Changes in Optical Properties During Heating of ex vivo Liver Tissues

被引:1
|
作者
Nagarajan, Vivek Krishna [1 ]
Gogineni, Venkateswara R. [2 ]
White, Sarah B. [2 ]
Yu, Bing [3 ]
机构
[1] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
[2] Med Coll Wisconsin, Dept Radiol, Wauwatosa, WI USA
[3] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
关键词
Thermal ablation; tissue damage monitoring; optical properties; diffuse reflectance spectra (DRS); RENAL-CELL CARCINOMA; PERCUTANEOUS RADIOFREQUENCY ABLATION; SMALL HEPATOCELLULAR-CARCINOMA; LONG-TERM-SURVIVAL; THERMAL THERAPY; LASER-ABLATION; INTERSTITIAL THERMOTHERAPY; MICROWAVE ABLATION; LUNG-TUMORS; CANCER;
D O I
10.1117/12.2253479
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Thermal ablation is the use of heat to induce cell death through coagulative necrosis. Ideally, complete ablation of tumor cells with no damage to surrounding critical structures such as blood vessels, nerves or even organs is desired. Ablation monitoring techniques are often employed to ensure optimal tumor ablation. In thermal tissue ablation, tissue damage is known to be dependent on the temperature and time of exposure. Aptly, current methods for monitoring ablation rely profoundly on local tissue temperature and duration of heating to predict the degree of tissue damage. However, such methods do not take into account the microstructural and physiological changes in tissues as a result of thermocoagulation. Light propagation within biological tissues is known to be dependent on the tissue microstructure and physiology. During tissue denaturation, changes in tissue structure alter light propagations in tissue which could be used to directly assess the extent of thermal tissue damage. We report the use of a spectroscopic system for monitoring the tissue optical properties during heating of ex vivo liver tissues. We observed that during tissue denaturation, continuous changes in wavelength-averaged mu(a)(lambda) and mu'(s)(lambda) followed a sigmoidal trend and are correlated with damage predicted by Arrhenius model.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Dynamics of thermoelastic expansion for native and coagulated ex-vivo bovine liver tissues
    Soroushian, Behrouz
    Whelan, William M.
    Kolios, Michael C.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [42] Integrated Optical Coherence Tomography and Optical Coherence Microscopy Imaging of Ex Vivo Human Renal Tissues
    Lee, Hsiang-Chieh
    Zhou, Chao
    Cohen, David W.
    Mondelblatt, Amy E.
    Wang, Yihong
    Aguirre, Aaron D.
    Shen, Dejun
    Sheikine, Yuri
    Fujimoto, James G.
    Connolly, James L.
    JOURNAL OF UROLOGY, 2012, 187 (02): : 691 - 699
  • [43] A robust ex vivo method to evaluate the diffusion properties of agents in biological tissues
    Carneiro, Isa
    Carvalho, Sonia
    Henrique, Rui
    Oliveira, Luis M.
    Tuchin, Valery V.
    JOURNAL OF BIOPHOTONICS, 2019, 12 (04)
  • [44] Ex vivo liver resection
    Hemming, AW
    Chari, RS
    Cattral, MS
    CANADIAN JOURNAL OF SURGERY, 2000, 43 (03) : 222 - 224
  • [45] Optical properties of normal and thermally coagulated chicken liver tissue measured ex-vivo with diffuse reflectance
    M. Hafeez-Ullah
    S. Atif
    M. S. Firdous
    M. Y. Mehmood
    M. Hamza
    G. Imran
    M. Hussain
    Optics and Spectroscopy, 2011, 110 : 313 - 319
  • [46] Evaluation of the suitability of ex vivo handled ovarian tissues for optical diagnosis by Raman microspectroscopy
    Krishna, CM
    Sockalingum, GD
    Venteo, L
    Bhat, RA
    Kushtagi, P
    Pluot, M
    Manfait, M
    BIOPOLYMERS, 2005, 79 (05) : 269 - 276
  • [47] Optical properties of normal and thermally coagulated chicken liver tissue measured ex-vivo with diffuse reflectance
    Hafeez-Ullah
    Atif, M.
    Firdous, S.
    Mehmood, M. S.
    Hamza, M. Y.
    Imran, M.
    Hussain, G.
    Ikram, M.
    OPTICS AND SPECTROSCOPY, 2011, 110 (02) : 313 - 319
  • [48] MRI INDUCED HEATING IN A STENT: TRANSLATING MEASURED EX-VIVO HEATING RESULTS TO IN VIVO HEATING
    Visaria, Rachana
    Shrivastava, Devashish
    ASME 2013 CONFERENCE ON FRONTIERS IN MEDICAL DEVICES: APPLICATIONS OF COMPUTER MODELING AND SIMULATION, 2013,
  • [49] Monitoring changes in tissue optical properties following interstitial photothermal therapy of ex vivo human prostate tissue
    Weersink, Robert A.
    He, Jie
    Veilleux, Israel
    Trachtenberg, John
    Wilson, Brian C.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE X, 2013, 8578
  • [50] Therapeutics administered during ex vivo liver machine perfusion:An overview
    Julianna E Buchwald
    Jing Xu
    Adel Bozorgzadeh
    Paulo N Martins
    World Journal of Transplantation, 2020, (01) : 1 - 14