Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of flow pattern

被引:15
|
作者
Mouloudi, E [1 ]
Prinianakis, G [1 ]
Kondili, E [1 ]
Georgopoulos, D [1 ]
机构
[1] Univ Crete, Univ Hosp Herakl, Intens Care Unit, Heraklion 71110, Greece
关键词
inspiratory resistance; respiratory system mechanics; salbutamol;
D O I
10.1034/j.1399-3003.2000.16b13.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
In mechanically ventilated patients the flow pattern during bronchodilator delivery by metered-dose inhaler (MDI) could be a factor that might influence the effectiveness of this therapy, In order to test this the effect of two different inspiratory flow patterns on the bronchodilation induced by beta(2)-agonists administered via MDI and spacer in a group of mechanically ventilated patients with chronic obstructive pulmonary disease (COPD) was examined, Eighteen mechanically ventilated patients with COPD, were prospectively randomized to receive two (n=8, protocol A) or sis (n=10 protocol B) puffs salbutamol (100 mu g . puff(-1)) either under pressure control (decelerating flow pattern) or under volume control (square wave flow pattern), With both modes, tidal volume and inspiratory time were identical. Salbutamol was administered via an MDI adapted to the inspiratory limb of the ventilator circuit using an aerosol cloud-enhancer spacer. After a 6-h washout, patients were crossed over to receive the same dose of salbutamol (200 or 600 mu g, respectively in protocols A and B) by the alternative mode of administration. Static and dynamic airway pressures, minimum (Rint) and maximum (Rrs) inspiratory resistance and the difference between Rrs and Rint (Delta R) were measured before and at 15, 30 and 60 min after salbutamol, Independent of the dose, salbutamol caused a significant decrease in dynamic and static airway pressures, Rint and Rrs, These changes were not influenced by the inspiratory flow pattern and were evident at 15, 30 and 60 min after salbutamol, It is concluded that salbutamol delivered via metered dose inhaler and spacer device, induces significant bronchodilation in mechanically ventilated patients with chronic obstructive pulmonary disease, the magnitude of which is not affected by the inspiratory flow/time profile.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [31] Metered-Dose Inhaler Compared To Nebulizer For Bronchodilator Treatment Of Inpatients With Asthma Exacerbation
    Pajor, N. M.
    Nevin, M. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [32] COMPARISON OF BRONCHODILATOR EFFECTS OF METERED-DOSE INHALER AND NEBULIZER TREATMENTS WITH BITOLTEROL MESYLATE
    BHATT, BD
    CHEN, TM
    NEIDL, MJ
    PINNAS, JL
    ANNALS OF ALLERGY, 1985, 55 (02): : 396 - 396
  • [33] OROPHARYNGEAL DEPOSITION AND DELIVERY ASPECTS OF METERED-DOSE INHALER AEROSOLS
    GONDA, I
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (04): : 985 - 986
  • [34] Delivery of Epinephrine by Metered-Dose Inhaler for the Treatment of Croup in Children
    Kahne, K.
    Krief, W.
    Victoria, P.
    Dumont, O.
    ANNALS OF EMERGENCY MEDICINE, 2022, 80 (04) : S111 - S111
  • [35] OROPHARYNGEAL DEPOSITION AND DELIVERY ASPECTS OF METERED-DOSE INHALER AEROSOLS
    KIM, CS
    ELDRIDGE, MA
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 135 (01): : 157 - 164
  • [36] Selecting an accessory device with a metered-dose inhaler: Variable influence of accessory devices on fine particle dose, throat deposition, and drug delivery with asynchronous actuation from a metered-dose inhaler
    Wilkes, W
    Fink, J
    Dhand, R
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (03): : 351 - 360
  • [37] COMPARISON OF THE BRONCHODILATOR RESPONSE TO ALBUTEROL ADMINISTERED BY THE OPTIHALER, THE AEROCHAMBER, OR BY METERED-DOSE INHALER ALONE
    NELSON, HS
    LOFFERT, DT
    ANNALS OF ALLERGY, 1994, 72 (04): : 337 - 340
  • [38] Nebulization versus metered-dose inhaler and spacer in bronchodilator responsiveness testing: a retrospective study
    Lu, Rongli
    Li, Ying
    Hu, Chengping
    Pan, Pinhua
    Zhao, Qiaohong
    He, Ruoxi
    THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2023, 17
  • [39] A novel method of metered-dose inhaler delivery in intubated COVID-19 patients
    Mustahsin, Mohd.
    Singh, Garima
    Choubey, Sanjay
    SAUDI JOURNAL OF ANAESTHESIA, 2022, 16 (01) : 127 - +
  • [40] BRONCHODILATOR REVERSIBILITY AND ONSET WITH BUDESONID/FORMOTEROL PRESSURIZED METERED-DOSE INHALER (BUD/FM PMDI) IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE (COPD)
    Celli, B. R.
    Tashkin, D. P.
    Rennard, S. I.
    McElhattan, J.
    Martin, U. J.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2009, 103 (05) : A61 - A61