Real-time Visualization of Altered Gastric Motility by Magnetic Resonance Imaging in Patients with Parkinson's Disease

被引:34
|
作者
Unger, Marcus M. [1 ]
Hattemer, Katja [1 ]
Moeller, Jens C. [1 ]
Schmittinger, Katrin [1 ]
Mankel, Katharina [1 ]
Eggert, Karla [1 ]
Strauch, Konstantin [2 ]
Tebbe, Johannes J. [3 ,4 ]
Keil, Boris [5 ]
Oertel, Wolfgang H. [1 ]
Heverhagen, Johannes T. [5 ]
Knake, Susanne [1 ]
机构
[1] Univ Marburg, Dept Neurol, D-35033 Marburg, Germany
[2] Univ Marburg, Inst Med Biometry & Epidemiol, D-35033 Marburg, Germany
[3] Klinikum Lippe, Dept Internal Med, Div Gastroenterol, Detmold, Germany
[4] Univ Marburg, Dept Internal Med, Div Gastroenterol & Endocrinol, D-3550 Marburg, Germany
[5] Univ Marburg, Dept Diagnost Radiol, D-35033 Marburg, Germany
关键词
Parkinson's disease; nonmotor symptoms; gastric motility; real-time magnetic resonance imaging; autonomic nervous system; enteric nervous system; ENTERIC NERVOUS-SYSTEM; BRAIN PATHOLOGY; LEWY BODIES; PLEXUSES; MEAL;
D O I
10.1002/mds.22841
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Gastrointestinal motility is frequently affected in Parkinson's disease (PD) and has even been reported in early stages of PD. We hypothesized that gastric motility can be assessed in vivo by real-time magnetic resonance imaging (MRI), an established, noninvasive method. After an overnight fast and A standardized test meal, 10 patients with PD (six drug naive, four treated) and 10 healthy volunteers underwent real-time MRI scanning of the stomach. Gastric motility was quantified by calculating the gastric motility indices (GMI) from transversal oblique und sagittal oblique MRI scans. There was a trend toward a decreased gastric motility in patients with PD compared with healthy controls (Mann-Whitney test, P 0.059). This difference in peristalsis was due to a significant reduction in the amplitude of peristaltic contractions (P 0.029) and not to a decelerated velocity of the peristaltic waves (P 0.97). Real-time MRI allows direct visualization of gastric motility in PD. In this pilot study, a relatively high interindividual variability impaired accurate separation of our PD sample from healthy controls. The trend toward decreased gastric motility is in accordance with previous studies that investigated gastric motility in patients with PD using other methods. Our study provides first demonstration of a possible underlying mechanism for disturbed gastric motility in PD (reduced amplitude of contractions versus altered velocity of peristaltic waves). Further studies in drug-naive PD patients are required to determine the discriminatory power and validity of this technique in PD. (C) 2010 Movement Disorder Society
引用
收藏
页码:623 / 628
页数:6
相关论文
共 50 条
  • [41] Real-time functional magnetic resonance imaging: methods and applications
    Weiskopf, Nikolaus
    Sitaram, Ranganatha
    Josephs, Oliver
    Veit, Ralf
    Scharnowski, Frank
    Goebel, Rainer
    Birbaumer, Niels
    Deichmann, Ralf
    Mathiak, Klaus
    MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 989 - 1003
  • [42] In vitro real-time magnetic resonance imaging for quantification of thrombosis
    Ling Yang
    Thomas Neuberger
    Keefe B. Manning
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 285 - 295
  • [43] Hyperpolarised magnetic resonance for in vivo real-time metabolic imaging
    Apps, Andrew
    Lau, Justin
    Peterzan, Mark
    Neubauer, Stefan
    Tyler, Damian
    Rider, Oliver
    HEART, 2018, 104 (18) : 1484 - +
  • [44] In vitro real-time magnetic resonance imaging for quantification of thrombosis
    Yang, Ling
    Neuberger, Thomas
    Manning, Keefe B.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (02) : 285 - 295
  • [45] An approach to real-time magnetic resonance imaging for speech production
    Narayanan, S
    Nayak, K
    Lee, SB
    Byrd, D
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (04): : 1771 - 1776
  • [46] Real-Time Magnetic Resonance Imaging: Diagnostic and Interventional Applications
    Albert C. Lardo
    Pediatric Cardiology, 2000, 21 : 80 - 98
  • [47] Real-time magnetic resonance imaging of fluidized beds with internals
    Penn, Alexander
    Boyce, Christopher M.
    Conzelmann, Nicholas
    Bezinge, Gaetan
    Pruessmann, Klaas P.
    Muller, Christoph R.
    CHEMICAL ENGINEERING SCIENCE, 2019, 198 : 117 - 123
  • [48] Real-time magnetic resonance imaging: Diagnostic and interventional applications
    Lardo, AC
    PEDIATRIC CARDIOLOGY, 2000, 21 (01) : 80 - 98
  • [49] Real-Time Magnetic Resonance Imaging Guidance for Cardiovascular Procedures
    Horvath, Keith A.
    Li, Ming
    Mazilu, Dumitru
    Guttman, Michael A.
    McVeigh, Elliot R.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2007, 19 (04) : 330 - 335
  • [50] Gastric motility measurement by magnetic resonance imaging and ultrasonography
    Urushihara, T
    Shimokado, K
    Kuroda, Y
    Kuranishi, F
    Onoe, T
    Ishiyama, K
    Hashizume, J
    Shishida, M
    7TH WORLD CONGRESS OF ENDOSCOPIC SURGERY, 2000, : 851 - 855