Impedimetric label-free sensor for specific bacteria endotoxin detection by surface charge registration

被引:29
|
作者
Brosel-Oliu, Sergi [1 ]
Galyamin, Dmitry [1 ]
Abramova, Natalia [1 ,2 ]
Munoz-Pascual, Francesc-Xavier [1 ]
Bratov, Andrey [1 ]
机构
[1] CSIC, Ctr Nacl Microelect IMB CNM, Inst Microelect Barcelona, BioMEMS Grp,Esfera UAB CEI, Campus UAB, Barcelona 08193, Spain
[2] ITMO Univ, Lab Artificial Sensors Syst, Kronverskiy Pr 49, St Petersburg 197101, Russia
关键词
Impedimetric sensor; Surface charge; Interdigitated electrode array; Bacterial endotoxin; Concanavalin A; QUARTZ-CRYSTAL MICROBALANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; INTERDIGITATED ELECTRODE ARRAY; CONCANAVALIN-A; LECTIN; BIOSENSOR; CARBOHYDRATE; ADSORPTION; PROTEIN; SAMPLES;
D O I
10.1016/j.electacta.2017.05.060
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An impedimetric sensor based on a three dimensional electrode array modified with concanavalin A (Con A) was used for label-free detection of bacterial endotoxin: lipopolysaccharide (LPS) from Escherichia coli. The transducer permits the detection of the surface charge changes due to interaction of immobilized Con A biorecognition element and LPS of E. coli in test solution. The deposition of Con A on the surface was carried out using the layer-by-layer method with polyethyleneimine (PEI) polycation as an initial layer. The sensor surface characterization by means of electrochemical impedance spectroscopy technique allowed registering variations in superficial resistance provoked by surface charge changes and is demonstrated as an effective method to monitor sensor parameters at each modification step as well as to follow Con A - LPS reaction. In order to prevent non-specific adsorption of LPS on PEI covered surface different blocking strategies were tested to achieve the specific response between Con A and LPS. Results obtained in this work clearly show that blocking with bovine serum albumin (BSA) is not sufficient to prevent non-specific interactions of PEI and to ensure the selective biorecognition of LPS by Con A. To achieve more efficient PEI blocking a new method was proposed based on consecutive deposition of Con A-glycogen-Con A layers. Sensors modified with PEI-(Con A-Gly)(2)-Con A multilayers are shown to be highly sensitive, selective and reproducible. Presented biosensor is able to detect bacterial LPS in a very short detection time (20 min) with 2 mu g mL(-1) limit of detection, which is much lower than reported for other biosensors with Con A. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 50 条
  • [21] Microwave biosensors for label-free bacteria detection
    Piekarz, Ilona
    Sorocki, Jakub
    Gorska, Sabina
    Wincza, Krzysztof
    Gruszczynski, Slawomir
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 109 - 111
  • [22] Optical Methods for Label-Free Detection of Bacteria
    Wang, Pengcheng
    Sun, Hao
    Yang, Wei
    Fang, Yimin
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [23] Label-free biosensor for viruses and bacteria detection
    Aznakayev, Emir
    Aznakayeva, Diana
    NANO-, BIO-, INFO-TECH SENSORS, AND 3D SYSTEMS IV, 2020, 11378
  • [24] Development of an impedimetric sensor for the label-free detection of the amino acid sarcosine with molecularly imprinted polymer receptors
    Tin Phan Nguy
    Toan Van Phi
    Tram, Do T. N.
    Eersels, Kasper
    Wagner, Patrick
    Lien, Truong T. N.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 : 461 - 470
  • [25] A label-free impedimetric aptasensor for the detection of Bacillus anthracis spore simulant
    Mazzaracchio, Vincenzo
    Neagu, Daniela
    Porchetta, Alessandro
    Marcoccio, Eleonora
    Pomponi, Alice
    Faggioni, Giovanni
    D'Amore, Nino
    Notargiacomo, Andrea
    Pea, MarialLilia
    Moscone, Danila
    Palleschi, Giuseppe
    Lista, Florigio
    Arduini, Fabiana
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 640 - 646
  • [26] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [27] Nanocrystalline diamond impedimetric aptasensor for the label-free detection of human IgE
    Tran, Dinh T.
    Vermeeren, Veronique
    Grieten, Lars
    Wenmackers, Sylvia
    Wagner, Patrick
    Pollet, Jeroen
    Janssen, Kris P. P.
    Michiels, Luc
    Lammertyn, Jeroen
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (06): : 2987 - 2993
  • [28] Development of a label-free impedimetric immunosensor for the detection of respiratory syncytial virus
    Stefanne e Silva, Tallita
    Oliveira e Freitas, Guilherme Ramos
    Ferreira, Lucas Franco
    Franco, Diego Leoni
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (11) : 4015 - 4027
  • [29] A label-free electrical impedimetric biosensor for the specific detection of Alzheimer's amyloid-beta oligomers
    Rushworth, Jo V.
    Ahmed, Asif
    Griffiths, Heledd H.
    Pollock, Niall M.
    Hooper, Nigel M.
    Millner, Paul A.
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 83 - 90
  • [30] Impedimetric Microfluidic Sensor-in-a-Tube for Label-Free Immune Cell Analysis
    Egunov, Aleksandr, I
    Dou, Zehua
    Karnaushenko, Dmitriy D.
    Hebenstreit, Franziska
    Kretschmann, Nicole
    Akgun, Katja
    Ziemssen, Tjalf
    Karnaushenko, Daniil
    Medina-Sanchez, Mariana
    Schmidt, Oliver G.
    SMALL, 2021, 17 (05)