Relative viscosity evaluation of low-volume samples using capillary flow under differential pressure

被引:2
|
作者
Sakamoto, Kenji [1 ]
Okazaki, Nobumitsu [2 ]
Makino, Koji [2 ]
Osawa, Yukihiro [3 ]
Sanari, Nobuyuki [3 ]
Hachiya, Yuriko [4 ]
Ohno, Koki [5 ]
机构
[1] Kyusyu Inst Technol, Dept Intelligent & Control Syst, 680-4 Kawazu, Iizuka, Fukuoka 8208502, Japan
[2] Uchiyama Mfg Corp, Naka Ku, 2-1-10 Kobashi Chou, Okayama, Okayama 7038588, Japan
[3] Sibata Sci Technol Ltd, 1-1-62 Nakane, Soka, Saitama 3400005, Japan
[4] Univ Occupat & Environm Hlth, Sch Hlth Sci, Occupat & Community Hlth Nursing, Yahatanishi Ku, 1-1 Iseigaoka, Kitakyushu, Fukuoka 8078555, Japan
[5] Univ Occupat & Environm Hlth, Sch Med, Yahatanishi Ku, 1-1 Iseigaoka, Kitakyushu, Fukuoka 8078555, Japan
关键词
biosensing; viscosity; surface tension; capillary; microfluidics; BLOOD-VISCOSITY; LIQUIDS; SALIVA; MUCIN;
D O I
10.35848/1347-4065/ac6d94
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this study, we newly considered the analysis of capillary flow under differential pressure, which extends the previous study and allows the independent measurement of relative viscosity and the product of relative surface tension and contact angle for low-volume samples. The theory of this method is explained, and it is demonstrated that relative viscosity and surface tension with contact angle can be obtained independently by measuring the capillary flow under differential pressure. We conducted capillary flow experiments with a small sample volume (less than 100 mu l) using a measurement system comprising a flow measurement unit, capillary chip, and differential pressure mechanism. The relative viscosities of pure water and dilute ethanol solutions obtained in the experiment were in one-to-one correspondence with the values in the Chemical Handbook. This also shows that relative surface tension can be determined using these measurement results and the separately measured contact angle values.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Evaluation of different types of soil subgrade using glass powder for Low-Volume Roads (LVRs)
    Harinder, D.
    Chandu, B.
    Aditya, M.
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 4487 - 4491
  • [12] Analysis of citrate in low-volume seminal fluid samples using a time-gated measurement of europium luminescence
    Pal, Robert
    Beeby, Andrew
    Parker, David
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (02) : 352 - 358
  • [13] Evaluation of Accessible Porosity Using Mercury Injection Capillary Pressure Data in Shale Samples
    Davudov, Davud
    Moghanloo, Rouzbeh Ghanbarnezhad
    Lan, Yuzheng
    ENERGY & FUELS, 2018, 32 (04) : 4682 - 4694
  • [14] UNSTEADY AERODYNAMICS OF LOW-PRESSURE STEAM TURBINES OPERATING UNDER LOW VOLUME FLOW
    Megerle, Benjamin
    Rice, Timothy Stephen
    McBean, Ivan
    Ott, Peter
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 5B, 2013,
  • [15] Unsteady Aerodynamics of Low-Pressure Steam Turbines Operating Under Low Volume Flow
    Megerle, Benjamin
    McBean, Ivan
    Rice, Timothy Stephen
    Ott, Peter
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2014, 136 (09):
  • [16] Light Weight Deflectometer Evaluation of Low-Volume Road Structural Deterioration under Rapidly Increased Traffic Patterns
    Ordaz, Margarita
    Doyle, Jesse D.
    Howard, Isaac L.
    TRANSPORTATION RESEARCH RECORD, 2024, 2678 (04) : 948 - 966
  • [17] Simultaneous measurement of cyclosporin A and creatinine concentrations in low-volume capillary blood (finger-prick) samples using liquid chromatography electrospray-ionisation tandem mass spectrometry
    Cooper, D
    Keevil, BG
    Tierney, DP
    Morris, MR
    CLINICAL CHEMISTRY, 2002, 48 (06) : A53 - A53
  • [18] Ultrasensitive Sensor Using Quantum Dots-Doped Polystyrene Nanospheres for Clinical Diagnostics of Low-Volume Serum Samples
    Chen, Zhenhua
    Li, Peng
    Zhang, Zhigao
    Zhai, Xiangming
    Liang, Junyu
    Chen, Qiong
    Li, Kun
    Lin, Guanfeng
    Liu, Tiancai
    Wu, Yingsong
    ANALYTICAL CHEMISTRY, 2019, 91 (09) : 5777 - 5785
  • [19] Experimental Evaluation of an Intravascular Differential Pressure Flow Meter using MEMS Pressure Sensors
    Satyamurthy, Kumar Swamy Hosur
    Timpson, Erik
    Leon-Salas, Walter Daniel
    2011 IEEE SENSORS, 2011, : 1161 - 1164
  • [20] Cost-effective low-volume sample introduction system for open tubular capillary ion chromatography via a hybrid negative pressure approach
    Harnmontree, Watcharapoln
    Somboot, Wasin
    Kawichai, Sawaeng
    Jakmunee, Jaroon
    Kanyanee, Tinakorn
    TALANTA, 2025, 284