The Compressed Sensing MP2RAGE as a Surrogate to the MPRAGE for Neuroimaging at 3 T

被引:8
|
作者
Trotier, Aurelien J. [1 ]
Dilharreguy, Bixente [2 ]
Anandra, Serge [2 ]
Corbin, Nadege [1 ,3 ]
Lefrancois, William [1 ]
Ozenne, Valery [1 ]
Miraux, Sylvain [1 ]
Ribot, Emeline J. [1 ]
机构
[1] Univ Bordeaux, Ctr Resonance Magnet Syst Biol, UMR5536, CNRS, Bordeaux, France
[2] Univ Bordeaux, UMS3767, Biomed Imaging Facil pIBIO, CNRS, Bordeaux, France
[3] UCL, Wellcome Ctr Human Neumimaging, UCL Queen Sq Inst Neurol, London, England
关键词
MP2RAGE; compressed sensing; MPRAGE; volumetry; T-1; mapping; repeatability; NMR RELAXATION-TIMES; MULTIPLE-SCLEROSIS; HUMAN BRAIN; LONGITUDINAL RELAXATION; SPOILED FLASH; MRI; T-1; GRAY; R1;
D O I
10.1097/RLI.0000000000000849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) sequence provides quantitative T-1 maps in addition to high-contrast morphological images. Advanced acceleration techniques such as compressed sensing (CS) allow its acquisition time to be compatible with clinical applications. To consider its routine use in future neuroimaging protocols, the repeatability of the segmented brain structures was evaluated and compared with the standard morphological sequence (magnetization-prepared rapid gradient echo [MPRAGE]). The repeatability of the T-1 measurements was also assessed. Materials and Methods Thirteen healthy volunteers were scanned either 3 or 4 times at several days of interval, on a 3 T clinical scanner, with the 2 sequences (CS-MP2RAGE and MPRAGE), set with the same spatial resolution (0.8-mm isotropic) and scan duration (6 minutes 21 seconds). The reconstruction time of the CS-MP2RAGE outputs (including the 2 echo images, the MP2RAGE image, and the T-1 map) was 3 minutes 33 seconds, using an open-source in-house algorithm implemented in the Gadgetron framework. Both precision and variability of volume measurements obtained from CAT12 and VolBrain were assessed. The T-1 accuracy and repeatability were measured on phantoms and on humans and were compared with literature. Volumes obtained from the CS-MP2RAGE and the MPRAGE images were compared using Student t tests (P < 0.05 was considered significant). Results The CS-MP2RAGE acquisition provided morphological images of the same quality and higher contrasts than the standard MPRAGE images. Similar intravolunteer variabilities were obtained with the CS-MP2RAGE and the MPRAGE segmentations. In addition, high-resolution T-1 maps were obtained from the CS-MP2RAGE. T-1 times of white and gray matters and several deep gray nuclei are consistent with the literature and show very low variability (<1%). Conclusions The CS-MP2RAGE can be used in future protocols to rapidly obtain morphological images and quantitative T-1 maps in 3-dimensions while maintaining high repeatability in volumetry and relaxation times.
引用
收藏
页码:366 / 378
页数:13
相关论文
共 50 条
  • [1] Compressed sensing (CS) MP2RAGE versus standard MPRAGE: A of derived brain volume measurements
    Ferraro, Pilar Maria
    Gualco, Lorenzo
    Costagli, Mauro
    Schiavi, Simona
    Ponzano, Marta
    Signori, Alessio
    Massa, Federico
    Pardini, Matteo
    Castellan, Lucio
    Levrero, Fabrizio
    Zaca, Domenico
    Piredda, Gian Franco
    Hilbert, Tom
    Kober, Tobias
    Roccatagliata, Luca
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 103 : 166 - 174
  • [2] Comparison of structural T1-weighted sequences: MPRAGE to MP2RAGE
    Pareto, D.
    Alonso, J.
    Alberich, M.
    Rio, J.
    Llado, X.
    Rovira, A.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 511 - 512
  • [3] MP2RAGE for deep gray matter measurement of the brain: A comparative study with MPRAGE
    Okubo, Gosuke
    Okada, Tomohisa
    Yamamoto, Akira
    Kanagaki, Mitsunori
    Fushimi, Yasutaka
    Okada, Tsutomu
    Murata, Katsutoshi
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 55 - 62
  • [4] Accelerated MP2RAGE imaging using Cartesian phyllotaxis readout and compressed sensing reconstruction
    Mussard, Emilie
    Hilbert, Tom
    Forman, Christoph
    Meuli, Reto
    Thiran, Jean-Philippe
    Kober, Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 1881 - 1894
  • [5] Compressed-Sensing MP2RAGE sequence: Application to the detection of brain metastases in mice at 7T
    Trotier, Aurelien J.
    Rapacchi, Stanislas
    Faller, Thibaut L.
    Miraux, Sylvain
    Ribot, Emeline J.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 551 - 559
  • [6] Can 7T MPRAGE match MP2RAGE for gray-white matter contrast?
    Oliveira, Icaro A. F.
    Roos, Thomas
    Dumoulin, Serge O.
    Siero, Jeroen C. W.
    Van der Zwaag, Wietske
    NEUROIMAGE, 2021, 240
  • [7] Fully automated detection of focal cortical dysplasia: Comparison of MPRAGE and MP2RAGE sequences
    Demerath, Theo
    Kaller, Christoph P.
    Heers, Marcel
    Staack, Anke
    Schwarzwald, Ralf
    Kober, Tobias
    Reisert, Marco
    Schulze-Bonhage, Andreas
    Huppertz, Hans-Juergen
    Urbach, Horst
    EPILEPSIA, 2022, 63 (01) : 75 - 85
  • [8] MP2RAGE vs. MPRAGE surface-based morphometry in focal epilepsy
    Kronlage, Cornelius
    Heide, Ev-Christin
    Hagberg, Gisela E.
    Bender, Benjamin
    Scheffler, Klaus
    Martin, Pascal
    Focke, Niels
    PLOS ONE, 2024, 19 (02):
  • [9] Quantitative comparison of cortical surface reconstructions from MP2RAGE and multi-echo MPRAGE data at 3 and 7 T
    Fujimoto, Kyoko
    Polimeni, Jonathan R.
    van der Kouwe, Andre J. W.
    Reuter, Martin
    Kober, Tobias
    Benner, Thomas
    Fischl, Bruce
    Wald, Lawrence L.
    NEUROIMAGE, 2014, 90 : 60 - 73
  • [10] Quantitative comparison of brain volume measures as determined from MP2RAGE and MPRAGE images
    Pareto, D.
    Alonso, J.
    Alberich, M.
    Kober, T.
    Marechal, B.
    Llado, X.
    Rovira, A.