Application research of master-slave cranio-maxillofacial surgical robot based on force feedback

被引:8
|
作者
Xu, Cheng [1 ]
Wang, Yang [2 ]
Zhou, Chaozheng [1 ]
Zhang, Zhenfeng [1 ]
Xie, Le [1 ,3 ]
Andersson, Kjell [2 ]
Feng, Lei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Forming Technol & Equipment, Minhang Campus,800 Dongchuan RD, Shanghai 200040, Peoples R China
[2] KTH, Dept Machine Design, Brinellvagen 83, S-11428 Stockholm, Sweden
[3] Shanghai Jiao Tong Univ, Inst Med Robot, Minhang Campus,800 Dongchuan RD, Shanghai 200040, Peoples R China
基金
中国国家自然科学基金;
关键词
Cranio-maxillofacial surgery; master-slave robot; force feedback; robot assisted surgery; MANIPULATORS; SURGERY; SYSTEM; DISTURBANCE; OSTEOTOMY;
D O I
10.1177/0954411921997568
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The complex anatomical structure, limited field of vision, and easily damaged nerves, blood vessels, and other anatomical structures are the main challenges of a cranio-maxillofacial (CMF) plastic surgical robot. Bearing these characteristics and challenges in mind, this paper presents the design of a master-slave surgical robot system with a force feedback function to improve the accuracy and safety of CMF surgery. Methods: A master-slave CMF surgical robot system based on force feedback is built with the master tactile robot and compact slave robot developed in the laboratory. Model-based master robot gravity compensation and force feedback mechanism is used for the surgical robot. Control strategies based on position increment control and ratio control are adopted. Aiming at the typical mandibular osteotomy in CMF surgery, a scheme suitable for robot-assisted mandibular osteotomy is proposed. The accuracy and force feedback function of the robot system under direct control and master-slave motion modes are verified by experiments. Results: The drilling experiment of the mandible model in direct control mode shows that the average entrance point error is 1.37 +/- 0.30 mm, the average exit point error is 1.30 +/- 0.25 mm, and the average posture error is 2.27 degrees +/- 0.69 degrees. The trajectory tracking and in vitro experiment in the master-slave motion mode show that the average position following error is 0.68 mm, and the maximum force following error is 0.586 N, achieving a good tracking and force feedback function. Conclusion: The experimental results show that the designed master-slave CMF robot can assist the surgeon in completing accurate mandibular osteotomy surgery. Through force feedback mechanism, it can improve the interaction between the surgeon and the robot, and complete tactile trajectory movements.
引用
收藏
页码:583 / 596
页数:14
相关论文
共 50 条
  • [21] Retinal Surgical Field Realignment Based on Master-Slave Dual-Arm Surgical Robot
    Zhang, He
    Pang, Linjun
    Bai, Ming
    Yang, Jiahui
    Zhao, Jie
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2024, 21 (03) : 4743 - 4752
  • [22] MASTER-SLAVE CONTROL METHOD WITH FORCE FEEDBACK FOR GRASPING SOFT OBJECTS USING A TELEOPERATION CONSTRUCTION ROBOT
    Huang, Lingtao
    Kawamura, Takuya
    Yamada, Hironao
    INTERNATIONAL JOURNAL OF FLUID POWER, 2012, 13 (02) : 41 - 49
  • [23] Teleoperation Master-slave Robot Based on Binocular Vision
    Mai, Xiaoming
    Xuan Yuwen
    Wang, Yang
    Chen, Long
    2018 11TH INTERNATIONAL WORKSHOP ON HUMAN FRIENDLY ROBOTICS (HFR), 2018, : 72 - 77
  • [24] Control Strategy of Master-Slave Manipulator Based on Force Feedback for Decommissioning of Nuclear Facilities
    Wang, Jin
    Li, Haoyuan
    Meng, Fansheng
    Ma, Rui
    Lai, Quanbin
    Li, Jianwu
    Duan, Xingguang
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2022, 2022
  • [25] Research and Implementation of Master-Slave Control for Interventional Robot System
    Xie Qingcheng
    Chen Guo
    Han Shipeng
    2017 2ND ASIA-PACIFIC CONFERENCE ON INTELLIGENT ROBOT SYSTEMS (ACIRS), 2017, : 234 - 239
  • [26] Control Strategy of Master-Slave Manipulator Based on Force Feedback for Decommissioning of Nuclear Facilities
    Wang, Jin
    Li, Haoyuan
    Meng, Fansheng
    Ma, Rui
    Lai, Quanbin
    Li, Jianwu
    Duan, Xingguang
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2022, 2022
  • [27] An Improved Master-Slave Interventional Surgery Robotic System with Force Feedback
    Guo, Shuxiang
    Li, Guangxuan
    Gao, Baofeng
    Wang, Yuan
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 415 - 419
  • [28] Characteristic Evaluation of a Master-Slave Interventional Surgical Robot Control system
    Guo, Shuxiang
    Yang, Cheng
    Bao, Xianqiang
    Xiao, Nan
    Shen, Rui
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 421 - 425
  • [29] Research on Live Working Robot Based on Weak Rigid Master-slave Control Algorithm
    Liu, Jizhi
    Ji, Hongwei
    Zhao, Yabo
    Zhang, Huadong
    Zhao, Jinlong
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 1344 - 1348
  • [30] Target Object Color-Based Force Feedback Compensation Control in Master-Slave Systems
    Fudaba, Yudai
    Tsusaka, Yuko
    Ozawa, Jun
    2014 23RD IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION (IEEE RO-MAN), 2014, : 454 - 459