Development of a novel rapid non-invasive screening test for coeliac disease

被引:75
|
作者
Baldas, V
Tommasini, A
Trevisiol, C
Berti, I
Fasano, A
Sblattero, D
Bradbury, A
Marzari, R
Barillari, G
Ventura, A
Not, T
机构
[1] IRCCS Burlo Garofolo, Dept Pediat, Trieste, Italy
[2] Univ Maryland, Div Pediat Gastroenterol & Nutr, Baltimore, MD 21201 USA
[3] Scuola Int Super Studi Avanzati, Trieste, Italy
[4] Dept Biol, Trieste, Italy
[5] City Hosp, Blood Transfus Serv, Udine, Italy
关键词
coeliac disease; dot blot immunobinding assay; recombinant human tissue transglutaminase;
D O I
10.1136/gut.47.5.628
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background-Coeliac disease is one of the commonest underdiagnosed diseases in general practice. The autoantigen recognised by the sera of patients with coeliac disease has recently been identified as tissue transglutaminase. Aims-We evaluated a simple noninvasive immunological dot blot assay for coeliac disease, suitable for use by the general physician in the ambulatory setting. The sensitivity and specificity of this dot blot assay based an recognition of recombinant human transglutaminase were compared with those of antiendomysial antibodies and an enzyme Linked immunosorbent assay. Methods-Serum samples were analysed from 64 healthy controls, 58 first degree relatives of coeliacs, 74 diseased controls, and 70 biopsy confirmed untreated patients with coeliac disease. Dot blot assay and enzyme linked immunosorbent assay were performed using recombinant human transglutaminase as antigen. Results-The dot blot assay, which can be performed in 20 minutes, was positive in all 70 untreated coeliacs (sensitivity 100%). Among the three control groups, there were three false positive tests by dot blot (specificity 98%), all belonging to the group of healthy subjects. The antiendomysial antibodies test missed five untreated coeliac patients (sensitivity 93%) and was negative in all three control groups (specificity 100%). The specificity of the immunosorbent assay was 99% for IgA and 98% for IgG, while sensitivity was 93% for IgA, 47% for IgG, and 100% for IgA and IgG combined. Conclusions-The dot blot assay is highly accurate in detecting untreated subjects with coeliac disease and can be performed in the general physician's medical office during the course of a routine examination. This innovative test is a practical, reliable alternative to both the immunofluorescent based antiendomysial test and immunosorbent assay for detection of transglutaminase antibodies for the diagnosis of coeliac disease.
引用
收藏
页码:628 / 631
页数:4
相关论文
共 50 条
  • [21] Assessing receptivity in the endometrium: the need for a rapid, non-invasive test
    Edgell, Tracey A.
    Rombauts, Luk J. F.
    Salamonsen, Lois A.
    REPRODUCTIVE BIOMEDICINE ONLINE, 2013, 27 (05) : 486 - 496
  • [22] Non-Invasive Breath Analysis for Disease Screening and Diagnoses
    Jung, Hyun Jin
    Priefer, Ronny
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [23] NON-INVASIVE SCREENING-TESTS FOR PANCREATIC DISEASE
    MITCHELL, CJ
    IRVING, HC
    ROBERTSON, DRC
    FEAR, J
    KELLEHER, J
    BARK, M
    LOSOWSKY, MS
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1981, 5 (10): : 936 - 939
  • [24] Non-invasive Screening Tool for Chronic Kidney Disease
    Saxena, Anita
    Gupta, Amit
    Abraham, Georgi
    Sakhuja, Vinay
    Jha, V.
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2015, 26 (06) : 1311 - 1313
  • [25] NON-INVASIVE SCREENING-TEST FOR ESOPHAGEAL MOTOR DISORDERS
    RUSSELL, COH
    GANNAN, R
    HOLMES, E
    POPE, CE
    HILL, LD
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1980, 74 (01): : 91 - 91
  • [26] A novel non-invasive prenatal test technique with genosensor
    Kokbas, Umut
    Tuli, Abdullah
    Kayrin, Levent
    CUKUROVA MEDICAL JOURNAL, 2021, 46 (01): : 208 - 215
  • [27] Vascular screening in andropause: Non-invasive investigations in vascular disease screening
    Belcaro, G
    Nicolaides, AN
    Cesarone, MR
    De Sanctis, MT
    Geroulakos, G
    Lennox, A
    Griffin, M
    Incandela, L
    CURRENT MEDICAL RESEARCH AND OPINION, 2000, 16 : S68 - S71
  • [28] Myocardial strain analysis as a non-invasive screening test in the diagnosis of stable coronary artery disease
    Nehzat Akiash
    Mohammad Mohammadi
    Hoda Mombeini
    Akbar Nikpajouh
    The Egyptian Heart Journal, 73
  • [29] Myocardial strain analysis as a non-invasive screening test in the diagnosis of stable coronary artery disease
    Akiash, Nehzat
    Mohammadi, Mohammad
    Mombeini, Hoda
    Nikpajouh, Akbar
    EGYPTIAN HEART JOURNAL, 2021, 73 (01):
  • [30] Screening utility of a rapid non-invasive dry eye assessment algorithm
    Wang, Michael T. M.
    Xue, Ally L.
    Craig, Jennifer P.
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (05): : 497 - 501