Performance evaluation of continuous PM2.5 mass concentration monitors

被引:13
|
作者
Lee, JH
Hopke, PK
Holsen, TM
Lee, DW
Jaques, PA
Sioutas, C
Ambs, JL
机构
[1] Clarkson Univ, Dept Chem Engn, Potsdam, NY 13699 USA
[2] Clarkson Univ, Dept Civil & Environm Engn, Potsdam, NY 13699 USA
[3] Univ Calif Los Angeles, Ctr Environm & Occupat Hlth, Los Angeles, CA 90024 USA
[4] Univ So Calif, Dept Civil & Environm Engn, Los Angeles, CA USA
[5] Rupprecht & Patashnick Co Inc, E Greenbush, NY USA
关键词
D O I
10.1016/j.jaerosci.2004.07.006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
PM2.5 mass concentrations were measured on a short time interval basis using the continuous ambient mass monitor (CAMM) and real-time ambient mass sampler (RAMS) along with a differential tapered element oscillating microbalance (TEOM) in Rubidoux CA, and intercomparisons were made among these samplers to evaluate their measurement performance Of PM2.5 mass. Nephelometers were used as an additional sampler to assist in the between-sampler comparisons. Based on the correlation with particulate nitrate concentrations and particulate mass, the differential TEOM showed better measurement of semivolatile species in PM2.5 than either the CAMM or the RAMS. The RAMS typically measured more mass than the CAMM. The results suggest that the differential TEOM was better reflecting the PM2.5 mass concentrations, with less impact from the loss of semivolatile, components. Particulate ammonium nitrate losses estimated from the paired Harvard-EPA annular denuder system and a commercial federal reference method (FRM) sampler were equivalent to the PM2.5 mass difference between the paired differential TEOM and FRM samplers. It suggests that volatilization of semivolatile ammonium nitrate was substantial at Rubidoux, and thus. the differential TEOM performed better in measurement of the actual PM2.5 mass concentrations, including semivolatile and non-volatile PM, with less loss of semivolatile materials from the filter. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 109
页数:15
相关论文
共 50 条
  • [21] Study on the Uncertainty of the Calibration Device of PM2.5 Mass Concentration Monitor
    Zou, Junchen
    Fan, Wei
    Shi, Enjie
    Lu, Xindong
    Zhou, Xingang
    Li, Guoqiang
    Fan, Zhenxing
    Liu, Huiyuan
    Xu, Xueqiong
    Liu, Xiuxiu
    Wang, Lin
    Liu, Wensi
    Zhang, Ye
    2ND INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 450
  • [23] Profiling the PM2.5 mass concentration vertical distribution in the boundary layer
    Tao, Zongming
    Wang, Zhenzhu
    Yang, Shijun
    Shan, Huihui
    Ma, Xiaomin
    Zhang, Hui
    Zhao, Sugui
    Liu, Dong
    Xie, Chenbo
    Wang, Yingjian
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (03) : 1369 - 1376
  • [24] Assessment of the regional source contributions to PM2.5 mass concentration in Beijing
    Han Xiao
    Zhang Mei-Gen
    ATMOSPHERIC AND OCEANIC SCIENCE LETTERS, 2018, 11 (02) : 143 - 149
  • [25] The quantitative relationship between visibility and mass concentration of PM2.5 in Beijing
    Wang, J. -L.
    Zhang, Y. -H.
    Shao, M.
    Liu, X. -L.
    AIR POLLUTION XIV, 2006, 86 : 595 - +
  • [26] Assessment of the regional source contributions to PM2.5 mass concentration in Beijing
    HAN Xiao
    ZHANG Mei-Gen
    Atmospheric and Oceanic Science Letters, 2018, 11 (02) : 143 - 149
  • [27] Evaluation of new low-cost particle monitors for PM2.5 concentrations measurements
    Zikova, Nadezda
    Hopke, Philip K.
    Ferro, Andrea R.
    JOURNAL OF AEROSOL SCIENCE, 2017, 105 : 24 - 34
  • [29] PM2.5还是PM2.5
    邓春琴
    编辑学报, 2014, 26 (03) : 240 - 240
  • [30] Performance evaluation of photographic measurement in the machine-learning prediction of ground PM2.5 concentration
    Feng, Limin
    Yang, Ting
    Wang, Zifa
    ATMOSPHERIC ENVIRONMENT, 2021, 262