A beam hardening correction for X-ray microtomography

被引:15
|
作者
de Paiva, RF [1 ]
Lynch, J [1 ]
Rosenberg, E [1 ]
Bisiaux, M [1 ]
机构
[1] Inst Francais Petr, F-92500 Rueil Malmaison, France
关键词
X-rays; microtomography; quantification;
D O I
10.1016/S0963-8695(97)00032-7
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We propose a correction of the transmitted intensities in X-ray microscopy allowing improved quantification for polychromatic sources, particularly in tomographic reconstruction. The correction is based on the application of Beer's law for each energy present in the source spectrum. Knowledge of the source spectrum and the average specimen composition are used. The correction is demonstrated on a chemically homogeneous specimen (a glass capillary filled with glass beads) and on a polyphasic oil reservoir rock sample. In the former, detection of 20 mu m defects is demonstrated. In the latter, different minerals, quartz, feldspath and kaolinite, can be discriminated and their distributions mapped. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 50 条
  • [21] X-RAY MICROTOMOGRAPHY
    ELLIOTT, JC
    DOVER, SD
    JOURNAL OF MICROSCOPY, 1982, 126 (MAY) : 211 - 213
  • [22] X-ray microtomography
    Landis, Eric N.
    Keane, Denis T.
    MATERIALS CHARACTERIZATION, 2010, 61 (12) : 1305 - 1316
  • [23] BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY
    BROOKS, RA
    DICHIRO, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03): : 390 - 398
  • [24] Influence of beam hardening artifact in bone interface contact evaluation by 3D X-ray microtomography
    Lima, I.
    Marquezan, M.
    Souza, M. M. G.
    Sant'Anna, E. F.
    Lopes, R. T.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 399 - 402
  • [25] CONE-BEAM X-RAY MICROTOMOGRAPHY OF SMALL SPECIMENS
    MACHIN, K
    WEBB, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1639 - 1657
  • [26] REVIEW ON THE DEVELOPMENT OF CONE-BEAM X-RAY MICROTOMOGRAPHY
    CHENG, PC
    LIN, TH
    WANG, G
    SHINOZAKI, DM
    KIM, HG
    NEWBERRY, SP
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 559 - 566
  • [27] Fast algorithm for X-ray cone-beam microtomography
    Shih, A
    Wang, G
    Cheng, PC
    MICROSCOPY AND MICROANALYSIS, 2001, 7 (01) : 13 - 23
  • [28] Experimental system for X-ray cone-beam microtomography
    Pan, S
    Liou, W
    Shih, A
    Park, MS
    Wang, G
    Newberry, SP
    Kim, H
    Shinozaki, DM
    Cheng, PC
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (01) : 56 - 62
  • [29] Beam hardening-respecting flat field correction of digital X-ray detectors
    Yu, Yongjian
    Wang, Jue
    2012 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2012), 2012, : 2085 - 2088
  • [30] Beam hardening simulated correction research for X-ray TICT in testing composites workpiece
    Peng Guang-han
    Cai Xin-hua
    Han Zhong
    Zhou Ri-feng
    Yang Xue-heng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (09) : 1882 - 1885