Computer simulation of the thermal regime of double-loop channel induction furnaces

被引:9
|
作者
Ghojel, JI [1 ]
Ibrahim, RN [1 ]
机构
[1] Monash Univ, Dept Engn Mech, Melbourne, Vic 3143, Australia
关键词
computer; simulation; channel; induction; furnace;
D O I
10.1016/j.jmatprotec.2004.04.123
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Double-channel induction furnaces are used extensively in many processing industries due, mainly, to their relatively low operating costs. However, thermal stresses in the refractory lining caused by high temperatures during the loading cycle can cause erosion of the lining and premature inductor failure. Prevention of premature failure by close monitoring of the thermal regime of the inductor is very important to operators and relatively simple and reliable tools need to be developed to this end. The present work is related to the development of such a tool using a thermal modelling software and unidirectional axial channel flow speeds of the melt that are estimated from analysis based on the first-law of thermodynamics. This analysis reduces the cost, complications and uncertainties associated with coupled multiple field analysis approach. The results of the analysis show reasonable correlation with reported flow data and a comprehensive set of scenarios can be devised on the basis of the developed approach to simulate start-up, transient operation and steady state operation of double-channel induction furnaces. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:386 / 391
页数:6
相关论文
共 34 条
  • [21] Simulation of D-band double-loop phase-locked system
    Chen, Mo
    Jiang, Yiping
    Xu, Jinping
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2008, 38 (03): : 371 - 375
  • [22] Design and simulation of a novel FOIMC-PD/P double-loop control structure for CSTRs and bioreactors
    Kumari, Shweta
    Aryan, Pulakraj
    Raja, G. Lloyds
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2021, 19 (12) : 1287 - 1303
  • [23] Computer simulation of double-winding linear induction motor
    Zhao, ZW
    Li, GY
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 5, 2005, : 351 - 355
  • [24] COMPUTER-SIMULATION OF SNOWMELT AND SOIL THERMAL REGIME AT BARROW, ALASKA
    OUTCALT, SI
    GOODWIN, C
    WELLER, G
    BROWN, J
    WATER RESOURCES RESEARCH, 1975, 11 (05) : 709 - 715
  • [25] The Development and Testing of a Double-Loop Resolution-Level Controller for a 3φ WM Inverter-Fed Induction Motor
    Saleh, S. A.
    Rahman, M. A.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2950 - +
  • [26] Value of information of time-lapse seismic data by simulation-regression: comparison with double-loop Monte Carlo
    Dutta, Geetartha
    Mukerji, Tapan
    Eidsvik, Jo
    COMPUTATIONAL GEOSCIENCES, 2019, 23 (05) : 1049 - 1064
  • [27] Value of information of time-lapse seismic data by simulation-regression: comparison with double-loop Monte Carlo
    Geetartha Dutta
    Tapan Mukerji
    Jo Eidsvik
    Computational Geosciences, 2019, 23 : 1049 - 1064
  • [28] Numerical simulation of the frequency dependence of the degree of efficiency in induction channel furnaces in the low-frequency range
    Numerische simulation der frequenzabhängigkeit des wirkungsgrades bei lnduktionsrinnenäfen im niederfrequenzbereich
    1600, Vulkan Verlag GmbH
  • [29] Computer simulation of PET high-speed thermal channel spinning
    Tang, Z.
    Huang, N.
    Yu, X.
    Huo, P.
    Xu, X.
    Chemical Fibers International, 2001, 51 (06): : 437 - 441
  • [30] Computer simulation of polyester high-speed thermal channel spinning
    Huang, NX
    Yu, HH
    Tang, ZL
    Hou, PM
    Xu, XC
    MACROMOLECULAR MATERIALS AND ENGINEERING, 2002, 287 (05) : 330 - 338