High-resolution magnetic resonance imaging of esophageal cancer using an endoluminal surface coil

被引:0
|
作者
Ozawa, S [1 ]
Imai, Y [1 ]
Ando, N [1 ]
Shinozaki, H [1 ]
Kitajima, M [1 ]
机构
[1] KEIO UNIV,SCH MED,DEPT SURG,TOKYO 160,JAPAN
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:165 / 175
页数:11
相关论文
共 50 条
  • [31] Accuracy of High-Resolution Magnetic Resonance Imaging in Preoperative Staging of Rectal Cancer
    Takayuki Akasu
    Gen Iinuma
    Masashi Takawa
    Seiichiro Yamamoto
    Yukio Muramatsu
    Noriyuki Moriyama
    Annals of Surgical Oncology, 2009, 16 : 2787 - 2794
  • [32] High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil
    Savukov, Igor
    Kim, Young Jin
    Newman, Shaun
    JOURNAL OF APPLIED PHYSICS, 2022, 132 (17)
  • [33] Surface Coil for Magnetic Resonance Imaging
    Ricardo Ferro, Beatriz Taimy
    Ramirez Aguilera, Andres
    Alvarez Guerra, Eloy Daniel
    REVISTA CUBANA DE INGENIERIA, 2015, 6 (01): : 13 - 21
  • [34] HIGH-RESOLUTION ENDOLUMINAL ULTRASONOGRAPHY IN THE STAGING OF ESOPHAGEAL-CARCINOMA
    MCLOUGHLIN, RF
    COOPERBERG, PL
    MATHIESON, JR
    STORDY, SN
    HALPARIN, LS
    JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (10) : 725 - 730
  • [35] Resonance Microwave Reflectometry for High-Resolution Surface Imaging
    Malyuskin, Oleksandr
    Fusco, Vincent
    2015 1st URSI Atlantic Radio Science Conference (URSI AT-RASC), 2015,
  • [36] Flexible 23-channel coil array for high-resolution magnetic resonance imaging at 3 Tesla
    Frass-Kriegl, Roberta
    de Lara, Lucia Isabel Navarro
    Pichler, Michael
    Sieg, Juergen
    Moser, Ewald
    Windischberger, Christian
    Laistler, Elmar
    PLOS ONE, 2018, 13 (11):
  • [37] Multi-objective optimization of gradient coil for benchtop magnetic resonance imaging system with high-resolution
    Wang Long-Qing
    Wang Wei-Min
    CHINESE PHYSICS B, 2014, 23 (02)
  • [38] Multi-objective optimization of gradient coil for benchtop magnetic resonance imaging system with high-resolution
    王龙庆
    王为民
    Chinese Physics B, 2014, 23 (02) : 593 - 600
  • [39] The localization of a conjunctivoscleral foreign body via high-resolution microscopy coil magnetic resonance imaging in a dog
    Lavaud, Arnold
    Lautenschlager, Ines E.
    Voelter, Katrin
    Ivan, Daniel
    Dennler, Matthias
    Pot, Simon A.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (05) : 703 - 709
  • [40] A micro planar coil for local high resolution Magnetic Resonance Imaging
    Takahashi, Hidetoshi
    Dohi, Tetsuji
    Matsumoto, Kiyoshi
    Shimoyama, Isao
    PROCEEDINGS OF THE IEEE TWENTIETH ANNUAL INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, VOLS 1 AND 2, 2007, : 786 - 789