Investigation of preferred viscosity of irreversible hydrocolloid on preliminary impression for edentulism

被引:1
|
作者
Maruo, Y
Irie, M
Nishigawa, G
Oka, M
Minagi, S
Suzuki, K
机构
[1] Okayama Univ, Grad Sch Med & Dent, Dept Occlusal & Oral Funct Rehabil, Okayama 7008525, Japan
[2] Okayama Univ, Grad Sch Med & Dent, Dept Biomat, Okayama 7008525, Japan
[3] Okayama Univ, Hosp Dent, Clin Div Removable Prosthodont, Okayama 7008525, Japan
关键词
irreversible hydrocolloid; edentulism; preliminary impression;
D O I
10.4012/dmj.23.395
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aims to investigate the preferred viscosity of irreversible hydrocolloid used in the preliminary impression for edentulism. Thirteen modalities of irreversible hydrocolloid were prepared by changing the W/P ratio. Discrimination test for the preferred viscosity was performed on 11 prosthodontists (10.4 +/- 5.3 years of prosthetic experience). The parameter of discrimination test (P%) was calculated as the ratio of the number of adequate tests to the total number of tests. The P% and apparent viscosity coefficient (etaa) values measured by rheometer demonstrated good correlation (Y = -35.8X(2)+ 118.4X-22.8, r=0.86, p<0.01). Prosthodontists could judge the preferred viscosity based on their clinical experiences. On the preliminary impression for edentulism, the preferred viscosity demonstrated in vitro using a polyurethane maxilla model was 1.21 x 10(3) Pa.s.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 50 条
  • [41] AN INVITRO STUDY OF THE ANTIBACTERIAL AND ANTIFUNGAL PROPERTIES OF AN IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIAL IMPREGNATED WITH DISINFECTANT
    TOBIAS, RS
    BROWNE, RM
    WILSON, CA
    JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (05): : 601 - 605
  • [42] DIMENSIONAL STABILITY OF IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS AS A FUNCTION OF POURING TIME: A SYSTEMATIC REVIEW
    Nassar, Usama
    Aziz, Tehnia
    Flores-Mir, Carlos
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (02): : 126 - 133
  • [43] Use of irreversible hydrocolloid impression material to correct a defect in complete denture definitive impressions
    Oh, Won-suk
    Park, Ju-mi
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03): : 255 - 256
  • [44] Dimensional Accuracy of 2 Irreversible Hydrocolloid Alternative Impression Materials with Immediate and Delayed Pouring
    Nassar, Usama
    Hussein, Bayan
    Oko, Andrea
    Carey, Jason P.
    Flores-Mir, Carlos
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2012, 78
  • [45] EFFECT ON SURFACE DETAIL OF CASTS WHEN IRREVERSIBLE HYDROCOLLOID WAS WETTED BEFORE IMPRESSION MAKING
    MORRIS, JC
    KHAN, Z
    FIELDS, H
    JOURNAL OF PROSTHETIC DENTISTRY, 1983, 49 (03): : 328 - 330
  • [46] THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF STONE CASTS POURED FROM IRREVERSIBLE HYDROCOLLOID IMPRESSIONS
    MENDEZ, AJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (03): : 383 - 388
  • [47] Disinfection procedures: Their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material
    Rentzia, A.
    Coleman, D. C.
    O'Donnell, M. J.
    Dowling, A. H.
    O'Sullivan, M.
    JOURNAL OF DENTISTRY, 2011, 39 (02) : 133 - 140
  • [48] Effect of storage time on mechanical properties of extended-pour irreversible hydrocolloid impression materials
    Sahin, Volkan
    Jodati, Hossein
    Evis, Zafer
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (01): : 69 - 74
  • [49] Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
    Savabi, Omid
    Nejatidanesh, Farahnaz
    Bagheri, Kamran Poshang
    Karimi, Leila
    Savabi, Ghazal
    INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE, 2018, 9
  • [50] A study on the surface reproduction of dental stones with pH changes of dental irreversible hydrocolloid impression materials
    Byun, JD
    Kim, CW
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1190 - 1190