Sizing of the buffer tank in chilled water distribution air-conditioning systems

被引:14
|
作者
Cervera-Vazquez, Javier [1 ]
Montagud-Montalva, Carla [1 ]
Miguel Corberan, Jose [1 ]
机构
[1] Univ Politecn Valencia, Inst Ingn Energet, Camino Vera S-N, E-46022 Valencia, Spain
关键词
HEAT-PUMP;
D O I
10.1080/23744731.2016.1131569
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article presents a sizing study of the buffer tank in chilled water air-conditioning systems. In order to find out the adequate sizing criteria for buffer tanks in these kind of installations, a review of different manufacturers' guidelines was carried out and it was concluded that there are three main operation parameters affected by the volume of the tank: the ON cycle time, the OFF cycle time, and the number of starts per hour of the chiller compressor. In order to better understand the influence of each parameter, a theoretical analysis was carried out where the impact of the building thermal load in different design criteria was also studied. After a thorough analysis of all the studied criteria, it was concluded that the minimum ON cycle time which is necessary to ensure that the oil returns to the compressor is the most critical criterion. Finally, a design guideline is proposed by the authors in order to determine the minimum volume of the buffer tank, mainly depending on the capacity of the chiller and the temperature deadband of the thermostat control.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 50 条
  • [1] Distributed Pumping Chilled Water Hydronic System for Air-conditioning Systems
    Lam, Sam K. H.
    Tham, Chris
    Saseedharan, Sunil
    Chun, Liong Yin
    Wang, Adrian
    [J]. LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 88 - 93
  • [2] A New Air-conditioning System with Chilled Water Storage
    Lin, Hu
    Li, Xinhong
    Cheng, Pengsheng
    Xu, Bugong
    [J]. PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2964 - +
  • [3] PLANT-ENERGY CONTROL OF AIR-CONDITIONING AND CHILLED WATER-SYSTEMS
    KANWISHER, N
    [J]. PLASTICS ENGINEERING, 1984, 40 (03) : 38 - 38
  • [4] The Optimal Control Strategy for Chilled Water System in Central Air-conditioning Systems
    Li, Ao
    Wang, Fulin
    Li, Rui
    Zhu, Binruo
    Huang, Dan
    Chen, Gang
    [J]. IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 8150 - 8155
  • [5] ECOMOMIC ASSESSMENT OF CHILLED WATER THERMAL STORAGE AND CONVENTIONAL AIR-CONDITIONING SYSTEMS
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    [J]. TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 : 1485 - 1495
  • [6] Research on energy consumption of variable frequency chilled water pumps in air-conditioning systems
    Wang, HD
    [J]. CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 607 - 610
  • [7] AIR-CONDITIONING - SYSTEM SIZING
    ABRAMS, DW
    [J]. SOLAR AGE, 1983, 8 (01): : 56 - 56
  • [8] Comparison of energy performance and economics of chilled water thermal storage and conventional air-conditioning systems
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 237 - 250
  • [9] Design of a chilled-water storage unit for solar air-conditioning
    Serag-Eldin, M. A.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 385 - 405
  • [10] Optimum sizing of air-conditioning chillers
    Maheshwari, GP
    Hussain, HJ
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 441 - 445