Calibration of a 300-mm-aperture phase-shifting Fizeau interferometer

被引:39
|
作者
Oreb, BF
Farrant, DI
Walsh, CJ
Forbes, G
Fairman, PS
机构
[1] Telecommun & Ind Phys Commonwealth Sci & Ind Res, Lindfield, NSW, Australia
[2] Macquarie Univ, Dept Phys, N Ryde, NSW 2109, Australia
关键词
D O I
10.1364/AO.39.005161
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A 300-mm-aperture digital phase-shifting Fizeau interferometer has been developed in-house for precision metrology of optical components fabricated by the optical workshop at Telecommunications and Industrial Physics, Commonwealth Scientific and Industrial Research Organization. We describe the procedures used in the calibration of the instrument. A reference data file representing the deviations from flatness of the reference surface is generated, measurement uncertainty estimated, and aberrations in the instrument assessed. Measurements on 250-mm-diameter uncoated optical surfaces have consistently shown short-term repeatability of 0.3-nm rms from measurement to measurement and allowed for absolute characterization of these surfaces to within a few nanometers. (C) 2000 Optical Society of America OCIS codes: 120.3180, 120.3940, 120.6650, 120.5050, 120.4570, 120.4800.
引用
收藏
页码:5161 / 5171
页数:11
相关论文
共 50 条
  • [31] EVALUATION OF FIZEAU INTERFERENCES BY PHASE-SHIFTING INTERFEROMETRY
    NICOLAUS, RA
    OPTIK, 1991, 87 (01): : 23 - 26
  • [32] Phase-shifting shearing interferometer
    Griffin, DW
    OPTICS LETTERS, 2001, 26 (03) : 140 - 141
  • [33] Measurement of the surface form error of large aperture plane optical surfaces with a polarization phase-shifting liquid reference reflection Fizeau interferometer
    Chatterjee, Sanjib
    Kumar, Y. Pavan
    Singh, Rishipal
    Singh, Sarvendra
    APPLIED OPTICS, 2016, 55 (02) : 310 - 316
  • [34] Phase-shifting scatterplate interferometer
    North-Morris, M
    Wyant, JC
    ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY 2000, 2000, 4231 : 59 - 66
  • [35] Evaluation of Measurement Uncertainty for Absolute Flatness Measurement by Using Fizeau Interferometer with Phase-Shifting Capability
    Girija Moona
    Rina Sharma
    Usha Kiran
    K. P. Chaudhary
    MAPAN, 2014, 29 : 261 - 267
  • [36] Calibration method to characterize the accuracy of phase-shifting point diffraction interferometer
    Liu, Ke
    Li, Yanqiu
    Wang, Hai
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [37] Evaluation of Measurement Uncertainty for Absolute Flatness Measurement by Using Fizeau Interferometer with Phase-Shifting Capability
    Moona, G.
    Sharma, R.
    Kiran, U.
    Chaudhary, K. P.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2014, 29 (04): : 261 - 267
  • [38] PHASE-DETERMINATION OF FIZEAU INTERFERENCES BY PHASE-SHIFTING INTERFEROMETRY
    BONSCH, G
    BOHME, H
    OPTIK, 1989, 82 (04): : 161 - 164
  • [39] Research on phase-shifting characteristic of retarder array in simultaneous phase-shifting interferometer
    School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing
    Jiangsu
    210094, China
    不详
    Jiangsu
    210042, China
    Guangxue Xuebao, 4
  • [40] Correlated errors in phase-shifting laser Fizeau interferometry
    de Groot, Peter J.
    APPLIED OPTICS, 2014, 53 (19) : 4334 - 4342