The Compressed Sensing MP2RAGE as a Surrogate to the MPRAGE for Neuroimaging at 3 T

被引:8
|
作者
Trotier, Aurelien J. [1 ]
Dilharreguy, Bixente [2 ]
Anandra, Serge [2 ]
Corbin, Nadege [1 ,3 ]
Lefrancois, William [1 ]
Ozenne, Valery [1 ]
Miraux, Sylvain [1 ]
Ribot, Emeline J. [1 ]
机构
[1] Univ Bordeaux, Ctr Resonance Magnet Syst Biol, UMR5536, CNRS, Bordeaux, France
[2] Univ Bordeaux, UMS3767, Biomed Imaging Facil pIBIO, CNRS, Bordeaux, France
[3] UCL, Wellcome Ctr Human Neumimaging, UCL Queen Sq Inst Neurol, London, England
关键词
MP2RAGE; compressed sensing; MPRAGE; volumetry; T-1; mapping; repeatability; NMR RELAXATION-TIMES; MULTIPLE-SCLEROSIS; HUMAN BRAIN; LONGITUDINAL RELAXATION; SPOILED FLASH; MRI; T-1; GRAY; R1;
D O I
10.1097/RLI.0000000000000849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) sequence provides quantitative T-1 maps in addition to high-contrast morphological images. Advanced acceleration techniques such as compressed sensing (CS) allow its acquisition time to be compatible with clinical applications. To consider its routine use in future neuroimaging protocols, the repeatability of the segmented brain structures was evaluated and compared with the standard morphological sequence (magnetization-prepared rapid gradient echo [MPRAGE]). The repeatability of the T-1 measurements was also assessed. Materials and Methods Thirteen healthy volunteers were scanned either 3 or 4 times at several days of interval, on a 3 T clinical scanner, with the 2 sequences (CS-MP2RAGE and MPRAGE), set with the same spatial resolution (0.8-mm isotropic) and scan duration (6 minutes 21 seconds). The reconstruction time of the CS-MP2RAGE outputs (including the 2 echo images, the MP2RAGE image, and the T-1 map) was 3 minutes 33 seconds, using an open-source in-house algorithm implemented in the Gadgetron framework. Both precision and variability of volume measurements obtained from CAT12 and VolBrain were assessed. The T-1 accuracy and repeatability were measured on phantoms and on humans and were compared with literature. Volumes obtained from the CS-MP2RAGE and the MPRAGE images were compared using Student t tests (P < 0.05 was considered significant). Results The CS-MP2RAGE acquisition provided morphological images of the same quality and higher contrasts than the standard MPRAGE images. Similar intravolunteer variabilities were obtained with the CS-MP2RAGE and the MPRAGE segmentations. In addition, high-resolution T-1 maps were obtained from the CS-MP2RAGE. T-1 times of white and gray matters and several deep gray nuclei are consistent with the literature and show very low variability (<1%). Conclusions The CS-MP2RAGE can be used in future protocols to rapidly obtain morphological images and quantitative T-1 maps in 3-dimensions while maintaining high repeatability in volumetry and relaxation times.
引用
收藏
页码:366 / 378
页数:13
相关论文
共 50 条
  • [31] 3T MP2RAGE MRI: An In-vivo, Clinically Applicable Marker Of Lesion Repair In Multiple Sclerosis
    Kolb, H.
    Morrison, M.
    Parvathaneni, P.
    Beck, E. S.
    Absinta, M.
    Nair, G.
    Cortese, I. C.
    Reich, D. S.
    MULTIPLE SCLEROSIS JOURNAL, 2020, 26 (1_SUPPL) : 81 - 81
  • [32] T1 mapping of the mouse brain following fractionated manganese administration using MP2RAGE
    Luc Driencourt
    Carola Jacqueline Romero
    Mario Lepore
    Florent Eggenschwiler
    Olivier Reynaud
    Nathalie Just
    Brain Structure and Function, 2017, 222 : 201 - 214
  • [33] Brain tissue segmentation based on MP2RAGE multi-contrast images in 7 T MRI
    Choi, Uk-Su
    Kawaguchi, Hirokazu
    Matsuoka, Yuichiro
    Kober, Tobias
    Kida, Ikuhiro
    PLOS ONE, 2019, 14 (02):
  • [34] CNR improvement of MP2RAGE from slice encoding directional acceleration
    Shin, Wanyong
    Shin, Taehoon
    Oh, Se-Hong
    Lowe, Mark J.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (06) : 779 - 784
  • [35] SNR Efficiency of Combined Bipolar Gradient Echoes: Comparison of Three-Dimensional FLASH, MPRAGE, and Multiparameter Mapping With VFA-FLASH and MP2RAGE
    Jutras, Jean-David
    Wachowicz, Keith
    Gilbert, Guillaume
    De Zanche, Nicola
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2186 - 2202
  • [36] T1 mapping of the mouse brain following fractionated manganese administration using MP2RAGE
    Driencourt, Luc
    Romero, Carola Jacqueline
    Lepore, Mario
    Eggenschwiler, Florent
    Reynaud, Olivier
    Just, Nathalie
    BRAIN STRUCTURE & FUNCTION, 2017, 222 (01): : 201 - 214
  • [37] Fast magnetization transfer saturation imaging of the brain using MP2RAGE T1 mapping
    Rowley, Christopher D.
    Nelson, Mark C.
    Campbell, Jennifer S. W.
    Leppert, Ilana R.
    Pike, G. Bruce
    Tardif, Christine L.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1540 - 1555
  • [38] MP2RAGE multispectral voxel-based morphometry in focal epilepsy
    Kotikalapudi, Raviteja
    Martin, Pascal
    Erb, Michael
    Scheffler, Klaus
    Marquetand, Justus
    Bender, Benjamin
    Focke, Niels K.
    HUMAN BRAIN MAPPING, 2019, 40 (17) : 5042 - 5055
  • [39] Partial Volume Model for Brain MRI Scan Using MP2RAGE
    Duche, Quentin
    Saint-Jalmes, Herve
    Acosta, Oscar
    Raniga, Parnesh
    Bourgeat, Pierrick
    Dore, Vincent
    Egan, Gary F.
    Salvado, Olivier
    HUMAN BRAIN MAPPING, 2017, 38 (10) : 5115 - 5127
  • [40] Assessment of brain volumes obtained from MP-RAGE and MP2RAGE images, quantified using different segmentation methods
    Alonso, Juli
    Pareto, Deborah
    Alberich, Manel
    Kober, Tobias
    Marechal, Benedicte
    Llado, Xavier
    Rovira, Alex
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (06) : 757 - 767