Dosimetric evaluation of simultaneous integrated boost during stereotactic body radiation therapy for pancreatic cancer

被引:13
|
作者
Yang, Wensha [1 ]
Reznik, Robert [1 ]
Fraass, Benedick A. [1 ]
Nissen, Nicholas [2 ]
Hendifar, Andrew [3 ]
Wachsman, Ashley [4 ]
Sandler, Howard [1 ]
Tuli, Richard [1 ]
机构
[1] Cedars Sinai Med Ctr, Dept Radiat Oncol, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Surg, Los Angeles, CA 90048 USA
[3] Cedars Sinai Med Ctr, Dept Gastrointestinal Oncol, Los Angeles, CA 90048 USA
[4] Cedars Sinai Med Ctr, Dept Cross Sect Imaging Intervent Oncol, Los Angeles, CA 90048 USA
关键词
SBRT; Pancreas; SIB; Simultaneously integrated boost; RADIOTHERAPY; GEMCITABINE; ADENOCARCINOMA; HEAD;
D O I
10.1016/j.meddos.2014.09.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Stereotactic body radiation therapy (SBRT) provides a promising way to treat locally advanced pancreatic cancer and borderline resectable pancreatic cancer. A simultaneous integrated boost (SIB) to the region of vessel abutment or encasement during SBRT has the potential to downstage otherwise likely positive surgical margins. Despite the potential benefit of using SIB-SBRT, the ability to boost is limited by the local geometry of the organs at risk (OARs), such as stomach, duodenum, and bowel (SDB), relative to tumor. In this study, we have retrospectively replanned 20 patients with 25 Gy prescribed to the planning target volume (PTV) and 33 similar to 80 Gy to the boost target volume (BTV) using an SIB technique for all patients. The number of plans and patients able to satisfy a set of clinically established constraints is analyzed. The ability to boost vessels (within the gross target volume [GTV]) is shown to correlate with the overlap volume (OLV), defined to be the overlap between the GTV + a 1(OLV1)- or 2(OLV2)-cm margin with the union of SDB. Integral dose, boost dose contrast (BDC), biologically effective BDC, tumor control probability for BTV, and normal tissue complication probabilities are used to analyze the dosimetric results. More than 65% of the cases can deliver a boost to 40 Gy while satisfying all OAR constraints. An OLV2 of 100 cm(3) is identified as the cutoff volume: for cases with OLV2 larger than 100 cm(3), it is very unlikely the case could achieve 25 Gy to the PTV while successfully meeting all the OAR constraints. (C) 2015 American Association of Medical Dosimetrists.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 50 条
  • [41] Dosimetric Consequences of Uncorrected Rotational Setup Errors During Stereotactic Body Radiation Therapy (SBRT) Treatment of Pancreatic Cancers
    Di Maso, L.
    Forbang, R. Teboh
    Zhang, Y.
    Herman, J.
    Lee, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3304 - 3304
  • [42] Monte Carlo Dose Evaluation for Pancreatic Stereotactic Body Radiation Therapy
    Gan, H.
    Zheng, D.
    Lei, Y.
    Li, S.
    Zhang, Q.
    Zhou, S.
    Li, J.
    Lin, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S363 - S363
  • [43] Dosimetric Correlations with Toxicity in the First Experience Validating Adjuvant Fractionated Stereotactic Body Radiation Therapy for Resectable Pancreatic Cancer
    Rao, A. D.
    Parkinson, R.
    Onners, B.
    Zheng, L.
    Le, D. T.
    Lutz, E.
    De Jesus-Acosta, A.
    Hruban, R. H.
    Hirose, K.
    Fishman, E. K.
    Weiss, M. J.
    Hacker-Prietz, A.
    Pawlik, T. M.
    Cameron, J. L.
    Wolfgang, C. L.
    Jaffee, E. M.
    Laheru, D. A.
    Herman, J. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E183 - E183
  • [44] Scorecards: Quantifying Dosimetric Plan Quality in Pancreatic Ductal Adenocarcinoma Stereotactic Body Radiation Therapy
    Rayn, Kareem
    Clark, Ryan
    Magliari, Anthony
    Jeffers, Brian
    Lavrova, Elizaveta
    Lozano, Ingrid Valencia
    Price, Michael J.
    Rosa, Lesley
    Horowitz, David P.
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)
  • [45] A study for the dosimetric evaluation of rotational setup error for lung stereotactic body radiation therapy
    Lee, Minsik
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 422 - 426
  • [46] Dosimetric evaluation of a rotating gamma-ray system for stereotactic body radiation therapy
    Eldib, Ahmed
    Fareed, Muhammad
    Weiss, Stephanie
    Hayes, Shelly
    Nguyen, Binh
    Mora, Grisel
    Li, Jinsheng
    Chibani, Omar
    Abdelgawad, Mahmoud
    Ma, C-M. Charlie
    JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (3-4) : 173 - 184
  • [47] Stereotactic body radiation therapy for a new lung cancer arising after pneumonectomy: dosimetric evaluation and pulmonary toxicity
    Testolin, Alessandro
    Favretto, Maria Silvia
    Cora, Stefania
    Cavedon, Carlo
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1055):
  • [48] Stereotactic Body Radiation Therapy for Pancreatic Adenocarcinoma
    Yanagihara, T.
    Jani, A.
    Oberstein, P. E.
    Chabot, J. A.
    Sherman, W. H.
    Schrope, B. A.
    Woo, Y.
    Hecht, E. M.
    Arindam, R.
    Chu, A.
    Salah, K.
    Addeo, D.
    Horowitz, D. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E140 - E140
  • [49] Integration of Stereotactic Body Radiation Therapy into the Multidisciplinary Management of Pancreatic Cancer
    Rosati, Lauren M.
    Kumar, Rachit
    Herman, Joseph M.
    SEMINARS IN RADIATION ONCOLOGY, 2017, 27 (03) : 256 - 267
  • [50] Stereotactic body radiation therapy for pancreatic cancer: Single institutional experience
    Moningi, Shalini
    Raman, Siva P.
    Dholakia, Avani Satish
    Hacker-Prietz, Amy
    Pawlik, Timothy M.
    Zheng, Lei
    Weiss, Matthew
    Laheru, Daniel A.
    Wolfgang, Christopher Lee
    Herman, Joseph M.
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (03)