摘要
Objectives: To determine (1) the optimal sites for mini-implant placement in the maxilla and the mandible based on dimensional mapping of the interradicular spaces and cortical bone thickness and (2) The effect of age and sex on the studied anatomic measurements. Material and Methods: The cone beam computed tomography images of 100 patients (46 males, 54 females) divided into two age groups (13-18 years), and (19-27 years) were used. The following interradicular measurements were performed: (1) Buccolingual bone thickness; (2) Mesiodistal spaces both buccally and palatally/lingually; and (3) Buccal and palatal/lingual cortical thicknesses. Results: In the maxilla, the highest buccolingual thickness existed between first and second molars; the highest mesiodistal buccal/palatal distances were between the second premolar and the first molar. The highest buccal cortical thickness was between the first and second premolars. The highest palatal cortical thickness was between central and lateral incisors. In the mandible, the highest buccolingual and buccal cortical thicknesses were between the first and second molars. The highest mesiodistal buccal distance was between the second premolar and the first molar. The highest mesiodistal lingual distance was between the first and second premolars. The highest lingual cortical thickness was between the canine and the first premolar. The males and the older age group had significantly higher buccolingual, buccal, and palatal cortical thicknesses at specific sites and levels in the maxilla and the mandible. Conclusions: A clinical guideline for optimal sites for mini-implant placement is suggested. Sex and age affected the anatomic measurements in certain areas in the maxilla and the mandible. (Angle Orthod. 2010;80:939-951.)
引用
收藏
页码:939 / 951
页数:13
相关论文
共 50 条
  • [41] Evaluation of Palatal Bone Thickness and Its Relationship with Palatal Vault Depth for Mini-Implant Insertion Using Cone Beam Computed Tomography Images
    Faegheh, Gholinia
    Khosravifard, Negar
    Maleki, Dina
    Hosseini, Sahar Khaje
    TURKISH JOURNAL OF ORTHODONTICS, 2022, 35 (02) : 120 - 126
  • [42] Positional Guidelines for Orthodontic Mini-implant Placement in the Anterior Alveolar Region: A Systematic Review
    AlSamak, Saeed
    Psomiadis, Simos
    Gkantidis, Nikolaos
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 470 - 479
  • [43] Optimal specimen placement in cone beam X-ray computed tomography
    Heinzl, C.
    Kastner, J.
    Amirkhamov, A.
    Groeller, E.
    Gusenbauer, C.
    NDT & E INTERNATIONAL, 2012, 50 : 42 - 49
  • [44] Cone Beam Computed Tomography (CBCT): Orthodontic Aspects
    Pazera, P.
    Bornstein, M. M.
    Jordi, P.
    Katsaros, C.
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2010, 42 (04): : 251 - 260
  • [45] Immediate Implant Placement in the Maxillary Aesthetic Zone: A Cone Beam Computed Tomography Study
    Botermans, Anna
    Liden, Anna
    de Carvalho Machado, Vinicius
    Chrcanovic, Bruno Ramos
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [46] Dental cone beam computed tomography: justification for use in planning oral implant placement
    Jacobs, Reinhilde
    Quirynen, Marc
    PERIODONTOLOGY 2000, 2014, 66 (01) : 203 - 213
  • [47] Feasibility of mini-implant insertion between mesial and distal buccal roots of a maxillary first molar: A cone-beam computed tomography imaging study
    Liu, Ji-Nan
    He, Yin-Xue
    Jia, Xue-Ting
    Huang, Rui
    Zeng, Na
    Fan, Xiao-Chuan
    Huang, Xiao-Feng
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 164 (05) : 665 - 673
  • [48] Biomechanical effect of abutment on stability of orthodontic mini-implant
    Motoyoshi, M
    Yano, S
    Tsuruoka, T
    Shimizu, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 480 - 485
  • [49] Advances in orthodontic anchorage with the use of mini-implant techniques
    Cousley, R. R. J.
    Sandlertemporary, P. J.
    BRITISH DENTAL JOURNAL, 2015, 218 (03) : 1 - 6
  • [50] Advances in orthodontic anchorage with the use of mini-implant techniques
    R. R. J. Cousley
    P. J. Sandler
    British Dental Journal, 2015, 218 : E4 - E4