Magnetic molecularly imprinted polymer based - micro-solid phase extraction of cocaine and metabolites in plasma followed by high performance liquid chromatography - tandem mass spectrometry

被引:18
|
作者
Sanchez-Gonzalez, Juan [1 ]
Barreiro-Grille, Tania [1 ]
Cabarcos, Pamela [2 ]
Jesus Tabernero, Maria [2 ]
Bermejo-Barrera, Pilar [1 ]
Moreda-Pineiro, Antonio [1 ]
机构
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Ave Ciencias S-N, Santiago De Compostela 15782, Spain
[2] Univ Santiago de Compostela, Fac Med, Dept Pathol Anat & Forens Sci, Rua San Francisco S-N, Santiago De Compostela 15782, Spain
关键词
Magnetic molecularly imprinted polymer; Plasma; Cocaine; HPLC-MS/MS; ENVIRONMENTAL WATER SAMPLES; SELECTIVE EXTRACTION; BOVINE HEMOGLOBIN; AQUEOUS-SOLUTION; RHODAMINE-B; NANOPARTICLES; RECOGNITION; URINE; MICROEXTRACTION; ANTIBIOTICS;
D O I
10.1016/j.microc.2016.03.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel adsorbent, magnetic molecularly imprinted polymer (MMIP) based on magnetite nanoparticles surface covered with an MIP selective for cocaine (COC), was synthesised and used in batch micro-solid phase extraction (mu-SPE) for isolation of COC and metabolites (benzoylecgonine, BZE; cocaethylene, CE; and ecgonine methyl ester, EME) from plasma samples. High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was used for performing analysis. Parameters such as sample pH, magnetic stirring speed, extraction temperature and time (loading stage), composition and volume of the eluting solution, and desorption time, were optimised. Under the most favourable conditions, the highest extraction yields were obtained by using 0.1 to 1.0 mL of plasma (pH adjusted at 8.5) plus 50 mg of MMIP, and magnetic stirring (20 degrees C, 100 rpm) for 4 min. Elution was performed with 2 mL of a dichloromethane/2-propanol/ammonium hydroxide (75:20:5) mixture under ultrasound irradiation (325 W, 35 kHz) for 5 min. The limits of detection were between 0.013 and 036 ng L-1, and the limits of quantification were from 0.043 to 1.2 ng L-1. The relative standard deviations of intra- and inter-day tests (three concentration levels tested) ranged from 1 to 9% and from 2 to 10%, respectively. Analytical recoveries were in the range of 91-102% when spiking drug-free plasma samples at three concentration levels. Accurate results were also obtained after analysing a BTMF 1/11-B control material. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [41] Solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry
    Huang, Jin-Feng
    Xian, Yan-Ping
    Li, Xiu-Ying
    Cai, Wei-Hong
    Li, He
    Lin, Sen-Yu
    He, Min-Heng
    Guo, Xin-Dong
    Modern Food Science and Technology, 2014, 30 (12) : 241 - 246
  • [42] Magnetic molecularly imprinted polymers for the determination of β-agonist residues in milk by ultra high performance liquid chromatography with tandem mass spectrometry
    Liu, Hongcheng
    Lin, Xin
    Lin, Tao
    Zhang, Yulong
    Luo, Yinglan
    Li, Qiwan
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (18) : 3594 - 3601
  • [43] Simultaneous Determination of Thidiazuron and Forchlorfenuron in Orange by Solid Phase Extraction with Molecularly Imprinted Membrane Followed by High Performance Liquid Chromatography
    分子印迹膜-固相萃取-高效液相色谱法同时检测橙子中噻苯隆和氯吡脲
    Wang, Jian (wangjian595573@sohu.com), 2025, 46 (01): : 176 - 183
  • [44] Determination of Sulfonamides in Feeds by High Performance Liquid Chromatography with Molecularly Imprinted Solid Phase Extraction
    Du Bi-Bai
    Xu Yang
    Huang Yun-Hong
    Kang Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (12) : 1871 - 1876
  • [45] Trace analysis of antidepressants in environmental waters by molecularly imprinted polymer-based solid-phase extraction followed by ultra-performance liquid chromatography coupled to triple quadrupole mass spectrometry
    Demeestere, Kristof
    Petrovic, Mira
    Gros, Meritxell
    Dewulf, Jo
    Van Langenhove, Herman
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (02) : 825 - 837
  • [46] Trace analysis of antidepressants in environmental waters by molecularly imprinted polymer-based solid-phase extraction followed by ultra-performance liquid chromatography coupled to triple quadrupole mass spectrometry
    Kristof Demeestere
    Mira Petrović
    Meritxell Gros
    Jo Dewulf
    Herman Van Langenhove
    Damià Barceló
    Analytical and Bioanalytical Chemistry, 2010, 396 : 825 - 837
  • [47] Molecularly imprinted polymer as sorbent in micro-solid phase extraction of ochratoxin A in coffee, grape juice and urine
    Lee, Tien Ping
    Saad, Bahruddin
    Khayoon, Wejdan Shakir
    Salleh, Baharuddin
    TALANTA, 2012, 88 : 129 - 135
  • [48] Molecularly imprinted polymer-based, solid-phase extraction followed by liquid chromatographic determination of lacosamide in rat plasma
    Rao, R. Nageswara
    Sravan, B.
    Reddy, Ch. Krishna
    Meena, S.
    Prashamsa, J.
    Spoorthy, P.
    ANALYTICAL METHODS, 2014, 6 (09) : 3101 - 3107
  • [49] Imatinib assay by high-performance liquid chromatography in tandem mass spectrometry with solid-phase extraction in human plasma
    Moreno, Jose Maria
    Wojnicz, Aneta
    Steegman, Juan Luis
    Cano-Abad, Maria F.
    Ruiz-Nuno, Ana
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (04) : 502 - 508
  • [50] Determination of Benzodiazepines in Beef by Magnetic Solid Phase Extraction and High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Kuang, Huijuan
    Gan, Bei
    Guo, Liang
    Aguilar, Zoraida P.
    Xu, Hengyi
    ANALYTICAL LETTERS, 2016, 49 (04) : 499 - 510