Light and viscosity effects on the curing potential of bulk-fill composites placed in deep cavities

被引:5
|
作者
Modena, Rodrigo Antonio [1 ]
Coelho Sinhoreti, Mario Alexandre [2 ]
Palin, William [3 ]
Cavalcante, Larissa Maria [1 ]
Schneider, Luis Felipe [1 ,4 ]
机构
[1] UFF Univ Fed Fluminense, Sch Dent, Niteroi, RJ, Brazil
[2] Univ Estadual Campinas, UNICAMP, Piracicaba Sch Dent, Dept Restorat Dent,Dent Mat Div, Piracicaba, SP, Brazil
[3] Univ Birmingham, Coll Med & Dent Sci, Sch Dent, Inst Clin Sci,Biomat Unit, Birmingham, W Midlands, England
[4] Univ Veiga de Almeida, Nucleus Dent Biomat Res, Praca Bandeira 149, Rio De Janeiro, RJ, Brazil
关键词
Bulk-fill; Composite; Depth of cure; Light curing units; Polymerization; Viscosity; POLYMERIZATION SHRINKAGE; COLOR STABILITY; CONVERSION; DEPTH; CURE; MICROHARDNESS; KINETICS; STRESS; TIME;
D O I
10.1007/s10266-021-00614-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To determine the influence of light curing units (LCUs) and material viscosity on the degree of conversion (DC) of bulk-fill (BF) resin-based composites (RBCs) placed in deep cavity preparations. Four LCUs were tested: Valo cordless, Bluephase-G2, Poly wireless and Radii-cal. Light irradiance was determined at 0 mm and 6 mm distance to the reading sensor. The following RBCs were considered: Filtek BF, Filtek BF Flow, Opus BF, Opus BF Flow, Tetric N-Ceram BF and Surefil SDR Flow. Sirius-Z was used with the incremental technique. DC (n = 3) was evaluated by spectroscopy both at top and bottom regions of deep preparations with 6 mm depth. The data were submitted to ANOVA and Tukey's test (alpha = 0.05). Pearson's correlation (95%) was used to verify the relation between the LCUs and the curing potential of RBCs. The DC at 6 mm depth was reduced when Opus BF, Opus BF Flow and Tetric N-Ceram BF were activated with Radii-cal. There was a positive correlation between the LCU irradiance and the bottom/top conversion ratios. The materials' viscosities did not affect the curing potential. Bulk-fill composites did not present higher curing potential than the conventional composite used with the incremental technique; the most important aspect of the LCU was the irradiance ratio; and the materials' viscosity did not affect the curing potential as a function of depth. Radii-cal negatively impacted the degree of conversion at 6 mm depth for most bulk-fill resin composites. Depending on the brand, bulk-fill composites may present reduced curing potential due to the light source when placed in deep cavities. Dentists should avoid LCU with acrylic tips to photoactivate bulk-fill resin-based composites.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [1] Light and viscosity effects on the curing potential of bulk-fill composites placed in deep cavities
    Rodrigo Antonio Modena
    Mário Alexandre Coelho Sinhoreti
    William Palin
    Larissa Maria Cavalcante
    Luis Felipe Schneider
    [J]. Odontology, 2021, 109 : 874 - 883
  • [2] Curing behaviour of high-viscosity bulk-fill composites
    Ilie, Nicoleta
    Stark, Katharina
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (08) : 977 - 985
  • [3] Bulk-fill resin composites: Polymerization properties and extended light curing
    Zorzin, Jose
    Maier, Eva
    Harre, Sarah
    Fey, Tobias
    Belli, Renan
    Lohbauer, Ulrich
    Petschelt, Anselm
    Taschner, Michael
    [J]. DENTAL MATERIALS, 2015, 31 (03) : 293 - 301
  • [4] Internal and marginal adaptation of high-viscosity bulk-fill composites in class II cavities placed with different adhesive strategies
    Haak, Rainer
    Naeke, Thomas
    Park, Kyung-Jin
    Ziebolz, Dirk
    Krause, Felix
    Schneider, Hartmut
    [J]. ODONTOLOGY, 2019, 107 (03) : 374 - 382
  • [5] Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity
    Nicoleta Ilie
    [J]. Clinical Oral Investigations, 2019, 23 : 747 - 755
  • [6] Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) : 747 - 755
  • [7] Curing characteristics of flowable and sculptable bulk-fill composites
    Miletic, Vesna
    Pongprueksa, Pong
    De Munck, Jan
    Brooks, Neil R.
    Van Meerbeek, Bart
    [J]. CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1201 - 1212
  • [8] Curing characteristics of flowable and sculptable bulk-fill composites
    Vesna Miletic
    Pong Pongprueksa
    Jan De Munck
    Neil R. Brooks
    Bart Van Meerbeek
    [J]. Clinical Oral Investigations, 2017, 21 : 1201 - 1212
  • [9] Effect of Shortened Light-Curing Modes on Bulk-Fill Resin Composites
    Sampaio, C. S.
    Pizarro, P. G.
    Atria, P. J.
    Hirata, R.
    Giannini, M.
    Mahn, E.
    [J]. OPERATIVE DENTISTRY, 2020, 45 (05) : 496 - 505
  • [10] INFLUENCE OF BULK THICKNESS, CURING TIME, AND CURING UNIT TYPE ON THE MICROHARDNESS OF DIFFERENT-VISCOSITY BULK-FILL COMPOSITES
    Saipullaev, M.
    Erdemir, U.
    Yildiz, E.
    [J]. MECHANICS OF COMPOSITE MATERIALS, 2018, 54 (05) : 675 - 684