    Feng, SX
    Salamone, SJ
    Wu, R
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (05) : 335 - 340
  • [25] Development of a GC-MS/MS strategy to determine 15 mycotoxins and metabolites in human urine
    Rodriguez-Carrasco, Yelko
    Carlos Molto, Juan
    Manes, Jordi
    Berrada, Houda
    TALANTA, 2014, 128 : 125 - 131
  • [26] Identification of metabolites of malathion in plant, water and soil by GC-MS
    Kaur, I
    Mathur, RP
    Tandon, SN
    Dureja, P
    BIOMEDICAL CHROMATOGRAPHY, 1997, 11 (06) : 352 - 355
  • [27] Separation and identification of norcantharidin metabolites in vivo by GC-MS method
    Wei, Chunmin
    Teng, Yanni
    Wang, Benjie
    Zhang, Xiumei
    Yuan, Guiyan
    Liu, Xiaoyan
    Li, Rong
    Guo, Ruichen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (20): : 1741 - 1747
  • [28] Identification of tamoxifen and metabolites in human male urine by GC/MS
    Mihailescu, R
    Aboul-Enein, HY
    Efstatide, MD
    BIOMEDICAL CHROMATOGRAPHY, 2000, 14 (03) : 180 - 183
  • [29] Qualitative screening for drugs of abuse in hair using GC-MS
    Paterson, S
    McLachlan-Troup, N
    Cordero, R
    Dohnal, M
    Carman, S
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (03) : 203 - 208
  • [30] A New Automated Method for the Analysis of Aromatic Amines in Human Urine by GC-MS/MS
    Mazumder, Shrila
    Ahamed, Rayaj A.
    McGahee, Ernest
    Wang, Lanqing
    Seyler, Tiffany H.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (01) : 25 - 35