Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico

被引:109
|
作者
Báez, A [1 ]
Padilla, H [1 ]
García, R [1 ]
Torres, MD [1 ]
Rosas, I [1 ]
Belmont, R [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Lab Quim Atmosfer, Ctr Ciencias Atmosfera, Mexico City 04510, DF, Mexico
关键词
indoor; aldehydes pollution; carbonyls; exposure; risk;
D O I
10.1016/S0048-9697(02)00344-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Carbonyl compounds in air were measured at two houses, three museums, and two offices. All sites lacked air-conditioning systems. Although indoor and outdoor air was measured simultaneously at each site, the sites themselves were sampled in different dates. Mean concentrations were higher in indoor air. Outdoor means concentrations of acetone were the highest in all sites, ranging from 12 to 60 mug m(-3). In general, formaldehyde and acetaldehyde had similar mean concentrations, ranging from 4 to 32 and 6 to 28 mug m(-3), respectively. Formaldehyde and acetone mean indoor concentrations were the highest, ranging from 11 to 97 and 17 to 89 mug m(-3), respectively, followed by acetaldehyde with 5 to 47 mug m(-3). Formaldehyde and acetaldehyde had the highest mean concentration in the offices where there were smokers. Propionaldehyde and butyraldehyde concentrations did not show definite differences between indoor and outdoor air. In general, the highest outdoor and indoor hourly concentrations were observed from 10:00 to 15:00 h. Mean indoor/outdoor ratios of carbonyls exceeded 1. Formaldehyde and acetaldehyde risks were higher in smoking environments. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 226
页数:16
相关论文
共 50 条
  • [41] Air pollution and respiratory health in Mexico city
    HernandezGarduno, E
    PerezNeria, J
    Paccagnella, AM
    PinaGarcia, MA
    MunguiaCastro, M
    CatalanVazquez, M
    RojasRamos, M
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1997, 39 (04) : 299 - 307
  • [42] STUDY LOOKS AT MEXICO-CITY AIR
    不详
    GEOTIMES, 1992, 37 (03): : 9 - 10
  • [43] The nature of air pollution dynamics in Mexico City
    Raga, GB
    LeMoyne, L
    NINTH JOINT CONFERENCE ON APPLICATIONS OF AIR POLLUTION METEOROLOGY WITH A&WMA, 1996, : 384 - 385
  • [44] Air pollution and infant mortality in Mexico City
    Loomis, D
    Castillejos, M
    Gold, DR
    McDonnell, W
    Borja-Aburto, VH
    EPIDEMIOLOGY, 1999, 10 (02) : 118 - 123
  • [45] Air pollution and unleaded gasoline in Mexico City
    Hanna, Brid Gleeson
    Garcia, Alethia Jimenez
    ECONOMICS BULLETIN, 2008, 18
  • [46] AIR-QUALITY IN MEXICO-CITY
    GARFIAS, J
    GONZALEZ, R
    ACS SYMPOSIUM SERIES, 1992, 483 : 149 - 161
  • [47] Personal exposure to elements in Mexico City air
    RiverosRosas, H
    Pfeifer, GD
    Lynam, DR
    Pedroza, JL
    JulianSanchez, A
    Canales, O
    Garfias, J
    SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 198 (01) : 79 - 96
  • [48] Blood lead level in schoolchildren and airborne lead levels in Mexico City, Mexico
    Meneses-Gonzalez, F.
    Baltazar-Reyes, M. C.
    Hernandez-Avila, M.
    Avila-Medina, S. L.
    EPIDEMIOLOGY, 2006, 17 (06) : S398 - S398
  • [49] The tallest building in Mexico City - Torre Mayor Mexico City, Mexico
    Rahimian, A
    Romero, EM
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1999, : 755 - 773
  • [50] INDOOR AND OUTDOOR AIR MEASUREMENTS AT A CITY STREET WITH HEAVY TRAFFIC
    MULLER, J
    STAUB REINHALTUNG DER LUFT, 1991, 51 (04): : 147 - 154