Electrochemical determination of chemical oxygen demand on functionalized pseudo-graphite electrode

被引:9
|
作者
Kabir, Humayun [1 ]
Zhu, Haoyu [1 ]
Lopez, Ricardo [1 ]
Nicholas, Nolan W. [2 ]
Mcllroy, David N. [3 ]
Echeverria, Elena [3 ]
May, Jeremy [1 ]
Cheng, I. Francis [1 ]
机构
[1] Univ Idaho, Dept Chem, 875 Perimeter Dr,MS 2343, Moscow, ID 83844 USA
[2] ABB Inc USCRC, 131 Phoenix Crossing, Bloomfield, CT 06002 USA
[3] Oklahoma State Univ, Dept Phys, 145 Phys Sci Bldg, Stillwater, OK 74028 USA
关键词
Pseudo-graphite; Carbon electrode; Chemical oxygen demand (COD); FLOW-INJECTION ANALYSIS; DIAMOND-LIKE CARBON; AMPEROMETRIC DETERMINATION; GRAPHENE OXIDE; SENSOR; COD; SPECTROSCOPY;
D O I
10.1016/j.jelechem.2019.113448
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Graphite-like carbon electrodes produced from the University of Idaho thermolyzed asphalt reaction (GUITAR) were examined for anodic sensing of chemical oxygen demand (COD). For maximum sensitivity the surfaces were modified with quinone functionality (q-GUITAR). Analysis by FT-IR indicated C-OH and C=O groups on the surface which was verified by and X-ray photoelectron spectroscopies (XPS). The capacitance as measured by cyclic voltammetry (CV) of q-GUITAR is 170 times greater in 1.0 M H2SO4 than the pristine material indicating a more hydrophilic surface. This enhances the anodic oxidations of the COD surrogates consisting of glucose, potassium hydrogen phthalate (KHP), lactic acid, and sodium dodecyl benzenesulfonate (SDBS). At a constant potential of 1.6 V vs. Ag/AgCl q-GUITAR anodes have the largest linear range of 0 to 10,000 ppm (as glucose) reported in literature. The limit of detection (40 ppm) and sensitivity are competitive with other electrode systems.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A new FTO/TiO2/PbO2 electrode for eco-friendly electrochemical determination of chemical oxygen demand
    Lei Wang
    Yuehan Zhang
    Xiaoxuan Sun
    Yunhui Li
    Junfeng Zhai
    Shaojun Dong
    Nano Research, 2023, 16 : 11042 - 11047
  • [32] A sensitive and environmentally friendly method for determination of chemical oxygen demand using NiCu alloy electrode
    Zhou, Yusun
    Jing, Tao
    Hao, Qiaolin
    Zhou, Yikai
    Mei, Surong
    ELECTROCHIMICA ACTA, 2012, 74 : 165 - 170
  • [33] AN AUTOMATED SYSTEM FOR DETERMINATION OF CHEMICAL OXYGEN DEMAND
    HEY, AE
    GREEN, A
    HARKNESS, N
    WATER RESEARCH, 1969, 3 (12) : 873 - &
  • [34] Dichromate method for the determination of chemical oxygen demand
    Dedkov, YM
    Elizarova, OV
    Kel'ina, SY
    JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (08) : 777 - 781
  • [35] Determination of Chemical Oxygen Demand for Saline Wastewater
    Ma, Xiangjuan
    Gao, Yang
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [36] RAPID METHOD FOR DETERMINATION OF CHEMICAL OXYGEN DEMAND
    STENGER, VA
    VANHALL, CE
    ANALYTICAL CHEMISTRY, 1967, 39 (02) : 206 - +
  • [37] Optimization of the determination of chemical oxygen demand in wastewaters
    Viana da Silva, Alexandra M. E.
    Bettencourt da Silva, Ricardo J. N.
    Camoes, M. Filomena G. F. C.
    ANALYTICA CHIMICA ACTA, 2011, 699 (02) : 161 - 169
  • [38] Dichromate method for the determination of chemical oxygen demand
    Yu. M. Dedkov
    O. V. Elizarova
    S. Yu. Kel’ina
    Journal of Analytical Chemistry, 2000, 55 : 777 - 781
  • [39] Pencil graphite electrode as an electrochemical sensor for the voltammetric determination of chlorpromazine
    Purushothama, H. T.
    Nayaka, Y. Arthoba
    Vinay, M. M.
    Manjunatha, P.
    Yathisha, R. O.
    Basavarajappa, K. V.
    JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2018, 3 (02): : 161 - 166
  • [40] Sensitive Electrochemical Determination of Trifluralin at a Disposable Pencil Graphite Electrode
    Gege, Umit
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2021, 33 (06) : 1547 - 1556