Real-time dobutamine stress myocardial contrast echocardiography for detecting coronary artery disease: Correlating abnormal wall motion and disturbed perfusion

被引:0
|
作者
Chiou, KR
Huang, WC
Lin, SL
Hsieh, PL
Liu, CP
Tsay, DG
Chiang, HT
机构
[1] Kaohsiung Vet Gen Hosp, Div Cardiol, Dept Internal Med, Kaohsiung 813, Taiwan
[2] Kaohsiung Vet Gen Hosp, Dept Nucl Med, Kaohsiung 813, Taiwan
[3] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
关键词
contrast media; coronary artery disease; dobutamine echocardiography;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Real-time myocardial contrast echocardiography (MCE) makes possible the simultaneous visualization of changes in perfusion imaging and wall motion. OBJECTIVES: To assess the accuracy of real,time MCE for detecting the presence and extent of coronary artery disease (CAD), and to evaluate the correlation between wall motion and myocardial perfusion by visual examination. METHODS: A total of 140 consecutive patients without resting wall motion abnormalities were screened to undergo dobutamine stress MCE with power modulation and coronary angiography. Significant coronary disease was defined by the quantification of over 50% stenosis in a major epicardial vessel. The visual identification of wall motion and myocardial perfusion abnormalities was determined by blind review. RESULTS: Eight patients were excluded due to suboptimal images (feasibility 94.3%). Myocardial contrast enhancement analysis and wall motion analysis were similar in terms of sensitivity (81.2% versus 83.5%, respectively) and specificity (76.5% versus 80.9%, respectively) in detecting the presence of CAD. Myocardial contrast enhancement analysis tended to have a greater sensitivity than wall motion analysis in detecting the ischemic extent over multiple vascular territories among patients with multiple-vessel disease (sensitivity 83.8% versus 71.4% [P=0.09], and abnormal segment length 54.7 +/- 21.1% versus 48.9 +/- 24.7% [P=0.03] for myocardial contrast enhancement and wall motion analysis, respectively). There was good concordance between the presence of myocardial ischemia and wall motion abnormality for the segment-by-segment analysis (89.7% agreement, kappa = 0.745). The correlation of the wall motion score and perfusion score at peak stress was also good (r=0.793, P=0.015). CONCLUSIONS: Dobutamine stress MCE with power modulation is similar in sensitivity and specificity to wall motion analysis for detecting the presence of CAD. However, it provides greater sensitivity in evaluating the extent of ischemia in patients with multiple-vessel disease.
引用
收藏
页码:1237 / 1243
页数:7
相关论文
共 50 条
  • [21] Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs
    Xing Yan-qiu
    Hou Bo-wen
    Zhang Yun
    Liu Xiang-qun
    Gao Hai-qing
    CHINESE MEDICAL JOURNAL, 2009, 122 (17) : 2002 - 2007
  • [22] Quantitative evaluation of myocardial perfusion in coronary heart disease by myocardial contrast and dobutamine stress echocardiography
    Guo, Liping
    Zhang, Yuanxiang
    Wen, Jia
    Chen, Jing
    JOURNAL OF CLINICAL ULTRASOUND, 2025, 53 (02) : 234 - 241
  • [23] Quantitative evaluation of regional myocardial perfusion during dipyridamole stress by real-time myocardial contrast echocardiography in patients with and without coronary artery disease
    Scuteri, L
    De Filippo, P
    Revera, M
    Previtali, M
    Lanzarini, L
    Canosi, U
    Ferlini, M
    Klersy, C
    EUROPEAN HEART JOURNAL, 2003, 24 : 104 - 104
  • [24] Evaluation of restenosis and extent of coronary artery disease in patients with previous percutaneous coronary interventions by dobutamine stress real-time myocardial contrast perfusion imaging
    Elhendy, A.
    Tsutsui, J. M.
    O'Leary, E. L.
    Xie, F.
    Majeed, F.
    Porter, T. R.
    HEART, 2006, 92 (10) : 1480 - 1483
  • [25] Value of Low-Dose Dobutamine Stress Real-Time Myocardial Contrast Echocardiography in the Diagnosis of Coronary Heart Disease
    Jiang, Li
    Yao, Hong
    Sun, Jiang-Hong
    Shen, Jing-Xia
    Tian, Ye
    Liang, Zhao-Guang
    AMERICAN JOURNAL OF THERAPEUTICS, 2017, 24 (03) : E270 - E277
  • [26] Real-time dobutamine stress myocardial perfusion echocardiography predicts outcome in the elderly
    Tsutsui, Jeane M.
    Xie, Feng
    Cloutier, David
    Kalvaitis, Saul
    Elhendy, Abdou
    Porter, Thomas R.
    EUROPEAN HEART JOURNAL, 2008, 29 (03) : 377 - 385
  • [27] Contrast enhanced real-time 3D dobutamine stress echocardiography in assessment of patients with coronary artery disease
    Ahmad, M
    PROCEEDINGS OF THE 4TH WORLD CONGRESS OF ECHOCARDIOGRAPHY AND VASCULAR ULTRASOUND, 2000, : 9 - 13
  • [28] Adenosine stress real time myocardial contrast echocardiography in the detection of coronary artery disease
    Hong, GR
    Chung, N
    Rim, SJ
    Kang, SM
    Kim, HJ
    Ahn, JA
    Choi, D
    Jang, Y
    Cho, SY
    Kim, SS
    CIRCULATION, 2002, 106 (19) : 675 - 675
  • [29] Detection of Subendocardial Ischemia in the Left Anterior Descending Coronary Artery Territory With Real-Time Myocardial Contrast Echocardiography During Dobutamine Stress Echocardiography
    Xie, Feng
    Dodla, Saritha
    O'Leary, Edward
    Porter, Thomas R.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (03) : 271 - 278
  • [30] Enhanced sensitivity of dobutamine stress echocardiography for the diagnosis of coronary artery disease using real time myocardial contrast echocardiography at an intermediate stage of the test
    Elhendy, A
    McGrain, AC
    O'Leary, EL
    Xie, F
    Porter, TR
    CIRCULATION, 2003, 108 (17) : 339 - 339