Theoretical Evaluation of Energy Performance of a Vapour Compression Refrigeration System Using Sustainable Refrigerants

被引:0
|
作者
Shaik, Sharmas Vali [1 ]
Babu, T. P. Ashok [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Mangalore 575025, India
关键词
ALTERNATIVES; HCFC-22; REPLACEMENT;
D O I
10.1007/978-981-15-1616-0_35
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The chief goal of this present investigation is to evaluate performance parameters of various sustainable refrigerants as R22 alternatives. In this investigation apart from R290, R134a and R22, twelve mixture refrigerants were developed at various composition. Results showed that energy efficiency ratio (EER) of mixture refrigerant MR40 (R290/R134a 95/5 in mass%) (4.546) stood greatest among twelve investigated alternatives and it was closer to the EER of R22 (4.602). Compressor discharge temperature of MR40 was lower than R22 by 16.020C. Volumetric refrigeration capacity of MR40 (3424 kJ/m(3)) was relatively lesser than R22 (3801 kJ/m(3)). Power spent per ton of refrigeration (PPTR) of MR40 (0.773 kW/TR) stood lowest among twelve investigated alternatives and it was fairly greater than R22 (0.764 kW/TR). Global warming potential (GWP100) of MR40 (68) was very low compared to R22 (1760). Overall, performance of MR40 was closer to R22, when compared with all the twelve investigated alternatives, and hence, it might be treated as a suitable replacement to refrigerant R22.
引用
收藏
页码:361 / 370
页数:10
相关论文
共 50 条
  • [21] Irreversibility analysis of a compression refrigeration cycle using natural refrigerants for a sustainable future
    Kilicarslan, Ali
    INTERNATIONAL JOURNAL OF EXERGY, 2012, 10 (02) : 155 - 170
  • [22] Evaluation of a combined ejector-vapour-compression refrigeration system
    Sun, DW
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (04) : 333 - 342
  • [23] Energy recovery from a vapour compression refrigeration system using humidification dehumidification desalination
    Srithar, K.
    Rajaseenivasan, T.
    Arulmani, M.
    Gnanavel, R.
    Vivar, M.
    Fuentes, Manuel
    DESALINATION, 2018, 439 : 155 - 161
  • [24] Theoretical energy analysis of Cascade refrigeration system using low Global warming potential refrigerants
    Soni, Shubham
    Mishra, Punit
    Maheshwari, Govind
    Verma, Devendra S.
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 164 - 169
  • [25] Performance improvement of vapour compression refrigeration system using different phase changing materials
    Karthikeyan, A.
    Sivan, V. Aakhash
    Khaliq, Abdul Maher
    Anderson, A.
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 3540 - 3543
  • [26] Thermodynamic analysis of R422 series refrigerants as alternative refrigerants to HCFC22 in a vapour compression refrigeration system
    Arora, Akhilesh
    Sachdev, H. L.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (08) : 753 - 765
  • [27] PERFORMANCE EVALUATION OF CASCADE REFRIGERATION SYSTEMS USING DIFFERENT REFRIGERANTS
    Messineo, Antonio
    Panno, Domenico
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2012, 20 (03)
  • [28] Desalination using spray tower and vapour compression refrigeration system
    Refrigeration and Airconditioning Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai - 600 036, India
    不详
    不详
    不详
    不详
    Int. J. Nucl. Desalin., 2006, 1 (89-95):
  • [29] Performance evaluation of graphene-enhanced LPG in a vapour compression refrigeration system: An experimental approach
    Babarinde, T. O.
    Madyira, D. M.
    Mashinini, P. M.
    ENERGY REPORTS, 2022, 8 : 1226 - 1235
  • [30] ENERGY PERFORMANCE OF ECO-FRIENDLY RE170 AND R510A REFRIGERANTS AS ALTERNATIVES TO R134a IN VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Bolaji, B. O.
    Huan, Z.
    2012 PROCEEDINGS OF THE 9TH INDUSTRIAL AND COMMERCIAL USE OF ENERGY CONFERENCE (ICUE), 2012,