Evaluation of the medtronic (Driver) cobalt-chromium alloy coronary stent system

被引:76
|
作者
Sketch, MH
Ball, M
Rutherford, B
Popma, JJ
Russell, C
Kereiakes, DJ
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
[2] St Vincent Hosp, Heart Ctr Indiana, Indianapolis, IN USA
[3] St Lukes Hosp, Kansas City, MO 64111 USA
[4] Brigham & Womens Hosp, Boston, MA 02115 USA
[5] Medtron Vasc Clin Res Dept, Santa Rosa, CA USA
[6] Christ Hosp, Lindner Ctr Res & Educ, Ohio Heart Hlth Ctr, Cincinnati, OH 45219 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2005年 / 95卷 / 01期
关键词
D O I
10.1016/j.amjcard.2004.08.055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Driver Registry was a prospective, multicenter, non-randomized study to evaluate the clinical safety and efficacy of the Driver cobalt-chromium alloy stent. Use of the cobalt-chromium alloy in place of stainless steel offers enhanced visibility and radial strength with thinner structural elements. The registry enrolled 298 patients with symptomatic ischemic heart disease attributable to de novo or restenotic nonstented native lesions of a single vessel amenable to percutaneous stenting. The primary composite end point was the incidence of major adverse cardiac events (death, myocardial infarction, emergency bypass surgery, or target lesion revascularization) 180 days after enrollment. Quantitative coronary angiography was performed. before and after the index stent deployment and repeated at 6 months in 83 patients. Mean patient age was 62.6 years, mean reference vessel diameter was 3.07 mm before the procedure, and mean lesion length was 11.04 mm. Fifty-one patients received multiple stents. Angiographic success rate was 100% and procedural success rate was 98.3%. Cumulative incidence of major adverse cardiac events was 5.7% and target lesion revascularization was 3.4% at 180 days. In-stent late loss was 0.94 mm at 180 days, and no subacute stent thromboses were observed. This registry demonstrated the safety and efficacy of this novel. coronary stent platform. (C)2005 by Excerpta Medica Inc.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [41] Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy
    Minesaki, Yoshito
    Murahara, Sadaaki
    Kajihara, Yutaro
    Takenouchi, Yoshihisa
    Tanaka, Takuo
    Suzuki, Shiro
    Minami, Hiroyuki
    JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (01): : 1 - 8
  • [42] ROENTGENOLOGICAL DETECTION OF CASTING DEFECTS IN COBALT-CHROMIUM ALLOY FRAMEWORKS
    WICTORIN, L
    JULIN, P
    MOLLERSTEN, L
    JOURNAL OF ORAL REHABILITATION, 1979, 6 (02) : 137 - 146
  • [43] ROENTGENOLOGIC DETECTION OF CASTING DEFECTS IN COBALT-CHROMIUM ALLOY FRAMEWORK
    WICTORIN, L
    MOLLERSTEN, L
    JULIN, P
    JOURNAL OF DENTAL RESEARCH, 1977, 56 : A51 - A51
  • [44] A surface PXRD study of a cobalt-chromium casting alloy.
    O'Brien, S
    Morris, M
    Ray, N
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1285 - 1285
  • [45] Electrochemical and mechanical properties of cobalt-chromium dental alloy joints
    Zupancic, Rok
    Legat, Andraz
    Funduk, Nenad
    MATERIALI IN TEHNOLOGIJE, 2007, 41 (06): : 295 - 300
  • [46] BONE APPOSITION TO PLASMA-SPRAYED COBALT-CHROMIUM ALLOY
    LUCKEY, HA
    LAMPRECHT, EG
    WALT, MJ
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (05): : 557 - 575
  • [48] Rotary instruments used for machining of cobalt-chromium alloy.
    Radford, DR
    Xenodimitropoulou, G
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 933 - 933
  • [49] Laser welding of a cobalt-chromium removable partial denture alloy
    NaBadalung, DP
    Nicholls, JI
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (03): : 285 - 290
  • [50] A NEW TITANIUM-BEARING COBALT-CHROMIUM DENTAL ALLOY
    RUDIGER, O
    HOFFMANN, A
    HIRSCHFELD, D
    TECHNISCHE MITTEILUNGEN KRUPP FORSCHUNGSBERICHTE, 1970, 28 (01): : 9 - +