Performance evaluation of continuous PM2.5 mass concentration monitors

被引:13
|
作者
Lee, JH
Hopke, PK
Holsen, TM
Lee, DW
Jaques, PA
Sioutas, C
Ambs, JL
机构
[1] Clarkson Univ, Dept Chem Engn, Potsdam, NY 13699 USA
[2] Clarkson Univ, Dept Civil & Environm Engn, Potsdam, NY 13699 USA
[3] Univ Calif Los Angeles, Ctr Environm & Occupat Hlth, Los Angeles, CA 90024 USA
[4] Univ So Calif, Dept Civil & Environm Engn, Los Angeles, CA USA
[5] Rupprecht & Patashnick Co Inc, E Greenbush, NY USA
关键词
D O I
10.1016/j.jaerosci.2004.07.006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
PM2.5 mass concentrations were measured on a short time interval basis using the continuous ambient mass monitor (CAMM) and real-time ambient mass sampler (RAMS) along with a differential tapered element oscillating microbalance (TEOM) in Rubidoux CA, and intercomparisons were made among these samplers to evaluate their measurement performance Of PM2.5 mass. Nephelometers were used as an additional sampler to assist in the between-sampler comparisons. Based on the correlation with particulate nitrate concentrations and particulate mass, the differential TEOM showed better measurement of semivolatile species in PM2.5 than either the CAMM or the RAMS. The RAMS typically measured more mass than the CAMM. The results suggest that the differential TEOM was better reflecting the PM2.5 mass concentrations, with less impact from the loss of semivolatile, components. Particulate ammonium nitrate losses estimated from the paired Harvard-EPA annular denuder system and a commercial federal reference method (FRM) sampler were equivalent to the PM2.5 mass difference between the paired differential TEOM and FRM samplers. It suggests that volatilization of semivolatile ammonium nitrate was substantial at Rubidoux, and thus. the differential TEOM performed better in measurement of the actual PM2.5 mass concentrations, including semivolatile and non-volatile PM, with less loss of semivolatile materials from the filter. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 109
页数:15
相关论文
共 50 条
  • [1] Performance evaluation of continuous PM2.5 mass concentration monitors
    Lee, Jong Hoon
    Hopke, Philip K.
    Holsen, Thomas M.
    Lee, Doh-Won
    A. Jaques, Peter
    Sioutas, Constantinos
    Ambs, Jeffrey L.
    Journal of Aerosol Science, 2005, 36 (01): : 95 - 109
  • [2] Evaluation of continuous and filter-based methods for measuring PM2.5 mass concentration
    Lee, JH
    Hopke, PK
    Holsen, TM
    Polissar, AV
    AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (04) : 290 - 303
  • [3] Development and evaluation of a continuous ambient PM2.5 mass monitor
    Babich, P
    Wang, PY
    Allen, G
    Sioutas, C
    Koutrakis, P
    AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (04) : 309 - 324
  • [4] Analysis on mass concentration of PM2.5 in Kunshan
    Yu Liangmin
    Yu Lei
    Chen Feng
    Gu Haidong
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON CIVIL, ARCHITECTURAL AND HYDRAULIC ENGINEERING (ICCAHE 2016), 2016, 95 : 236 - 241
  • [5] On the concentration differences between PM2.5 FEM monitors and FRM samplers
    Le, Thi-Cuc
    Shukla, Krishna Kumar
    Chen, Yu-Ting
    Chang, Shun-Chin
    Lin, Tsai-Yin
    Li, Ziyi
    Pui, David Y. H.
    Tsai, Chuen-Jinn
    ATMOSPHERIC ENVIRONMENT, 2020, 222
  • [6] China monitors PM2.5 nationwide
    Huang, Ganlin
    FRONTIERS IN ECOLOGY AND THE ENVIRONMENT, 2013, 11 (06) : 287 - 287
  • [7] Comparison of PM2.5 and PM10 monitors
    RON WILLIAMS
    JACK SUGGS
    CHARLES RODES
    PHIL LAWLESS
    ROY ZWEIDINGER
    RICHARD KWOK
    JOHN CREASON
    LINDA SHELDON
    Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 497 - 505
  • [8] Comparison of PM2.5 and PM10 monitors
    Williams, R
    Suggs, J
    Rodes, C
    Lawless, P
    Zweidinger, R
    Kwok, R
    Creason, J
    Sheldon, L
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (05): : 497 - 505
  • [9] STUDY ON THE PERFORMANCE OF THE SPOT CALIBRATION DEVICE OF PM2.5 MASS CONCENTRATION MONITOR
    Zou, Junchen
    Li, Jianpeng
    Yan, Jiwei
    Yang, Zhanqi
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (03): : 2773 - 2780
  • [10] Field evaluation of the differential TEOM monitor for continuous PM2.5 mass concentrations
    Jaques, PA
    Ambs, JL
    Grant, WL
    Sioutas, C
    AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 : 49 - 59