Destruction of hazardous air pollutants using a fast rise time pulsed corona reactor

被引:26
|
作者
Korzekwa, RA
Grothaus, MG
Hutcherson, RK
Roush, RA
Brown, R
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] SW Res Inst, San Antonio, TX 78228 USA
[3] OSRAM Sylvania Inc, Beverly, MA 01915 USA
[4] Fed Bur Invest, Engn Res Facil, Quantico, VA 22135 USA
[5] USN, Ctr Surface Warfare, Dahlgren, VA 22448 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1998年 / 69卷 / 04期
关键词
D O I
10.1063/1.1148859
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Increasingly stringent environmental regulation imposed on both the military and civilian sectors has created a growing demand for alternative abatement methods for a variety of hazardous compounds. One alternative, the nonthermal plasma, shows promise of providing an efficient means for the destruction of dilute concentrations of hazardous air pollutants. The Dahlgren Laboratory of the Naval Surface Warfare Center has extensively investigated one type of nonthermal plasma discharge, the pulsed corona reactor, for the destruction of volatile organic compounds and chemical warfare agents. In this reactor, a fast rise time (similar to 10 ns), short duration (<100 ns), high-voltage pulse is repetitively delivered to a wire-cylinder electrode geometry, thereby producing a multitude of streamer discharges along its length. The resulting nonthermal plasma contains highly reactive chemical radicals which can interact with and destroy the hazardous molecules entrained in the ambient atmosphere flowing through the reactor volume. Increased electrical efficiency was obtained using a combination of high efficiency constant-current capacitor-charging high repetition-rate spark gap switching, and resonant energy transfer to the reactor. Promising results have been obtained for toluene, methylene chloride, and dichlorodifluoromethane in air at concentrations of a few hundred parts per million. The device has been operated at voltages up to 30 kV, pulse repetition rates up to 1.4 kHz, and flow rates up to 60 l/min. Detailed electrical measurements have been made to properly characterize the electrical properties of the pulsed corona reactor and to validate subsequent improvements in the reactor energy efficiency. (C) 1998 American Institute of Physics.
引用
收藏
页码:1886 / 1892
页数:7
相关论文
共 50 条
  • [21] Decomposition of VOC in air using a streamer corona discharge reactor combined with catalyst
    Ohkubo, T
    Li, D
    Yakushiji, D
    Kanazawa, S
    Nomoto, Y
    [J]. JOURNAL OF ADVANCED OXIDATION TECHNOLOGIES, 2003, 6 (01) : 75 - 79
  • [22] Removal of acetaldehyde in air using a wetted-wall corona discharge reactor
    Faungnawakij, K
    Sano, N
    Yamamoto, D
    Kanki, T
    Charinpanitkul, T
    Tanthapanichakoon, W
    [J]. CHEMICAL ENGINEERING JOURNAL, 2004, 103 (1-3) : 115 - 122
  • [23] STRUCTURE INVESTIGATION BY NEUTRON DIFFRACTION USING A PULSED FAST REACTOR (IBR)
    NITTS, VV
    PAPULOVA, ZG
    SOSNOVSKAYA, I
    SOSNOVSKII, E
    [J]. SOVIET PHYSICS-SOLID STATE, 1964, 6 (05): : 1070 - 1074
  • [24] STRUCTURE INVESTIGATION BY NEUTRON DIFFRACTION USING A PULSED FAST REACTOR (IBR)
    NITTS, VV
    PAPULOVA, ZG
    SOSNOVSK.I
    SOSNOVSK.E
    [J]. SOVIET PHYSICS SOLID STATE,USSR, 1964, 6 (05): : 1070 - +
  • [25] Energy injected in multi-tip pulsed corona discharge reactor in air at atmospheric pressure for pollution control
    Abahazem, Alyen
    Guedah, Hasna
    Merbahi, Nofel
    Yousfi, Mohamed
    Eichwald, Olivier
    Ihlal, Ahmed
    [J]. MATERIALS TODAY-PROCEEDINGS, 2015, 2 (09) : 4694 - 4700
  • [28] Effect of structure of corona-discharge reactor on removal of dilute gaseous pollutants using selective electron attachment
    Tanthapanichakoon, W
    Larpsuriyakul, K
    Charinpanitkul, T
    Sano, N
    Tamon, H
    Okazaki, M
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1998, 31 (01) : 7 - 13
  • [29] Selection of Priority Monitoring Areas for Hazardous Air Pollutants (HAPs) in Seoul using Geographic Information System
    Kim, Seong-Joon
    Park, Hyeon-Jin
    Lee, Sang-Jin
    Kim, Chang-Hyeok
    Lee, Seung-Bok
    Choi, Sung-Deuk
    [J]. JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2018, 34 (02) : 223 - 232
  • [30] Characterization of the Chronic Risk and Hazard of Hazardous Air Pollutants in the United States Using Ambient Monitoring Data
    McCarthy, Michael C.
    O'Brien, Theresa E.
    Charrier, Jessica G.
    Hather, Hilary R.
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2009, 117 (05) : 790 - 796