Motion-robust intensity-modulated proton therapy for distal esophageal cancer

被引:59
|
作者
Yu, Jen [1 ,2 ,3 ]
Zhang, Xiaodong [1 ,2 ]
Liao, Li [4 ]
Li, Heng [1 ,2 ]
Zhu, Ronald [1 ,2 ]
Park, Peter C. [2 ]
Sahoo, Narayan [1 ,2 ]
Gillin, Michael [1 ,2 ]
Li, Yupeng [5 ]
Chang, Joe Y. [6 ]
Komaki, Ritsuko [6 ]
Lin, Steven H. [6 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Proton Therapy Ctr, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Univ Maryland, Sch Med, Maryland Proton Treatment Ctr, Dept Radiat Oncol, Baltimore, MD 21201 USA
[4] Univ Houston, Dept Ind Engn, Houston, TX 77004 USA
[5] Varian Med Syst, Appl Res, Palo Alto, CA 94304 USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
关键词
IMPT; WET; 4D-robustness optimization; distal esophageal cancer; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; ION-BEAM THERAPY; PARTICLE THERAPY; LIVER-TUMORS; LUNG; MITIGATION; QUANTIFICATION; RADIOTHERAPY; IRRADIATION; SIMULATION;
D O I
10.1118/1.4940789
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop methods for evaluation and mitigation of dosimetric impact due to respiratory and diaphragmatic motion during free breathing in treatment of distal esophageal cancers using intensity-modulated proton therapy (IMPT). Methods: This was a retrospective study on 11 patients with distal esophageal cancer. For each patient, four-dimensional computed tomography (4D CT) data were acquired, and a nominal dose was calculated on the average phase of the 4D CT. The changes of water equivalent thickness (Delta WET) to cover the treatment volume from the peak of inspiration to the valley of expiration were calculated for a full range of beam angle rotation. Two IMPT plans were calculated: one at beam angles corresponding to small Delta WET and one at beam angles corresponding to large Delta WET. Four patients were selected for the calculation of 4D-robustness-optimized IMPT plans due to large motion-induced dose errors generated in conventional IMPT. To quantitatively evaluate motion-induced dose deviation, the authors calculated the lowest dose received by 95% (D95) of the internal clinical target volume for the nominal dose, the D95 calculated on the maximum inhale and exhale phases of 4D CT (D-CT0 and D-CT50), the 4D composite dose, and the 4D dynamic dose for a single fraction. Results: The dose deviation increased with the average Delta WET of the implemented beams, Delta WETave. When Delta WETave was less than 5 mm, the dose error was less than 1 cobalt gray equivalent based on D-CT0 and D-CT50. The dose deviation determined on the basis of D-CT0 and D-CT50 was proportionally larger than that determined on the basis of the 4D composite dose. The 4D-robustness-optimized IMPT plans notably reduced the overall dose deviation of multiple fractions and the dose deviation caused by the interplay effect in a single fraction. Conclusions: In IMPT for distal esophageal cancer, Delta WET analysis can be used to select the beam angles that are least affected by respiratory and diaphragmatic motion. To further reduce dose deviation, the 4D-robustness optimization can be implemented for IMPT planning. Calculation of D-CT0 and D-CT50 is a conservative method to estimate the motion-induced dose errors. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:1111 / 1118
页数:8
相关论文
共 50 条
  • [1] 4D Robust Optimization in Small Spot Intensity-Modulated Proton Therapy (IMPT) for Distal Esophageal Carcinoma
    Feng, H.
    Shan, J.
    Ashman, J.
    Rule, W.
    Bhangoo, R.
    Yu, N.
    Chiang, J.
    Fatyga, M.
    Wong, W.
    Schild, S.
    Sio, T.
    Liu, W.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Beam angle comparison for distal esophageal carcinoma patients treated with intensity-modulated proton therapy
    Feng, Hongying
    Sio, Terence T.
    Rule, William G.
    Bhangoo, Ronik S.
    Lara, Pedro
    Patrick, Christopher L.
    Korte, Shawn
    Fatyga, Mirek
    Wong, William W.
    Schild, Steven E.
    Ashman, Jonathan B.
    Liu, Wei
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 141 - 152
  • [3] Robust Beam Orientation Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Neph, R.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E257 - E258
  • [4] High Fidelity Robust Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E641 - E641
  • [5] Biological Based Robust Optimization for Intensity-Modulated Proton Therapy
    Bai, X.
    Lim, G.
    Grosshans, D.
    Mohan, R.
    Cao, W.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E643 - E643
  • [6] Robust beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Neph, Ryan
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    [J]. MEDICAL PHYSICS, 2019, 46 (08) : 3356 - 3370
  • [7] Dosimetric comparison of magnetic resonance-guided radiation therapy, intensity-modulated proton therapy and volumetric-modulated arc therapy for distal esophageal cancer
    Barsky, Andrew R.
    George, Jerry
    Wroe, Andrew J.
    Mittauer, Kathryn E.
    Kaiser, Adeel
    Herrera, Roberto
    Yu, Jen
    Gutierrez, Alonso N.
    Alvarez, Diane
    McCulloch, James
    Kasper, Michael E.
    Mehta, Minesh P.
    Chuong, Michael D.
    [J]. MEDICAL DOSIMETRY, 2024, 49 (02) : 121 - 126
  • [8] Robust Management of Motion Uncertainty in Intensity-Modulated Radiation Therapy
    Bortfeld, Thomas
    Chan, Timothy C. Y.
    Trofimov, Alexei
    Tsitsiklis, John N.
    [J]. OPERATIONS RESEARCH, 2008, 56 (06) : 1461 - 1473
  • [9] Technical Note: 4D robust optimization in small spot intensity-modulated proton therapy (IMPT) for distal esophageal carcinoma
    Feng, Hongying
    Shan, Jie
    Ashman, Jonathan B.
    Rule, William G.
    Bhangoo, Ronik S.
    Yu, Nathan Y.
    Chiang, Jennifer
    Fatyga, Mirek
    Wong, William W.
    Schild, Steven E.
    Sio, Terence T.
    Liu, Wei
    [J]. MEDICAL PHYSICS, 2021, 48 (08) : 4636 - 4647
  • [10] Proton Therapy for Nasopharyngeal Cancer: A Matched Case-control Study of Intensity-Modulated Proton Therapy and Intensity-Modulated Photon Therapy
    Li, X.
    Lee, A.
    Lee, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (05): : 1138 - 1139