Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction

被引:6
|
作者
Sheng, Hui [1 ]
Wang, Xueling [1 ]
Jiang, Meiping [2 ]
Zhang, Zhongsheng [3 ]
机构
[1] Yantaishan Hosp, Dept Radiol, Yantai 264000, Peoples R China
[2] Yuhuangding Hosp, Dept Ultrason, Yantai 264000, Peoples R China
[3] Yuhuangding Hosp, Dept Radiol, Yantai 264000, Peoples R China
关键词
STROKE; MODEL; DWI;
D O I
10.1155/2022/6270700
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The prefiltered image was imported into the local higher-order singular value decomposition (HOSVD) denoising algorithm (GL-HOSVD)-optimized diffusion-weighted imaging (DWI) image, which was compared with the deviation correction nonlocal mean (NL mean) and low-level edge algorithm (LR + edge). Regarding the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), sensitivity, specificity, accuracy, and consistency, the application effect of the GL-HOSVD algorithm in DWI was investigated, and its adoption effect in the examination of ischemic penumbra (IP) of early acute cerebral infarction (ACI) patients was evaluated. A total of 210 patients with ACI were selected as the research subjects, who were randomly rolled into two groups. Those who were checked by conventional DWI were set as the control group, and those who used DWI based on the GL-HOSVD denoising algorithm were set as the observation group, with 105 people in each. Positron emission tomography (PET) test results were set as the gold standard to evaluate the application value of the two examination methods. It was found that under different noise levels, the peak signal-to-noise ratio (PSNR) of the GL-HOSVD algorithm and the root mean square error (RMSE) of the FA parameter were better than those of the nonlocal means (NL-means) of deviation correction and low-rank edge algorithm (LR + edge). The sensitivity, specificity, accuracy, and consistency (8.76%, 81.25%, 87.62%, and 0.52) of the observation group were higher than those of the control group (57.78%, 53.33%, 57.14%, and 0.35) (P < 0.05). Moreover, the apparent diffusion coefficient (ADC) of the DWI images of the observation group was basically consistent with that of the PET images, while the control group had a poor display effect and low definition. In summary, under different noise levels, the GL-HOSVD algorithm had a good denoising effect and greatly reduced fringe artifacts. DWI after denoising had high sensitivity, specificity, accuracy, and consistency in the detection of IP, which was worthy of clinical application and promotion.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Medial Medullary Infarction Identified by Diffusion-Weighted Magnetic Resonance Imaging
    Shono, Yuji
    Koga, Masatoshi
    Toyoda, Kazunori
    Matsuoka, Hideki
    Yokota, Chiaki
    Uehara, Toshiyuki
    Yamamoto, Haruko
    Minematsu, Kazuo
    CEREBROVASCULAR DISEASES, 2010, 30 (05) : 519 - 524
  • [32] Vertebral body infarction revealed by diffusion-weighted magnetic resonance imaging
    Kobayashi, Makoto
    Kanai, Tetsuya
    JOURNAL OF NEUROLOGY, 2013, 260 (04) : 1160 - 1162
  • [33] Vertebral body infarction revealed by diffusion-weighted magnetic resonance imaging
    Makoto Kobayashi
    Tetsuya Kanai
    Journal of Neurology, 2013, 260 : 1160 - 1162
  • [34] Spinal cord infarction demonstrated by diffusion-weighted magnetic resonance imaging
    Shinoyama, M
    Takahashi, T
    Shimizu, H
    Tominaga, T
    Suzuki, M
    JOURNAL OF CLINICAL NEUROSCIENCE, 2005, 12 (04) : 466 - 468
  • [35] Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Cerebral Venous Thrombosis : A Meta-Analysis
    Lv, Bin
    Jing, Feng
    Tian, Cheng-lin
    Liu, Jian-chao
    Wang, Jun
    Cao, Xiang-yu
    Liu, Xin-feng
    Yu, Sheng-yuan
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2021, 64 (03) : 418 - 426
  • [36] Diffusion-weighted magnetic resonance imaging of cerebral white matter development
    Prayer, D
    Prayer, L
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (03) : 235 - 243
  • [37] Diffusion-weighted magnetic resonance imaging in a case of cerebral venous thrombosis
    Corvol, JC
    Oppenheim, C
    Manaï, R
    Logak, M
    Dormont, D
    Samson, Y
    Marsault, C
    Rancurel, G
    STROKE, 1998, 29 (12) : 2649 - 2652
  • [38] Cerebral fat embolism: Diffusion-weighted magnetic resonance imaging findings
    Ryu, CW
    Lee, DH
    Kim, TK
    Kim, SJ
    Kim, HS
    Lee, JH
    Choi, CG
    Suh, DC
    ACTA RADIOLOGICA, 2005, 46 (05) : 528 - 533
  • [39] A machine learning-based method for estimating the number and orientations of major fascicles in diffusion-weighted magnetic resonance imaging
    Karimi, Davood
    Vasung, Lana
    Jaimes, Camilo
    Machado-Rivas, Fedel
    Khan, Shadab
    Warfield, Simon K.
    Gholipour, Ali
    MEDICAL IMAGE ANALYSIS, 2021, 72
  • [40] Magnetic resonance imaging diffusion-weighted imaging for diagnosis of a gastric hepatoid adenocarcinoma
    Velut, Guillaume
    Mary, Florence
    Aflalo, Vanessa
    Aparicio, Thomas
    DIGESTIVE AND LIVER DISEASE, 2015, 47 (02) : 174 - 174