Temperature and energy performance of refrigerated retail display and commercial catering cabinets under test conditions

被引:55
|
作者
Evans, J. A. [1 ]
Scarcelli, S. [1 ]
Swain, M. V. L. [1 ]
机构
[1] Univ Bristol, FRPERC, Bristol BS40 5DU, Avon, England
关键词
refrigeration; commercial application; display cabinet; test; measurement; performance; temperature; energy consumption;
D O I
10.1016/j.ijrefrig.2006.10.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analysis of the performance of well freezers, chest freezers, frozen and chilled door cabinets (solid or glass door) and open fronted chilled cabinets under EN441 test conditions demonstrated that maximum temperatures in cabinets were generally in the most exposed (to ambient) areas and that minimum temperatures were located in the least exposed areas. Detailed positions of maximum and minimum temperature varied between cabinet types. In chest freezers 95% of the maximum temperature positions were located in the top layer and 95% of the minimum temperature positions were located in the middle layer of the cabinets. In full door frozen cabinets the maximum temperature position was in the majority of cases on the top shelf (64%) with most maximum packs being at the front of the top shelf (53%). In the chilled full door cabinets 94% of the maximum temperature packs were situated at the front of the cabinet. In open fronted cabinets the majority of maximum temperature packs (97%) were located at the front of the cabinet, the largest number (60%) being at the front of the base of the cabinet. In well cabinets the majority of maximum temperature packs (81%) were located in the top layer of the cabinet and the majority (91%) of minimum temperature packs were located in the bottom of the cabinet. Large differences in energy consumed by cabinets of similar size and temperature performance were found indicating that large reductions in energy and CO2 emissions could be achieved by selection of the most efficient cabinets. (c) 2006 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:398 / 408
页数:11
相关论文
共 50 条
  • [1] Experimental and numerical investigation of the performance of retail refrigerated display cabinets
    Chaomuang, Nattawut
    Flick, Denis
    Laguerre, Onrawee
    [J]. TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2017, 70 : 95 - 104
  • [2] Temperature and energy performance of open refrigerated display cabinets using heat pipe shelves
    Jouhara, H.
    Nannou, T.
    Ghazal, H.
    Kayyali, R.
    Tassou, S. A.
    Lester, S.
    [J]. PROCEEDINGS OF 1ST INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS (ICFES 2017), INCLUDING SYMPOSIUM ON HEAT RECOVERY AND EFFICIENT CONVERSION AND UTILISATION OF WASTE HEAT, 2017, 123 : 273 - 280
  • [3] CERTIFICATION OF PERFORMANCE OF REFRIGERATED DISPLAY CABINETS
    Marinhas, S.
    [J]. 23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 24 - 29
  • [4] THE DESIGN OF MEDICAL OPEN REFRIGERATED DISPLAY CABINETS LABORATORY WITH THE PERFORMANCE TEST
    Chen, J. B.
    Kong, X. S.
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 118 : 114 - 114
  • [5] Performance and conditions of use of refrigerated display cabinets among producer/vendors of foodstuffs
    Morelli, Elisabeth
    Noel, Veronique
    Rosset, Philippe
    Poumeyrol, Gerard
    [J]. FOOD CONTROL, 2012, 26 (02) : 363 - 368
  • [6] LIFE CYCLE ASSESSMENT OF RETAIL REFRIGERATED DISPLAY CABINETS REACHING END OF LIFE
    Bibalou, D.
    Chaer, I.
    Maidment, G.
    Andrews, D.
    Longhurst, M.
    [J]. 23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2431 - +
  • [7] NOVEL AEROFOILS USED FOR REDUCING ENERGY CONSUMPTION AND IMPROVING TEMPERATURE PERFORMANCE FOR MULTI-DECK REFRIGERATED DISPLAY CABINETS
    Foster, A.
    McAndrew, P.
    Evans, J.
    [J]. 3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 109 - 116
  • [8] The Design of the Performance Test Laboratory of Open Refrigerated Display Cabinets Based on Enthalpy Potential Method
    Li, Shuai
    Li, Lei
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 1599 - 1602
  • [9] PERFORMANCE EVALUATION METHOD OF HEAT PUMP DRIVEN REFRIGERATED DISPLAY CABINETS
    Ohno, Keisuke
    Redo, Mark Anthony
    Giannetti, Niccolo
    Yamaguchi, Seiichi
    Saito, Kiyoshi
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 294 - 301
  • [10] Influence of operating conditions on the temperature performance of a closed refrigerated display cabinet
    Chaomuang, Nattawut
    Flick, Denis
    Denis, Alain
    Laguerre, Onrawee
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 103 : 32 - 41