Vessel/perfusion density in two optical coherence tomography angiography protocols. Interchangeable?

被引:0
|
作者
Monares-Zepeda, Gerardo [1 ]
Montano, Margarita [2 ]
Bonilla, Luisa A. [2 ]
Chew-Bonilla, Alan [2 ]
Lima-Gomez, Virgilio [3 ]
机构
[1] Clin Microcirugia Ocular Avanzada Dr Enrique Mona, Serv Retina, Toluca, Edo, Mexico
[2] Oftalmol, Toluca, Edo, Mexico
[3] Hosp Juarez Mexico, Serv Oftalmol, Ciudad De Mexico, Mexico
来源
GACETA MEDICA DE MEXICO | 2021年 / 157卷 / 02期
关键词
Optical coherence tomography angiography; Vessel density; Perfusion density; Macula; Scanning protocol; REPRODUCIBILITY; REPEATABILITY; AREA;
D O I
10.24875/GMM.20000471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Different optical coherence tomography angiography (OCTA) scanning protocols evaluate the macula. Objective: To compare the determination coefficients (R2) between vessel and perfusion densities of two OCTA scanning protocols, to learn whether their metrics could be interchanged. Method: Non-experimental, comparative, prospective, observational, cross-sectional study, between two OCTA scanning protocols (Angioplex, Zeiss) in healthy subjects. We found the R2 between central, inner, and full densities (3 x 3 mm protocol), and between central, inner, outer and full densities (6 x 6 mm protocol), both for vessel and perfusion densities. Results: 78 eyes, median age 23 years. There were high R2 between inner and full densities in the 3 x 3 mm protocol (0.96), between outer and full densities in the 6 x 6 mm protocol (0.96) and between central vessel and perfusion densities (>= 0.96); R2 between central vessel and perfusion densities of different protocols (<= 0.71). Conclusions: Vessel and perfusion densities have high determination coefficients within a scanning protocol, but not between protocols, because each preferentially measures different macular areas. The metrics of different protocols should not be interchanged for follow-up.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 50 条
  • [31] Peripapillary Vessel Density Measured by Optical Coherence Tomography Angiography in Idiopathic Intracranial Hypertension
    Bilen, Feyza Tuntas
    Atilla, Huban
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2019, 39 (03) : 319 - 323
  • [32] Repeatability and reproducibility of vessel density measurements on optical coherence tomography angiography in diabetic retinopathy
    Emily S. Levine
    Malvika Arya
    Juhi Chaudhari
    Eugenia Custo Greig
    A. Yasin Alibhai
    Caroline R. Baumal
    Andre J. Witkin
    Jay S. Duker
    Nadia K. Waheed
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1687 - 1695
  • [33] Repeatability of vessel density measurements using optical coherence tomography angiography in retinal diseases
    Lee, Min-Woo
    Kim, Kyeung-Min
    Lim, Hyung-Bin
    Jo, Young-Joon
    Kim, Jung-Yeul
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (05) : 704 - 710
  • [34] The application of peripapillary vessel density in the diagnosis of primary glaucoma by optical coherence tomography angiography
    Ma, Feiyan
    Lv, Xi
    Liang, Shuang
    Liu, Xiaoli
    Duan, Jialiang
    Zhang, Bin
    Liu, Danyan
    MINERVA SURGERY, 2024, 79 (04): : 507 - 510
  • [35] Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes
    Yarmohammadi, Adeleh
    Zangwill, Linda M.
    Diniz-Filho, Alberto
    Suh, Min Hee
    Manalastas, Patricia Isabel
    Fatehee, Naeem
    Yousefi, Siamak
    Belghith, Akram
    Saunders, Luke J.
    Medeiros, Felipe A.
    Huang, David
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT451 - OCT459
  • [36] Vessel density analysis in patients with retinitis pigmentosa by means of optical coherence tomography angiography
    Parodi, Maurizio Battaglia
    Cicinelli, Maria Vittoria
    Rabiolo, Alessandro
    Pierro, Luisa
    Gagliardi, Marco
    Bolognesi, Gianluigi
    Bandello, Francesco
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 428 - 432
  • [37] Effect of caffeine on vessel density in healthy subjects assessed with optical coherence tomography angiography
    Jacobs, Mitchell
    Turski, Christopher
    Fowler, Nicholas
    Kupper, Victoria
    Acharya, Kishor
    Chadwell, John
    Dupont, Alec
    Demas, Nicholas
    Maldonado, Ramiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [38] Morphology and Vessel Density of the Macula in Preterm Children Using Optical Coherence Tomography Angiography
    Czeszyk, Agnieszka
    Hautz, Wojciech
    Jaworski, Maciej
    Bulsiewicz, Dorota
    Czech-Kowalska, Justyna
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [39] The investingation of optic disc vessel density by swept source optical coherence tomography angiography
    Kimura, Itaru
    Kanno, Junji
    Shoji, Takuhei
    Yoshikawa, Yuji
    Ozaki, Kimitake
    Ibuki, Hisashi
    Ishii, Hirokazu
    Akiyama, Tadashi
    Shinoda, Kei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [40] Gap in Capillary Perfusion on Optical Coherence Tomography Angiography
    Huang, Wenbin
    Sha, Xiangyin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (07) : 3044 - 3044