Tracking Personal Health-Environment Interaction with Novel Mobile Sensing Devices

被引:5
|
作者
Deng, Yue [1 ,2 ]
Liu, Nai-Yuan [1 ,2 ]
Tsow, Francis [2 ]
Xian, Xiaojun [2 ]
Krajmalnik-Brown, Rosa [3 ,4 ]
Tao, Nongjian [2 ]
Forzani, Erica [1 ,2 ]
机构
[1] Arizona State Univ, Sch Engn Matter Transport & Energy, Tempe, AZ 85287 USA
[2] Arizona State Univ, Biodesign Inst, Ctr Bioelect & Biosensors, Tempe, AZ 85287 USA
[3] Arizona State Univ, Biodesign Inst, Swette Ctr Environm Biotechnol, Tempe, AZ 85287 USA
[4] Arizona State Univ, Sch Sustainable Engn & Built Environm, Tempe, AZ 85287 USA
关键词
volatile organic compounds (VOCs); resting metabolic rate (RMR); mobile sensors; environmental exposure; RESTING METABOLIC-RATE; VOLATILE ORGANIC-COMPOUNDS; WEIGHT-LOSS; THYROID-HORMONE; ASSOCIATION; SENSOR; ADULTS;
D O I
10.3390/s18082670
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of connected health devices has allowed for a more accurate assessment of a person's state under free-living conditions. In this work, we use two mobile sensing devices and investigate the correlation between individual's resting metabolic rate (RMR) and volatile organic compounds (VOCs) exposure levels. A total of 17 healthy, young, and sedentary office workers were recruited, measured for RMR with a mobile indirect calorimetry (IC) device, and compared with their corresponding predicted RMR values from the Academy of Nutrition and Dietetics' recommended epidemiological equation, the Mifflin-St Jeor equation (MSJE). Individual differences in the RMR values from the IC device and the epidemiological equation were found, and the subjects' RMRs were classified as normal, high, or low based on a cut-off of +/- 200 kcal/day difference with respect to the predicted value. To study the cause of the difference, VOCs exposure levels of each participant's daytime working environment and nighttime resting environment were assessed using a second mobile sensing device for VOCs exposure detection. The results showed that all sedentary office workers had a low VOCs exposure level (<2 ppmC), and there was no obvious correlation between VOCs exposure and the RMR difference. However, an additional participant who was a worker in an auto repair shop, showed high VOCs exposure with respect to the sedentary office worker population and a significant difference between measured and predicted RMR, with a low RMR of 500 kcal/day difference. The mobile sensing devices have been demonstrated to be suitable for the assessment of direct information of human health-environment interactions at free-living conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] CAMERA-BASED GESTURE TRACKING FOR 3D INTERACTION BEHIND MOBILE DEVICES
    Yousefi, Shahrouz
    Kondori, Farid Abedan
    Li, Haibo
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2012, 26 (08)
  • [32] Mobile Devices Applied to Computer Science Subjects to Consume Institutional Functionalities Through a Personal Learning Environment
    Conde, Miguel A.
    Penalvo, Francisco G.
    Alier, Marc
    Casany, Maria J.
    Piguillem, Jordi
    INTERNATIONAL JOURNAL OF ENGINEERING EDUCATION, 2013, 29 (03) : 610 - 619
  • [33] Ethical implications of location and accelerometer measurement in health research studies with mobile sensing devices
    Fuller, Daniel
    Shareck, Martine
    Stanley, Kevin
    SOCIAL SCIENCE & MEDICINE, 2017, 191 : 84 - 88
  • [34] A Multi-Technique Reconfigurable Electrochemical Biosensor: Enabling Personal Health Monitoring in Mobile Devices
    Sun, Alexander
    Venkatesh, A. G.
    Hall, Drew A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (05) : 945 - 954
  • [35] KITE: Platform for Mobile Augmented Reality Gaming and Interaction Using Magnetic Tracking and Depth Sensing
    Piumsomboon, Thammathip
    Clark, Adrian
    Billinghurst, Mark
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY (ISMAR) - SCIENCE AND TECHNOLOGY, 2013, : 289 - 290
  • [36] Human-computer interaction in an integrated environment combining digital TV, mobile devices and internet
    Punt, Marija M.
    2016 24TH TELECOMMUNICATIONS FORUM (TELFOR), 2016, : 845 - 852
  • [37] Securing personal health information access in mobile healthcare environment through short signature schemes
    School of IT and Computer Science, University of Wollongong, Northfields Avenue, NSW 2522, Australia
    Int. J. Mobile Commun., 2007, 2 (215-224):
  • [38] A Novel Interaction Method for Mobile Devices Using Low Complexity Global Motion Estimation
    Toan Dinh Nguyen
    Kim, JeongHwan
    Kim, SooHyung
    Yang, HyungJeong
    Lee, GueeSang
    Chang, JuneYoung
    Eum, NakWoong
    ETRI JOURNAL, 2012, 34 (05) : 734 - 742
  • [39] Integrating Wireless Sensor Networks with CE Devices for Health Care Activity Tracking in the Home Environment
    Bosman, Remi
    Lukkien, Johan
    Verhoeven, Richard
    2009 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, 2009, : 87 - 88
  • [40] A novel interaction metaphor for personal environment control: direct manipulation of physical environment based on 3D visualization
    Shirehjini, AAN
    COMPUTERS & GRAPHICS-UK, 2004, 28 (05): : 667 - 675