摘要
The Monte Carlo codes EGS4 and MCNP have been compared when calculating radiotherapy depth doses in water. The aims of the work were to study (i) the differences between calculated depth doses in water for a range of monoenergetic photon energies and (ii) the relative efficiency of the two codes for different electron transport energy cut-offs. The depth doses from the two codes agree with each other within the statistical uncertainties of the calculations (1-2%). The relative depth doses also agree with data tabulated in the British Journal of Radiology Supplement 25. A discrepancy in the dose build-up region may by attributed to the different electron transport algorithms used by EGS4 and MCNP. This discrepancy is considerably reduced when the improved electron transport routines are used in the latest (4B) version of MCNP. Timing calculations show that EGS4 is at least 50% faster than MCNP for the geometries used in the simulations.
引用
收藏
页码:1351 / 1357
页数:7
相关论文
共 50 条
  • [41] DOSE3D: EGS4 Monte Carlo code-based software for internal radionuclide dosimetry
    Clairand, I
    Ricard, M
    Gouriou, J
    Di Paola, M
    Aubert, B
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (09) : 1517 - 1523
  • [42] Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    Kawrakow, I
    MEDICAL PHYSICS, 2000, 27 (03) : 485 - 498
  • [43] Anisotropy function for 192Ir low-dose-rate brachytherapy sources:: an EGS4 Monte Carlo study
    Capote, R
    Mainegra, E
    López, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1487 - 1499
  • [44] Application of the EGS4 Monte Carlo code to the study of gamma-ray exposure buildup factors up to 40 MFP
    Hirayama, H
    PROCEEDINGS OF THE 1996 TOPICAL MEETING RADIATION PROTECTION & SHIELDING, VOLS 1 AND 2, 1996, 1-2 : 516 - 523
  • [45] Comparison of the TRIPOLI-4®, DIANE, and MCNP6 Monte Carlo Codes on the Barber & George Benchmark for Photonuclear Reactions
    Tuyet, Tran Kim
    Jinaphanh, Alexis
    Jouanne, Cedric
    Gerardin, Frederic
    Lemaire, Sebastien
    Zoia, Andrea
    NUCLEAR SCIENCE AND ENGINEERING, 2024, 198 (02) : 319 - 335
  • [46] Analytical calculation of the portal scatter to primary dose ratio: an EGS4 Monte Carlo and experimental validation at large air gaps
    Ozard, SR
    Grein, EE
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06): : 1719 - 1736
  • [47] Dose distribution from x-ray microbeam arrays applied to radiation therapy: An EGS4 Monte Carlo study
    De Felici, M
    Felici, R
    del Rio, MS
    Ferrero, C
    Bacarian, T
    Dilmanian, FA
    MEDICAL PHYSICS, 2005, 32 (08) : 2455 - 2463
  • [48] Monte Carlo dose voxel kernel calculations of beta-emitting and Auger-emitting radionuclides for internal dosimetry: A comparison between EGSnrcMP and EGS4
    Strigari, Lidia
    Menghi, Enrico
    D'Andrea, Marco
    Benassi, Marcello
    MEDICAL PHYSICS, 2006, 33 (09) : 3383 - 3389
  • [49] CALCULATION OF RADIATION-DOSE AT A BONE-TO-MARROW INTERFACE USING MONTE-CARLO MODELING TECHNIQUES (EGS4)
    JOHNSON, JC
    LANGHORST, SM
    LOYALKA, SK
    VOLKERT, WA
    KETRING, AR
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (04) : 623 - 628
  • [50] COMPARISON OF SCIENTIFIC COMPUTING PLATFORMS FOR MCNP4A MONTE-CARLO CALCULATIONS
    HENDRICKS, JS
    BROCKHOFF, RC
    NUCLEAR SCIENCE AND ENGINEERING, 1994, 116 (04) : 269 - 277