Rapid screening and characterization of drug metabolites using a new quadrupole-linear ion trap mass spectrometer

被引:103
|
作者
Hopfgartner, G
Husser, C
Zell, M
机构
[1] Univ Geneva, Lab Pharmaceut Analyt Chem, CH-1211 Geneva 4, Switzerland
[2] F Hoffmann La Roche & Co Ltd, Div Pharmaceut, Pharma Res, Non Clin Drug Safety, CH-4070 Basel, Switzerland
来源
JOURNAL OF MASS SPECTROMETRY | 2003年 / 38卷 / 02期
关键词
linear ion trap; metabolism; ionspray; liquid chromatography/mass spectrometry; collision-induced dissociation;
D O I
10.1002/jms.420
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of a new hybrid RF/DC quadrupole-linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high-sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information-dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in-space configuration, quadrupole-like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS' capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:138 / 150
页数:13
相关论文
共 50 条
  • [21] A practical strategy for the characterization of coumarins in Radix Glehniae by liquid chromatography coupled with triple quadrupole-linear ion trap mass spectrometry
    Yang, Wei
    Ye, Min
    Liu, Man
    Kong, Dezhi
    Shi, Rui
    Shi, Xiaowei
    Zhang, Kerong
    Wang, Qiao
    Lantong, Zhang
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (27) : 4587 - 4600
  • [22] An integrated approach for profiling oxidative metabolites and glutathione adducts using liquid chromatography coupled with ultraviolet detection and triple quadrupole-linear ion trap mass spectrometry
    Chen, Guiying
    Cheng, Zhongzhe
    Zhang, Kerong
    Jiang, Hongliang
    Zhu, Mingshe
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 129 : 482 - 491
  • [23] Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in baby food
    Rubert, Josep
    James, Kevin J.
    Manes, Jordi
    Soler, Carla
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1223 : 84 - 92
  • [24] Evaluation of multiple reaction monitoring cubed performed by a quadrupole-linear ion trap mass spectrometer for quantitative determination of 6-sulfatoxymelatonin in urine
    Lopukhov, Leonid, V
    Balandina, Anna, V
    Nigmatullina, Lilia S.
    Mullakhmetova, Adelya F.
    Synbulatova, Gulnaz E.
    Laikov, Alexander, V
    Lopukhov, Victor L.
    Grigoryeva, Tatiana, V
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1190
  • [25] Mass spectrometry of stanozolol and its analogues using electrospray ionization and collision-induced dissociation with quadrupole-linear ion trap and linear ion trap-orbitrap hybrid mass analyzers
    Thevis, M
    Makarov, AA
    Horning, S
    Schänzer, W
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (22) : 3369 - 3378
  • [26] Hybrid triple quadrupole-linear ion trap mass spectrometry in fragmentation mechanism studies: application to structure elucidation of buspirone and one of its metabolites
    Zhang, MY
    Pace, N
    Kerns, EH
    Kleintop, T
    Kagan, N
    Sakuma, T
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08): : 1017 - 1029
  • [27] An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system
    Cha, BC
    Blades, M
    Douglas, DJ
    ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5647 - 5654
  • [29] Microfabricated quadrupole ion trap for mass spectrometer applications
    Pau, S
    Pai, CS
    Low, YL
    Moxom, J
    Reilly, PTA
    Whitten, WB
    Ramsey, JM
    PHYSICAL REVIEW LETTERS, 2006, 96 (12)
  • [30] Identification and Quantification of Chlorpyrifos Metabolites in Urine Samples by Ultra Performance Liquid Chromatography-Triple Quadrupole-Linear Ion Trap Mass Spectrometry
    Song Ning-Hui
    Xu Huai-Zhou
    Ji Gui-Xiang
    Zhang Sheng-Hu
    Zhang Qin
    Guo Min
    Shi Li-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (05) : 796 - 802