Postmortem analysis of consecutively retrieved asymmetric porous-coated tibial components

被引:27
|
作者
Bloebaum, RD [1 ]
Bachus, KN [1 ]
Jensen, JW [1 ]
Hofmann, AA [1 ]
机构
[1] VA Med Ctr, Bone & Joint Res Lab 151F, Salt Lake City, UT 84148 USA
来源
JOURNAL OF ARTHROPLASTY | 1997年 / 12卷 / 08期
关键词
backscattered electron; bone ingrowth; porous coating; tibia; total knee;
D O I
10.1016/S0883-5403(97)90162-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of this investigation was to conduct a postmortem analysis of 8 porous-coated asymmetric tibial components to measure the extent of radiolucencies and bone ingrowth. With the use of radiographic, electron microscope, and histologic analysis techniques, a quantitative postmortem study of 8 consecutively retrieved porous-coated tibial components was conducted. Time in situ averaged 47 +/- 36 months. The components were secured with 4 pegs and 2 screws. Autograft bone chips were applied to the resected tibia during implantation. Contact radiographs of an average of 8 3-mm sections from each implant revealed that 73% +/- 17% of the porous coating had no apparent radiolucencies present between the host bone and porous coating for the series. Backscattered electron imaging showed that the bone ingrowth averaged 6% +/- 2%. Histologic analysis was unable to demonstrate any adverse cellular response. The analysis suggested that this asymmetric implant design is stable and biocompatible and has potential for long-term clinical durability.
引用
收藏
页码:920 / 929
页数:10
相关论文
共 50 条
  • [41] Analysis of temporal wear patterns of porous-coated acetabular components: Distinguishing between true wear and so-called bedding-in
    Sychterz, CJ
    Engh, CA
    Yang, A
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (06): : 821 - 830
  • [42] Analysis of Migration of Press-Fit Porous-Coated Acetabular Components With Medial Lucencies Using Ein-Bild-Roentegen-Analyse
    Sadeghi, Cameron
    Gibson, Anthony G.
    Ries, Michael D.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1354 - 1357
  • [43] Finite element analysis of crestal bone loss around porous-coated dental implants
    Vaillancourt, H.
    Pilliar, R.M.
    McCammond, D.
    Journal of applied biomaterials, 6 (04): : 267 - 282
  • [44] POROUS COATED ANATOMIC TRICOMPARTMENTAL TIBIAL COMPONENTS - THE RELATIONSHIP BETWEEN PROSTHETIC POSITION AND MICROMOTION
    RYD, L
    LINDSTRAND, A
    STENSTROM, A
    SELVIK, G
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (251) : 189 - 197
  • [45] HYDROXYAPATITE-COATED FEMORAL STEMS - HISTOLOGICAL ANALYSIS OF COMPONENTS RETRIEVED AT AUTOPSY
    BAUER, TW
    GEESINK, RCT
    ZIMMERMAN, R
    MCMAHON, JT
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10): : 1439 - 1452
  • [46] FIXATION OF CEMENTLESS ACETABULAR CUPS - A RADIOGRAPHIC 4-8-YEAR STUDY OF 102 POROUS-COATED COMPONENTS
    CORDEROAMPUERO, J
    GARCIACIMBRELO, E
    MUNUERA, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (03): : 263 - 266
  • [47] KNEE ARTHROPLASTY USING A CEMENTLESS PCA PROSTHESIS WITH A POROUS-COATED CENTRAL TIBIAL STEM - CLINICAL AND RADIOGRAPHIC REVIEW AT 5 YEARS
    KIM, YH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (03): : 412 - 417
  • [48] Experimental near-field analysis for flow induced noise of a structured porous-coated cylinder
    Maryami, Reza
    Arcondoulis, Elias J. G.
    Liu, Qian
    Liu, Yu
    JOURNAL OF SOUND AND VIBRATION, 2023, 551
  • [49] MICROSCOPIC ANALYSIS OF AUTOGRAFT BONE APPLIED AT THE INTERFACE OF POROUS-COATED DEVICES IN HUMAN CANCELLOUS BONE
    HOFMANN, AA
    BLOEBAUM, RD
    RUBMAN, MH
    BACHUS, KN
    PLASTER, RL
    INTERNATIONAL ORTHOPAEDICS, 1992, 16 (04) : 349 - 358
  • [50] FINITE-ELEMENT ANALYSIS OF CRESTAL BONE LOSS AROUND POROUS-COATED DENTAL IMPLANTS
    VAILLANCOURT, H
    PILLIAR, RM
    MCCAMMOND, D
    JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (04) : 267 - 282